TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Motion Sensor Pet Immunity Z-Wave 700 (7CA-SS-VE-C0)

Z-Wave Certification Number: ZC12-20050060


Parameter Number

Parameter Size

Parameter Name

Description

10 1 LowBatPrecent Low battery power level of alarm threshold values: the value range are 5~50 for percentage, the battery low power level can setting 5%~50%.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 5 50 No No No

Value

 

Description

5   5: This value 5 here means that device will report a low batter alarm to association group 1 when the batter level is less than 5%. the value 50 means 5: This value 5 here means that device will report a low batter alarm to association group 1 when the batter level is more than 50%.

Parameter Number

Parameter Size

Parameter Name

Description

12 1 Pironoff Enable/Disable the PIR 0 = Disable the PIR. 1 = Enable the PIR.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   the value 0 means to disable the PIR. the value 1 means to enable the PIR.

Parameter Number

Parameter Size

Parameter Name

Description

13 2 PirTimeout Setup the wait time of PIR for clear the motion. Valid values: 0x05~0x3BC4

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

60 5 15300 No No No

Value

 

Description

5   The 0x05~0x3BC4 is a valid value range which could be used to set the PIR latency time to clear the previous data.

Parameter Number

Parameter Size

Parameter Name

Description

14 1 BasicEnable When the Motion Sensor is triggered, if this parameter is 0x01 then it will send Basic set command to group 1. 0 = Don't send. 1 = Send.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   value 0 means that motion sensor won't send basic set to group 1 when the PIR is triggered, while 1 means yes.

Parameter Number

Parameter Size

Parameter Name

Description

15 1 BasicReverse PIR triggers the correspondence between the value of the Basic set and the PIR state. -If this value is 0x00 : PIR triggers send the basic set with 0xFF, PIR alarm release send the basic set with 0x00. -If this value is 0x01 : PIR triggers send the basic set with 0x00, PIR alarm release send the basic set with 0xFF. Only value 0x00 and 0x01 is valid .

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   0x00-PIR triggers send the basic set with 0xFF, PIR alarm release send the basic set with 0x00. 0x01-PIR triggers send the basic set with 0x00, PIR alarm release send the basic set with 0xFF.

Parameter Number

Parameter Size

Parameter Name

Description

16 1 PirSensitivity Motion detection sensitivity level is a value between 0 and 10. This value affects the amount of motion energy required to generate a motion event and also affects the detection range and angle. 0 = Lowest Motion Sensitivity 10 = Highest Motion Sensitivity

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

9 0 10 No No No

Value

 

Description

0   0 = Lowest Motion Sensitivity 10 = Highest Motion Sensitivity

Parameter Number

Parameter Size

Parameter Name

Description

17 1 PirPetImmunity Enable/disable pet immunity mode. This feature is lens dependent and detection range may be reduced when Pet Immunity is enabled. 0 = Disable the pet immunity mode 1 = Enable the pet immunity mode

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   0 = Disable the pet immunity mode 1 = Enable the pet immunity mode

Parameter Number

Parameter Size

Parameter Name

Description

18 1 LightSensorSendType Configure lightsensor to upload data form 1=Upload lumens value. 2=Upload day or night(By notification). 3=Upload lumens and day/night .

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 3 No No No

Value

 

Description

1   1=Upload lumens value. 3=Upload lumens and day/night .