Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Keypad (PLBE10000)

Z-Wave Certification Number: ZC12-20050055


Parameter Number

Parameter Size

Parameter Name

Description

2 1 Threshold value battery alarm The threshold of Low power. Percentage value from when the low battery alarm should be transmitted.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 5 50 No Yes No

Value

 

Description

5   Adjustable from 5 - 50 in percent

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Proximity sensor Active / Deactive Activates / deactivates the proximity sensor

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No Yes No

Value

 

Description

0   Sensor is deactivated
1   Sensor is activated

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Waiting time between two motion alarms The time to clear the motion. i.e. Waiting time from one motion alarm to the next triggering.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 2 30 No Yes No

Value

 

Description

2   Adjustable from 2 - 30 in seconds

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Proximity sensor Sensitivity Sensitivity value of the proximity sensor. The value 31 is the lowest sensitivity. The value 4 is the highest sensitivity.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

9 4 31 No Yes No

Value

 

Description

4   Adjustable from 4 - 31

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Light sensor Active / Deactive Activate/deactivate the light sensor.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No Yes No

Value

 

Description

0   Sensor is deactivated
1   Sensor is activated

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Threshold value for day / night Threshold value from which LUX value the day or night value is sent.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 0 255 No Yes No

Value

 

Description

0   Adjustable from 0 - 255 in Lux

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Key Tones Active / Deactive Activates / deactivates the button tones.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No Yes No

Value

 

Description

0   Sound is deactivated
1   Sound is activated

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Status display Active / Deactive Enable / disable the status display when the device wakes up.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No Yes No

Value

 

Description

0   Display status is deactivated
1   Display status is activated