TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Temperature & Humidity Report | 1 to 1440 (Default) |
Adjustable from 1 - 1440 in minutes (Hexadecimal: 0x01 - 0x5A0) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | Waiting time between two motion alarms | 10 to 3600 (Default) |
Adjustable from 10 - 3600 in seconds (Hexadecimal: 0x10 - 0xE10) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 2 | Reset waiting time after motion alarm | 10 to 3600 (Default) |
Adjustable from 10 - 3600 in seconds (Hexadecimal: 0x10 - 0xE10) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Temperature report threshold | 0 | The value 0 deactivates the temperature report. (Hexadecimal: 0x00) | |
1 to 10 (Default) |
Adjustable from 1 - 10 in 0.5° steps (e.g. 5 = 2.5°, Hexadecimal: 0x01 - 0x0A) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Humidity report threshold | 0 | The value 0 deactivates the temperature report. (Hexadecimal: 0x00) | |
1 to 10 (Default) |
Adjustable from 1 - 10 in 5% steps (e.g. 5 = 25%, Hexadecimal: 0x01 - 0x0A) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | LED status | 0 | 0 = LED deactivated (Hexadecimal: 0x00) | |
1 (Default) |