Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | TIME CORRECTION | Time correction by controller | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Switch off auto-correction | ||||
1 (2) | If TPS05 is connected to a Z-Wave gateway, the time and day will be periodically polled and corrected from the gateway | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | RELAY5 CONTROL SOURCE | Relay 5 control source | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 5 | No | No | No |
Value |
Description |
||||
0 | Controlled by gateway or associated device | ||||
1 | Controlled by touch button N1 (Top Left) | ||||
2 | Controlled by touch button N2 (Top Right) | ||||
3 | Controlled by touch button N3 (Bottom Left) | ||||
4 | Controlled by touch button N4 (Bottom Right) | ||||
5 | Controlled by touch button N5 (Center) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | HOLD1 CONTROL MODE | Hold control mode for touch button 1 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Hold function is disabled | ||||
1 | Operate like click | ||||
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). | ||||
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | HOLD2 CONTROL MODE | Hold control mode for touch button 2 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Hold function is disabled | ||||
1 | Operate like click | ||||
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). | ||||
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | HOLD3 CONTROL MODE | Hold control mode for touch button 3 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Hold function is disabled | ||||
1 | Operate like click | ||||
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). | ||||
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 1 | HOLD4 CONTROL MODE | Hold control mode for touch button 4 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Hold function is disabled | ||||
1 | Operate like click | ||||
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). | ||||
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | HOLD5 CONTROL MODE | Hold control mode for touch button 5 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Hold function is disabled | ||||
1 | Operate like click | ||||
2 | When the button is held the relay output state is ON, as soon as the button is released the relay output state changes to OFF (momentary switch). | ||||
3 | When the button is held the relay output state is OFF, as soon as the button is released the relay output state changes to ON (momentary switch). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | CLICK1 CONTROL MODE | Click control mode for touch button 1 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 6 | No | No | No |
Value |
Description |
||||
0 | Click function disabled | ||||
1 | Relay inverts state (toggles ON to OFF, OFF to ON). | ||||
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. | ||||
3 | Relay switches to ON state only. | ||||
4 | Relay switches to OFF state only. | ||||
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. | ||||
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 1 | CLICK2 CONTROL MODE | Click control mode for touch button 2 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 6 | No | No | No |
Value |
Description |
||||
0 | Click function disabled | ||||
1 | Relay inverts state (toggles ON to OFF, OFF to ON). | ||||
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. | ||||
3 | Relay switches to ON state only. | ||||
4 | Relay switches to OFF state only. | ||||
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. | ||||
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | CLICK3 CONTROL MODE | Click control mode for touch button 3 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 6 | No | No | No |
Value |
Description |
||||
0 | Click function disabled | ||||
1 | Relay inverts state (toggles ON to OFF, OFF to ON). | ||||
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. | ||||
3 | Relay switches to ON state only. | ||||
4 | Relay switches to OFF state only. | ||||
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. | ||||
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 1 | CLICK4 CONTROL MODE | Click control mode for touch button 4 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 6 | No | No | No |
Value |
Description |
||||
0 | Click function disabled | ||||
1 | Relay inverts state (toggles ON to OFF, OFF to ON). | ||||
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. | ||||
3 | Relay switches to ON state only. | ||||
4 | Relay switches to OFF state only. | ||||
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. | ||||
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | WEEKDAY | The day of the week (starting from Monday) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 7 | No | No | No |
Bit (Value) |
Description |
||||
1 (2) | Monday | ||||
2 (4) | Tuesday | ||||
3 (8) | Wednesday | ||||
4 (16) | Thursday | ||||
5 (32) | Friday | ||||
6 (64) | Saturday | ||||
7 (128) | Sunday | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | CLICK5 CONTROL MODE | Click control mode for touch button 5 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 6 | No | No | No |
Value |
Description |
||||
0 | Click function disabled | ||||
