There are over 4057 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Switch 7 (ZWA023-A)

Z-Wave Certification Number: ZC12-20050064


Parameter Number

Parameter Size

Parameter Name

Description

1 1 LED Setting This parameter is used to change the reaction of LED setting. 0 - Disable LED completely. LED will only be used for network operation indicator, such as inclusion, exclusion, factory reset.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable LED completely
1 (2)   Turn on between particular times only (act as night light).
2 (4)   Display On/Off Status.

Parameter Number

Parameter Size

Parameter Name

Description

10 2 Over-load Protection Turn off switch when current of load connected bypasses the maximum allowed power regardless of always on setting. Unit W. 0 - disable overload protection 1~1800 - When watt detected above this setting value, the switch will be turned off immediately. And an over-load notification will be sent.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1800 0 1800 No No No

Value

 

Description

0   disable overload protection
1   When watt detected above this setting value, the switch will be turned off immediately. And an over-load notification will be sent.

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Over-voltage Protection This parameter is used to set the over-voltage protect value, unit V. 0 - disable over-voltage protection 95~255 - When voltage detected above this setting value, the switch will be turned off immediately. And an over-voltage notification will be sent.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

135 0 255 No No No

Value

 

Description

0   disable over-voltage protection
1   When voltage detected above this setting value, the switch will be turned off immediately. And an over-voltage notification will be sent.

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Threshold Check Time Set the period of threshold check. Unit second. 0 - disable all threshold settings 1~255 - set in seconds on how fast device checks for threshold settings

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 255 No No No

Value

 

Description

0   disable all threshold settings
1   set in seconds on how fast device checks for threshold settings

Parameter Number

Parameter Size

Parameter Name

Description

2 4 Night Light On Time This parameter is used to configure the Night Light on time. User can use Color CC to change the Night Light color(default Red). Only useful when parameter 1 is set to 1. RR = Reserved HH = Hours MM = Minutes SS = Seconds Default = 0x00180000 means 6pm

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1572864 0 2316633 No No No

Value

 

Description

0   This parameter is used to configure the Night Light on time.RR = Reserved HH = Hours MM = Minutes SS = Seconds Default = 0x00180000 means 6pm

Parameter Number

Parameter Size

Parameter Name

Description

20 2 kWh Report Threshold Energy kWh threshold reporting enable/disable. Unit kWh.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

100 0 10000 No No No

Value

 

Description

0   Disable kWh threshold reporting
1   kWh threshold setting.

Parameter Number

Parameter Size

Parameter Name

Description

21 2 Watt Report Threshold Threshold setting for Watt for inducing automatic report.Unit W.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2500 No No No

Value

 

Description

0   Disable Watt threshold reporting
1   Watt threshold setting.

Parameter Number

Parameter Size

Parameter Name

Description

22 1 Current Report Threshold Threshold settings for current for inducing automatic report. Unit A

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 150 No No No

Value

 

Description

0   Disable Watt threshold reporting
1   Current threshold setting.

Parameter Number

Parameter Size

Parameter Name

Description

23 2 Watt Automatic Report Time Set the automatic report time of Watt. Unit second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

600 0 65535 No No No

Value

 

Description

0   Set the automatic report time of Watt

Parameter Number

Parameter Size

Parameter Name

Description

24 2 kWh Automatic Report Time Set the automatic report time of kWh. Unit second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

600 0 65535 No No No

Value

 

Description

0   Set the automatic report time of kWh. Unit second.

Parameter Number

Parameter Size

Parameter Name

Description

25 2 Voltage Automatic Report Time Set the automatic report time of Voltage. Unit second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

600 0 65535 No No No

Value

 

Description

0   Set the automatic report time of Voltage. Unit second.

Parameter Number

Parameter Size

Parameter Name

Description

255 4 Factory Reset or Initialization Restore the product to factory settings and remove from the network. 0x55555555 - Restore the product to factory settings and remove from the network. Other - Initialize all configuration parameters to default values.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 4294967295 No No No

Value

 

Description

0   Initialize all configuration parameters to default values.
4294967295   Restore the product to factory settings and remove from the network

Parameter Number

Parameter Size

Parameter Name

Description

26 2 Current Automatic Report Time Set the automatic report time of Current. Unit second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

600 0 65535 No No No

Value

 

Description

0   Set the automatic report time of Current. Unit second.

Parameter Number

Parameter Size

Parameter Name

Description

3 4 Night Light Off Time This parameter is used to configure the Night Light off time. Only useful when parameter 1 is set to 1. RR = Reserved HH = Hours MM = Minutes SS = Seconds Default = 0x00060000 means 6am

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

393216 0 2316633 No No No

Value

 

Description

0   This parameter is used to configure the Night Light off time. Only useful when parameter 1 is set to 1. RR = Reserved HH = Hours MM = Minutes SS = Seconds Default = 0x00060000 means 6am

