There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Relay Switch Quinto (HE-RS01)

Z-Wave Certification Number: ZC12-20040046


Parameter Number

Parameter Size

Parameter Name

Description

1 1 TIME CORRECTION Time correction by controller

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Switch off auto-correction
1 (2)   If TPS05 is connected to a Z-Wave gateway, the time and day will be periodically polled and corrected from the gateway

Parameter Number

Parameter Size

Parameter Name

Description

10 1 RELAY5 CONTROL SOURCE Relay 5 control source

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 5 No No No

Value

 

Description

0   Controlled by gateway or associated device
1   Controlled by touch button N1 (Top Left)
2   Controlled by touch button N2 (Top Right)
3   Controlled by touch button N3 (Bottom Left)
4   Controlled by touch button N4 (Bottom Right)
5   Controlled by touch button N5 (Center)

Parameter Number

Parameter Size

Parameter Name

Description

11 1 HOLD1 CONTROL MODE Hold control mode for touch button 1

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

Value

 

Description

0   Hold function is disabled
1   Operate like click
2   When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch).
3   When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch).

Parameter Number

Parameter Size

Parameter Name

Description

12 1 HOLD2 CONTROL MODE Hold control mode for touch button 2

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

Value

 

Description

0   Hold function is disabled
1   Operate like click
2   When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch).
3   When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch).

Parameter Number

Parameter Size

Parameter Name

Description

13 1 HOLD3 CONTROL MODE Hold control mode for touch button 3

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

Value

 

Description

0   Hold function is disabled
1   Operate like click
2   When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch).
3   When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch).

Parameter Number

Parameter Size

Parameter Name

Description

14 1 HOLD4 CONTROL MODE Hold control mode for touch button 4

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

Value

 

Description

0   Hold function is disabled
1   Operate like click
2   When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch).
3   When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch).

Parameter Number

Parameter Size

Parameter Name

Description

15 1 HOLD5 CONTROL MODE Hold control mode for touch button 5

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

Value

 

Description

0   Hold function is disabled
1   Operate like click
2   When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch).
3   When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch).

Parameter Number

Parameter Size

Parameter Name

Description

16 1 CLICK1 CONTROL MODE Click control mode for touch button 1

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 6 No No No

Value

 

Description

0   Click function disabled
1   Relay inverts state (toggles ON to OFF, OFF to ON).
2   Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state.
3   Relay switches to ON state only.
4   Relay switches to OFF state only.
5   Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39.
6   Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39.

Parameter Number

Parameter Size

Parameter Name

Description

17 1 CLICK2 CONTROL MODE Click control mode for touch button 2

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 6 No No No

Value

 

Description

0   Click function disabled
1   Relay inverts state (toggles ON to OFF, OFF to ON).
2   Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state.
3   Relay switches to ON state only.
4   Relay switches to OFF state only.
5   Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39.
6   Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39.

Parameter Number

Parameter Size

Parameter Name

Description

18 1 CLICK3 CONTROL MODE Click control mode for touch button 3

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 6 No No No

Value

 

Description

0   Click function disabled
1   Relay inverts state (toggles ON to OFF, OFF to ON).
2   Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state.
3   Relay switches to ON state only.
4   Relay switches to OFF state only.
5   Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39.
6   Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39.

Parameter Number

Parameter Size

Parameter Name

Description

19 1 CLICK4 CONTROL MODE Click control mode for touch button 4

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 6 No No No

Value

 

Description

0   Click function disabled
1   Relay inverts state (toggles ON to OFF, OFF to ON).
2   Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state.
3   Relay switches to ON state only.
4   Relay switches to OFF state only.
5   Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39.
6   Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39.

Parameter Number

Parameter Size

Parameter Name

Description

2 1 WEEKDAY The day of the week (starting from Monday)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 7 No No No

Bit (Value)

 

Description

1 (2)   Monday
2 (4)   Tuesday
3 (8)   Wednesday
4 (16)   Thursday
5 (32)   Friday
6 (64)   Saturday
7 (128)   Sunday

Parameter Number

Parameter Size

Parameter Name

Description

20 1 CLICK5 CONTROL MODE Click control mode for touch button 5

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 6 No No No

Value

 

Description

0   Click function disabled
1   Relay inverts state (toggles ON to OFF, OFF to ON).
2   Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state.
3   Relay switches to ON state only.
4   Relay switches to OFF state only.
5   Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39.
6   Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39.