1 | Relay inverts state (toggles ON to OFF, OFF to ON). | ||||
2 | Relay inverts state (toggles ON to OFF, OFF to ON) according to the button backlight state. | ||||
3 | Relay switches to ON state only. | ||||
4 | Relay switches to OFF state only. | ||||
5 | Timer: On>Off Mode: Relay output switches to ON state (contacts are closed) then after a specified time switches back to OFF state (contacts are open). The time is specified in parameters 35-39. | ||||
6 | Timer: OFF>ON Mode: Relay output switches to OFF state (contacts are open) then after a specified time switches back to ON state (contacts are closed). The time is specified in Parameters 35-39. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
21 | 2 | RELAY1 TIMER DURATION | Timer mode duration for button 1. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 30). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 43200 | No | No | No |
Value |
Description |
||||
0 | Timer mode duration in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
22 | 2 | RELAY2 TIMER DURATION | Timer mode duration for button 2. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 31). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 43200 | No | No | No |
Value |
Description |
||||
0 | Timer mode duration in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
23 | 2 | RELAY3 TIMER DURATION | Timer mode duration for button 3. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 32). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 43200 | No | No | No |
Value |
Description |
||||
0 | Timer mode duration in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
24 | 2 | RELAY4 TIMER DURATION | Timer mode duration for button 4. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 33). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 43200 | No | No | No |
Value |
Description |
||||
0 | Timer mode duration in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
25 | 2 | RELAY5 TIMER DURATION | Timer mode duration for button 5. This parameter specifies the duration in seconds for the Timer mode (value 5 or 6 in Parameters 34). Press the button and the relay output goes to ON/OFF for the specified time then changes back to OFF/ON. This function can be used to open/close garage doors, blinds, curtains, etc. or to turn attached devices like security OFF for a short time. The time values can be configured from 0 to 43200 sec (12 hours). Note: If the parameter value is set to “0” it will operate as a short contact (about 0.5 sec). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 43200 | No | No | No |
Value |
Description |
||||
0 | Timer mode duration in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
26 | 1 | RELAY INVERSE GROUP1 | Group 1 relay inverse mode. The valid values are the following: 0, 12, 13, 14, 15, 21, 23, 24, 25, 31, 32, 34, 35, 41, 42, 43, 45, 51, 52, 53, 54 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 54 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Inverse function is disabled | ||||
12 (4096) | Relays N1 and N2 will operate in inverse mode. | ||||
13 (8192) | Relays N1 and N3 will operate in inverse mode. | ||||
14 (16384) | Relays N1 and N4 will operate in inverse mode. | ||||
15 (32768) | Relays N1 and N5 will operate in inverse mode. | ||||
21 (2097152) | Relays N2 and N1 will operate in inverse mode. | ||||
23 (8388608) | Relays N2 and N3 will operate in inverse mode. | ||||
24 (16777216) | Relays N2 and N4 will operate in inverse mode. | ||||
25 (33554432) | Relays N2 and N5 will operate in inverse mode. | ||||
31 (2147483648) | Relays N3 and N1 will operate in inverse mode. | ||||
32 (4294967296) | Relays N3 and N2 will operate in inverse mode. | ||||
34 (17179869184) | Relays N3 and N4 will operate in inverse mode. | ||||
35 (34359738368) | Relays N3 and N5 will operate in inverse mode. | ||||
41 (2199023255552) | Relays N4 and N1 will operate in inverse mode. | ||||
42 (4398046511104) | Relays N4 and N2 will operate in inverse mode. | ||||
43 (8796093022208) | Relays N4 and N3 will operate in inverse mode. | ||||
45 (35184372088832) | Relays N4 and N5 will operate in inverse mode. | ||||
51 (2.25179981368525E+15) | Relays N5 and N1 will operate in inverse mode. | ||||
52 (4.5035996273705E+15) | Relays N5 and N2 will operate in inverse mode. | ||||
53 (9.00719925474099E+15) | Relays N5 and N3 will operate in inverse mode. | ||||
54 (1.8014398509482E+16) | Relays N5 and N4 will operate in inverse mode. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
27 | 1 | RELAY INVERSE GROUP2 | Group 2 relay inverse mode. The valid values are the following: 0, 12, 13, 14, 15, 21, 23, 24, 25, 31, 32, 34, 35, 41, 42, 43, 45, 51, 52, 53, 54 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 54 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Inverse function is disabled | ||||
12 (4096) | Relays N1 and N2 will operate in inverse mode. | ||||
13 (8192) | Relays N1 and N3 will operate in inverse mode. | ||||
14 (16384) | Relays N1 and N4 will operate in inverse mode. | ||||
15 (32768) | Relays N1 and N5 will operate in inverse mode. | ||||
21 (2097152) | Relays N2 and N1 will operate in inverse mode. | ||||
23 (8388608) | Relays N2 and N3 will operate in inverse mode. | ||||
