TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Threshold value battery alarm | The threshold of Low power. Percentage value from when the low battery alarm should be transmitted. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 5 | 50 | No | Yes | No |
Value |
Description |
||||
5 | Adjustable from 5 - 50 in percent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Proximity sensor Active / Deactive | Activates / deactivates the proximity sensor | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | Yes | No |
Value |
Description |
||||
0 | Sensor is deactivated | ||||
1 | Sensor is activated | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Waiting time between two motion alarms | The time to clear the motion. i.e. Waiting time from one motion alarm to the next triggering. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 2 | 30 | No | Yes | No |
Value |
Description |
||||
2 | Adjustable from 2 - 30 in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Proximity sensor Sensitivity | Sensitivity value of the proximity sensor. The value 31 is the lowest sensitivity. The value 4 is the highest sensitivity. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
9 | 4 | 31 | No | Yes | No |
Value |
Description |
||||
4 | Adjustable from 4 - 31 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Light sensor Active / Deactive | Activate/deactivate the light sensor. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | Yes | No |
Value |
Description |
||||
0 | Sensor is deactivated | ||||
1 | Sensor is activated | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Threshold value for day / night | Threshold value from which LUX value the day or night value is sent. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 0 | 255 | No | Yes | No |
Value |
Description |
||||
0 | Adjustable from 0 - 255 in Lux | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Key Tones Active / Deactive | Activates / deactivates the button tones. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | Yes | No |
Value |
Description |
||||
0 | Sound is deactivated | ||||
1 | Sound is activated | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Status display Active / Deactive | Enable / disable the status display when the device wakes up. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | Yes | No |
Value |
Description |
||||
0 | Display status is deactivated | ||||
1 | Display status is activated | ||||