TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | LowBatPrecent | Low battery power level of alarm threshold values: the value range are 5~50 for percentage, the battery low power level can setting 5%~50%. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 5 | 50 | No | No | No |
Value |
Description |
||||
5 | 5: This value 5 here means that device will report a low batter alarm to association group 1 when the batter level is less than 5%. the value 50 means 5: This value 5 here means that device will report a low batter alarm to association group 1 when the batter level is more than 50%. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Pironoff | Enable/Disable the PIR 0 = Disable the PIR. 1 = Enable the PIR. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | the value 0 means to disable the PIR. the value 1 means to enable the PIR. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 2 | PirTimeout | Setup the wait time of PIR for clear the motion. Valid values: 0x05~0x3BC4 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 5 | 15300 | No | No | No |
Value |
Description |
||||
5 | The 0x05~0x3BC4 is a valid value range which could be used to set the PIR latency time to clear the previous data. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 1 | BasicEnable | When the Motion Sensor is triggered, if this parameter is 0x01 then it will send Basic set command to group 1. 0 = Don't send. 1 = Send. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | value 0 means that motion sensor won't send basic set to group 1 when the PIR is triggered, while 1 means yes. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | BasicReverse | PIR triggers the correspondence between the value of the Basic set and the PIR state. -If this value is 0x00 : PIR triggers send the basic set with 0xFF, PIR alarm release send the basic set with 0x00. -If this value is 0x01 : PIR triggers send the basic set with 0x00, PIR alarm release send the basic set with 0xFF. Only value 0x00 and 0x01 is valid . | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | 0x00-PIR triggers send the basic set with 0xFF, PIR alarm release send the basic set with 0x00. 0x01-PIR triggers send the basic set with 0x00, PIR alarm release send the basic set with 0xFF. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | PirSensitivity | Motion detection sensitivity level is a value between 0 and 10. This value affects the amount of motion energy required to generate a motion event and also affects the detection range and angle. 0 = Lowest Motion Sensitivity 10 = Highest Motion Sensitivity | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
9 | 0 | 10 | No | No | No |
Value |
Description |
||||
0 | 0 = Lowest Motion Sensitivity 10 = Highest Motion Sensitivity | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 1 | PirPetImmunity | Enable/disable pet immunity mode. This feature is lens dependent and detection range may be reduced when Pet Immunity is enabled. 0 = Disable the pet immunity mode 1 = Enable the pet immunity mode | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | 0 = Disable the pet immunity mode 1 = Enable the pet immunity mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | LightSensorSendType | Configure lightsensor to upload data form 1=Upload lumens value. 2=Upload day or night(By notification). 3=Upload lumens and day/night . | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 3 | No | No | No |
Value |
Description |
||||
1 | 1=Upload lumens value. 3=Upload lumens and day/night . | ||||