24 (16777216) | Relays N2 and N4 will operate in inverse mode. | ||||
25 (33554432) | Relays N2 and N5 will operate in inverse mode. | ||||
31 (2147483648) | Relays N3 and N1 will operate in inverse mode. | ||||
32 (4294967296) | Relays N3 and N2 will operate in inverse mode. | ||||
34 (17179869184) | Relays N3 and N4 will operate in inverse mode. | ||||
35 (34359738368) | Relays N3 and N5 will operate in inverse mode. | ||||
41 (2199023255552) | Relays N4 and N1 will operate in inverse mode. | ||||
42 (4398046511104) | Relays N4 and N2 will operate in inverse mode. | ||||
43 (8796093022208) | Relays N4 and N3 will operate in inverse mode. | ||||
45 (35184372088832) | Relays N4 and N5 will operate in inverse mode. | ||||
51 (2.25179981368525E+15) | Relays N5 and N1 will operate in inverse mode. | ||||
52 (4.5035996273705E+15) | Relays N5 and N2 will operate in inverse mode. | ||||
53 (9.00719925474099E+15) | Relays N5 and N3 will operate in inverse mode. | ||||
54 (1.8014398509482E+16) | Relays N5 and N4 will operate in inverse mode. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
28 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
29 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | HOUR | Time Hour | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 23 | No | No | No |
Value |
Description |
||||
0 | Time Hour in 24 hour format | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
30 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
31 | 4 | RELAY CONTROL SCENARIO1 | Relays control by sensors Group 1 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
32 | 4 | RELAY CONTROL SCENARIO2 | Relays control by sensors Group 2 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
33 | 4 | RELAY CONTROL SCENARIO3 | Relays control by sensors Group 3 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
34 | 4 | RELAY CONTROL SCENARIO4 | Relays control by sensors Group 4 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
35 | 4 | RELAY CONTROL SCENARIO5 | Relays control by sensors Group 5 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
36 | 4 | RELAY CONTROL SCENARIO6 | Relays control by sensors Group 6 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
37 | 4 | RELAY CONTROL SCENARIO7 | Relays control by sensors Group 7. 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
38 | 4 | RELAY CONTROL SCENARIO8 | Relays control by sensors Group 8 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
39 | 4 | RELAY CONTROL SCENARIO9 | Relays control by sensors Group 9 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | MINUTE | Time Minute | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 59 | No | No | No |
Value |
Description |
||||
0 | Manual adjustment of time minutes (60 minutes) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 4 | RELAY CONTROL SCENARIO10 | Relays control by sensors Group 10. 0, 10000000 … 53112359 Encoded as 8 digit value (ABCDEFGH): A: Relay number (1.. 5) B: Control Mode (0-Temperature Sensor, 1-Humidity Sensor, 2-Light Sensor, 3-Time control) C: State change condition relative to the value in HGFE Value field ( 0-Lower than, 1-Higher than) D: State Change, 0- Switch OFF, 1- Switch ON EFGH: Condition Value Sensor Value for Control modes 0-2 Time Of Day for Control mode 3. EF represents Hour (0..23), GH represents Minutes (0..59) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 53112359 | No | No | No |
Value |
Description |
||||
0 | Scenario function is disabled | ||||
1 | Behavior according to the encoded scenario | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
41 | 2 | RELAY1 LOAD POWER | Power load consumption (in Watts) Relay channel 1 in order to calculate total energy consumption relative to the time each relay is ON. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1100 | No | No | No |
Value |
Description |
||||
0 | Power load consumption (in Watts) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
42 | 2 | RELAY2 LOAD POWER | Power load consumption (in Watts) Relay channel 2 in order to calculate total energy consumption relative to the time each relay is ON. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1100 | No | No | No |
Value |
Description |
||||
0 | Power load consumption (in Watts) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
43 | 2 | RELAY3 LOAD POWER | Power load consumption (in Watts) Relay channel 3 in order to calculate total energy consumption relative to the time each relay is ON. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1100 | No | No | No |
Value |
Description |
||||
0 | Power load consumption (in Watts) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
44 | 2 | RELAY4 LOAD POWER | Power load consumption (in Watts) Relay channel 4 in order to calculate total energy consumption relative to the time each relay is ON. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1100 | No | No | No |
Value |
Description |
||||
0 | Power load consumption (in Watts) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
45 | 2 | RELAY5 LOAD POWER | Power load consumption (in Watts) Relay channel 5 in order to calculate total energy consumption relative to the time each relay is ON. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1100 | No | No | No |
Value |
Description |
||||