Parameter Number

Parameter Size

Parameter Name

Description

21 2 RELAY1 TIMER DURATION Timer mode duration for button 1. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 30). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 43200 No No No

Value

 

Description

0   Timer mode duration in seconds

Parameter Number

Parameter Size

Parameter Name

Description

22 2 RELAY2 TIMER DURATION Timer mode duration for button 2. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 31). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 43200 No No No

Value

 

Description

0   Timer mode duration in seconds

Parameter Number

Parameter Size

Parameter Name

Description

23 2 RELAY3 TIMER DURATION Timer mode duration for button 3. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 32). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 43200 No No No

Value

 

Description

0   Timer mode duration in seconds

Parameter Number

Parameter Size

Parameter Name

Description

24 2 RELAY4 TIMER DURATION Timer mode duration for button 4. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 33). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 43200 No No No

Value

 

Description

0   Timer mode duration in seconds

Parameter Number

Parameter Size

Parameter Name

Description

25 2 RELAY5 TIMER DURATION Timer mode duration for button 5. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 34). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 43200 No No No

Value

 

Description

0   Timer mode duration in seconds

Parameter Number

Parameter Size

Parameter Name

Description

26 1 RELAY INVERSE GROUP1 Group 1 relay inverse mode. The valid values are the following: 0, 12, 13, 14, 15, 21, 23, 24, 25, 31, 32, 34, 35, 41, 42, 43, 45, 51, 52, 53, 54

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 54 No No No

Bit (Value)

 

Description

0 (1)   Inverse function is disabled
12 (4096)   Relays N1 and N2 will operate in inverse mode.
13 (8192)   Relays N1 and N3 will operate in inverse mode.
14 (16384)   Relays N1 and N4 will operate in inverse mode.
15 (32768)   Relays N1 and N5 will operate in inverse mode.
21 (2097152)   Relays N2 and N1 will operate in inverse mode.
23 (8388608)   Relays N2 and N3 will operate in inverse mode.
24 (16777216)   Relays N2 and N4 will operate in inverse mode.
25 (33554432)   Relays N2 and N5 will operate in inverse mode.
31 (2147483648)   Relays N3 and N1 will operate in inverse mode.
32 (4294967296)   Relays N3 and N2 will operate in inverse mode.
34 (17179869184)   Relays N3 and N4 will operate in inverse mode.
35 (34359738368)   Relays N3 and N5 will operate in inverse mode.
41 (2199023255552)   Relays N4 and N1 will operate in inverse mode.
42 (4398046511104)   Relays N4 and N2 will operate in inverse mode.
43 (8796093022208)   Relays N4 and N3 will operate in inverse mode.
45 (35184372088832)   Relays N4 and N5 will operate in inverse mode.
51 (2.25179981368525E+15)   Relays N5 and N1 will operate in inverse mode.
52 (4.5035996273705E+15)   Relays N5 and N2 will operate in inverse mode.
53 (9.00719925474099E+15)   Relays N5 and N3 will operate in inverse mode.
54 (1.8014398509482E+16)   Relays N5 and N4 will operate in inverse mode.

Parameter Number

Parameter Size

Parameter Name

Description

27 1 RELAY INVERSE GROUP2 Group 2 relay inverse mode. The valid values are the following: 0, 12, 13, 14, 15, 21, 23, 24, 25, 31, 32, 34, 35, 41, 42, 43, 45, 51, 52, 53, 54

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 54 No No No

Bit (Value)

 