Parameter Number

Parameter Size

Parameter Name

Description

30 1 Alarm Settings Determines if alarms are enabled in Switch, and what Switch will react to which alarms.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

Parameter Number

Parameter Size

Parameter Name

Description

31 1 Alarm Response Enabled by Alarm Settings, and determines what the switch does in the case an alarm is triggered. 0 - disable , no reaction to alarm settings 1 - Switch is ON 2 - Switch is OFF 3~255 - Sets rate at which Switch turns ON and OFF in seconds. (i.e. If set to 3, then Switch will turn ON in 0.3 seconds, and then turn OFF in 0.3 seconds in a cycle until user disables the alarm manually. If set to 255, then it will cycle every 25.5 seconds)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

Value

 

Description

0   disable , no reaction to alarm settings
1   Switch is ON
2   Switch is OF
3   Sets rate at which Switch turns ON and OFF in seconds.

Parameter Number

Parameter Size

Parameter Name

Description

32 1 Alarm Disable Setting Determines the method of disabling the alarm of the device. 0 - Can be disabled by 1 tapping Switches action button once. 1 - Can be disabled by 2 tapping Switches action button within 1 second. 2 - Can be disabled by 4 tapping Switches action button within 2 seconds. 4 - Can be disabled by pressing and holding Switches action button about 4 seconds. 5~255 - Sets the duration of the alarm in seconds (i.e Sets this setting to 50, the alarm state of the switch will disable after 50 seconds)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 255 No No No

Value

 

Description

0   Can be disabled by 1 tapping Switches action button once.
1   Can be disabled by 2 tapping Switches action button within 1 second.
2   Can be disabled by 4 tapping Switches action button within 2 seconds.
4   Can be disabled by pressing and holding Switches action button about 4 seconds.
5   Sets the duration of the alarm in seconds (i.e Sets this setting to 50, the alarm state of the switch will disable after 50 seconds)

Parameter Number

Parameter Size

Parameter Name

Description

4 1 LED Blink Duration Set the duration of blink, unit second. 0 - indicates that it is not blinking 1~255 - set the duration

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

Value

 

Description

0   Indicates that it is not blinking
1   Set the duration

Parameter Number

Parameter Size

Parameter Name

Description

40 4 Automatic Off Timer Acts as auto off after as soon as the switch turns ON, setting is set in seconds. 0 - no auto off with timer 1~86400 - seconds

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 86400 No No No

Value

 

Description

0   no auto off with timer
1   seconds

Parameter Number

Parameter Size

Parameter Name

Description

41 4 Automatic On Timer Acts as auto on after as soon as the switch turns OFF, setting is set in seconds. 0 - no auto on with timer 1~86400 - seconds

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 86400 No No No

Value

 

Description

0   no auto on with timer
1   Seconds

Parameter Number

Parameter Size

Parameter Name

Description

42 1 Report Command Setting Which report will be sent to lifeline group when the output state is changed. 0 - Send nothing 1 - Send Basic Report 2 - Send Switch Binary Report

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Bit (Value)

 

Description

0 (1)   Send nothing
1 (2)   Send Basic Report
2 (4)   Send Switch Binary Report

Parameter Number

Parameter Size

Parameter Name

Description

5 1 LED Blink Speed Set amount of blinks per second. i.e. If set to 5, it should blink 5 times per second.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 24 No No No

Value

 

Description

1   Set amount of blinks per second.

Parameter Number

Parameter Size

Parameter Name

Description

6 2 Send Alert When In Use Send alert when in use. A Scene Activation Set command will be sent when energy draw is above this setting value. 0 - disable 1~3000 - enable, unit W

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

100 0 3000 No No No

Value

 

Description

0   Disable
1   Enable

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Plug Always On Prevents the plug from being turned off via its button. 0 - the plug will operate as normal and can be turned on or off. 1 - the button on the plug will be disabled for on and off commands, but still work for network inclusion and exclusion. 2 - the plug will ignore any commands to turn it off and it will ignore any use of the button (but still work for network inclusion and exclusion)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   the plug will operate as normal and can be turned on or off.
1 (2)   the button on the plug will be disabled for on and off commands, but still work for network inclusion and exclusion.
2 (4)   the plug will ignore any commands to turn it off and it will ignore any use of the button (but still work for network inclusion and exclusion)

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Power Out Action Set the plug’s action in case of power out. 0 - last status 1 - power on 2 - power off

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   Last status
1   Power On
2   Power Off

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Group3 Scene Id Set the scene id when Scene Activation Set Command sent through group3. Refer parameter 6 for more information.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 1 255 No No No

Value

 

Description

1   Set the scene id when Scene Activation Set Command sent through group3.