0 | Power load consumption (in Watts) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
46 | 1 | S1 ASSOCIATION MODE | Associations mode for external input S1 . These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices. | ||||
1 (2) | On each hold event, the “UP (brighten)” command will be sent to associated devices. | ||||
2 (4) | On each hold event, the “DOWN (dim)” command will be sent to associated devices. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
47 | 1 | S2 ASSOCIATION MODE | Associations mode for external input S2. These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices. | ||||
1 (2) | On each hold event, the “UP (brighten)” command will be sent to associated devices. | ||||
2 (4) | On each hold event, the “DOWN (dim)” command will be sent to associated devices. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
48 | 1 | S3 ASSOCIATION MODE | Associations mode for external input S3. These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices. | ||||
1 (2) | On each hold event, the “UP (brighten)” command will be sent to associated devices. | ||||
2 (4) | On each hold event, the “DOWN (dim)” command will be sent to associated devices. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
49 | 1 | S4 ASSOCIATION MODE | Associations mode for external input S4. These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices. | ||||
1 (2) | On each hold event, the “UP (brighten)” command will be sent to associated devices. | ||||
2 (4) | On each hold event, the “DOWN (dim)” command will be sent to associated devices. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | METER REPORT INTERVAL | Energy Consumption Meter Consecutive Report Interval, minutes | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 1 | 120 | No | No | No |
Value |
Description |
||||
1 | Energy Consumption Meter Consecutive Report Interval in Minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
50 | 1 | S5 ASSOCIATION MODE | Associations mode for external input S5. These parameters are intended for use when Multilevel Switch Group Associations (Groups 3, 5, 7, 9 & 11) have been activated. They define the logic of values changing if one of the buttons on switch connected to external inputs S1-S5 has been held for more than one second. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | On each hold event, “UP (brighten)” and “DOWN (dim)” command will be alternately sent to associated devices. | ||||
1 (2) | On each hold event, the “UP (brighten)” command will be sent to associated devices. | ||||
2 (4) | On each hold event, the “DOWN (dim)” command will be sent to associated devices. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
51 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
52 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
53 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
54 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
55 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
56 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
57 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
58 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
59 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | RELAY1 CONTROL SOURCE | Relay 1 control source | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 5 | No | No | No |
Value |
Description |
||||
0 | Controlled by gateway or associated device | ||||
1 | Controlled by touch button N1 (Top Left) | ||||
2 | Controlled by touch button N2 (Top Right) | ||||
3 | Controlled by touch button N3 (Bottom Left) | ||||
4 | Controlled by touch button N4 (Bottom Right) | ||||
5 | Controlled by touch button N5 (Center) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
60 | 1 | RESERVED | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | RELAY2 CONTROL SOURCE | Relay 2 control source | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 5 | No | No | No |
Value |
Description |
||||
0 | Controlled by gateway or associated device | ||||
1 | Controlled by touch button N1 (Top Left) | ||||
2 | Controlled by touch button N2 (Top Right) | ||||
3 | Controlled by touch button N3 (Bottom Left) | ||||
4 | Controlled by touch button N4 (Bottom Right) | ||||
5 | Controlled by touch button N5 (Center) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | RELAY3 CONTROL SOURCE | Relay 3 control source | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 0 | 5 | No | No | No |
Value |
Description |
||||
0 | Controlled by gateway or associated device | ||||
1 | Controlled by touch button N1 (Top Left) | ||||
2 | Controlled by touch button N2 (Top Right) | ||||
3 | Controlled by touch button N3 (Bottom Left) | ||||
4 | Controlled by touch button N4 (Bottom Right) | ||||
5 | Controlled by touch button N5 (Center) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | RELAY4 CONTROL SOURCE | Relay 4 control source | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
4 | 0 | 5 | No | No | No |
Value |
Description |
||||
0 | Controlled by gateway or associated device | ||||
1 | Controlled by touch button N1 (Top Left) | ||||
2 | Controlled by touch button N2 (Top Right) | ||||
3 | Controlled by touch button N3 (Bottom Left) | ||||
4 | Controlled by touch button N4 (Bottom Right) | ||||
5 | Controlled by touch button N5 (Center) | ||||