Description

0 (1)   Inverse function is disabled
12 (4096)   Relays N1 and N2 will operate in inverse mode.
13 (8192)   Relays N1 and N3 will operate in inverse mode.
14 (16384)   Relays N1 and N4 will operate in inverse mode.
15 (32768)   Relays N1 and N5 will operate in inverse mode.
21 (2097152)   Relays N2 and N1 will operate in inverse mode.
23 (8388608)   Relays N2 and N3 will operate in inverse mode.
24 (16777216)   Relays N2 and N4 will operate in inverse mode.
25 (33554432)   Relays N2 and N5 will operate in inverse mode.
31 (2147483648)   Relays N3 and N1 will operate in inverse mode.
32 (4294967296)   Relays N3 and N2 will operate in inverse mode.
34 (17179869184)   Relays N3 and N4 will operate in inverse mode.
35 (34359738368)   Relays N3 and N5 will operate in inverse mode.
41 (2199023255552)   Relays N4 and N1 will operate in inverse mode.
42 (4398046511104)   Relays N4 and N2 will operate in inverse mode.
43 (8796093022208)   Relays N4 and N3 will operate in inverse mode.
45 (35184372088832)   Relays N4 and N5 will operate in inverse mode.
51 (2.25179981368525E+15)   Relays N5 and N1 will operate in inverse mode.
52 (4.5035996273705E+15)   Relays N5 and N2 will operate in inverse mode.
53 (9.00719925474099E+15)   Relays N5 and N3 will operate in inverse mode.
54 (1.8014398509482E+16)   Relays N5 and N4 will operate in inverse mode.

Parameter Number

Parameter Size

Parameter Name

Description

28 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

29 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 HOUR Time Hour

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 23 No No No

Value

 

Description

0   Time Hour in 24 hour format

Parameter Number

Parameter Size

Parameter Name

Description

30 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

31 4 RELAY CONTROL SCENARIO1 Relays control by sensors Group 1 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

32 4 RELAY CONTROL SCENARIO2 Relays control by sensors Group 2 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

33 4 RELAY CONTROL SCENARIO3 Relays control by sensors Group 3 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

34 4 RELAY CONTROL SCENARIO4 Relays control by sensors Group 4 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

35 4 RELAY CONTROL SCENARIO5 Relays control by sensors Group 5 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

36 4 RELAY CONTROL SCENARIO6 Relays control by sensors Group 6 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

37 4 RELAY CONTROL SCENARIO7 Relays control by sensors Group 7. 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

38 4 RELAY CONTROL SCENARIO8 Relays control by sensors Group 8 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

39 4 RELAY CONTROL SCENARIO9 Relays control by sensors Group 9 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

4 1 MINUTE Time Minute

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 59 No No No

Value

 

Description

0   Manual adjustment of time minutes (60 minutes)

Parameter Number

Parameter Size

Parameter Name

Description

40 4 RELAY CONTROL SCENARIO10 Relays control by sensors Group 10. 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 53112359 No No No

Value

 

Description

0   Scenario function is disabled
1   Behavior according to the encoded scenario

Parameter Number

Parameter Size

Parameter Name

Description

41 2 RELAY1 LOAD POWER Power load consumption (in Watts) Relay channel 1 in order to calculate total energy consumption relative to the time each relay is ON.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1100 No No No

Value

 

Description

0   Power load consumption (in Watts)

Parameter Number

Parameter Size

Parameter Name

Description

42 2 RELAY2 LOAD POWER Power load consumption (in Watts) Relay channel 2 in order to calculate total energy consumption relative to the time each relay is ON.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1100 No No No

Value

 

Description

0   Power load consumption (in Watts)

Parameter Number

Parameter Size

Parameter Name

Description

43 2 RELAY3 LOAD POWER Power load consumption (in Watts) Relay channel 3 in order to calculate total energy consumption relative to the time each relay is ON.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1100 No No No

Value

 

Description

0   Power load consumption (in Watts)

Parameter Number

Parameter Size

Parameter Name

Description

44 2 RELAY4 LOAD POWER Power load consumption (in Watts) Relay channel 4 in order to calculate total energy consumption relative to the time each relay is ON.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1100 No No No

Value

 

Description

0   Power load consumption (in Watts)

Parameter Number

Parameter Size

Parameter Name

Description

45 2 RELAY5 LOAD POWER Power load consumption (in Watts) Relay channel 5 in order to calculate total energy consumption relative to the time each relay is ON.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1100 No No No

Value

 

Description

0   Power load consumption (in Watts)

Parameter Number

Parameter Size

Parameter Name

Description

46 1 S1 ASSOCIATION MODE Associations mode for external input S1 . These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices.
1 (2)   On each hold event, the “UP (brighten)” command will be sent to associated devices.
2 (4)   On each hold event, the “DOWN (dim)” command will be sent to associated devices.

Parameter Number

Parameter Size

Parameter Name

Description

47 1 S2 ASSOCIATION MODE Associations mode for external input S2. These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices.
1 (2)   On each hold event, the “UP (brighten)” command will be sent to associated devices.
2 (4)   On each hold event, the “DOWN (dim)” command will be sent to associated devices.

Parameter Number

Parameter Size

Parameter Name

Description

48 1 S3 ASSOCIATION MODE Associations mode for external input S3. These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices.
1 (2)   On each hold event, the “UP (brighten)” command will be sent to associated devices.
2 (4)   On each hold event, the “DOWN (dim)” command will be sent to associated devices.

Parameter Number

Parameter Size

Parameter Name

Description

49 1 S4 ASSOCIATION MODE Associations mode for external input S4. These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices.
1 (2)   On each hold event, the “UP (brighten)” command will be sent to associated devices.
2 (4)   On each hold event, the “DOWN (dim)” command will be sent to associated devices.

Parameter Number

Parameter Size

Parameter Name

Description

5 1 METER REPORT INTERVAL Energy Consumption Meter Consecutive Report Interval, minutes

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 1 120 No No No

Value

 

Description

1   Energy Consumption Meter Consecutive Report Interval in Minutes

Parameter Number

Parameter Size

Parameter Name

Description

50 1 S5 ASSOCIATION MODE Associations mode for external input S5. These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices.
1 (2)   On each hold event, the “UP (brighten)” command will be sent to associated devices.
2 (4)   On each hold event, the “DOWN (dim)” command will be sent to associated devices.

Parameter Number

Parameter Size

Parameter Name

Description

51 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

52 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

53 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

54 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

55 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

56 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

57 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

58 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

59 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

6 1 RELAY1 CONTROL SOURCE Relay 1 control source

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 5 No No No

Value

 

Description

0   Controlled by gateway or associated device
1   Controlled by touch button N1 (Top Left)
2   Controlled by touch button N2 (Top Right)
3   Controlled by touch button N3 (Bottom Left)
4   Controlled by touch button N4 (Bottom Right)
5   Controlled by touch button N5 (Center)

Parameter Number

Parameter Size

Parameter Name

Description

60 1 RESERVED Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.

Parameter Number

Parameter Size

Parameter Name

Description

7 1 RELAY2 CONTROL SOURCE Relay 2 control source

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 5 No No No

Value

 

Description

0   Controlled by gateway or associated device
1   Controlled by touch button N1 (Top Left)
2   Controlled by touch button N2 (Top Right)
3   Controlled by touch button N3 (Bottom Left)
4   Controlled by touch button N4 (Bottom Right)
5   Controlled by touch button N5 (Center)

Parameter Number

Parameter Size

Parameter Name

Description

8 1 RELAY3 CONTROL SOURCE Relay 3 control source

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 5 No No No

Value

 

Description

0   Controlled by gateway or associated device
1   Controlled by touch button N1 (Top Left)
2   Controlled by touch button N2 (Top Right)
3   Controlled by touch button N3 (Bottom Left)
4   Controlled by touch button N4 (Bottom Right)
5   Controlled by touch button N5 (Center)

Parameter Number

Parameter Size

Parameter Name

Description

9 1 RELAY4 CONTROL SOURCE Relay 4 control source

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

4 0 5 No No No

Value

 

Description

0   Controlled by gateway or associated device
1   Controlled by touch button N1 (Top Left)
2   Controlled by touch button N2 (Top Right)
3   Controlled by touch button N3 (Bottom Left)
4   Controlled by touch button N4 (Bottom Right)
5   Controlled by touch button N5 (Center)