Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Sensor Operation Mode | This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Internal Magnet Sensor Used and scene activation enabled | ||||
1 (2) | External Terminal Inputs Used and scene activation disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 2 | Time Delay of "On" command frame | On command is sent after a delay defined in this parameter. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | No |
Value |
Description |
||||
0 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 2 | Time Delay of "Off" command frame | Off command is sent after a delay defined in this parameter. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | No |
Value |
Description |
||||
0 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 2 | Delay of Tamper Alarm Cancellation | Time a tamper alarm is delayed. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | No |
Value |
Description |
||||
0 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Reporting Tamper Alarm Cancellation | This parameter defines if the alarm cancellation event is reported. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Do not send Report | ||||
1 (2) | Send Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 1 | Central Scene Event Functionality | This parameter enables/disables the central scene function. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disabled | ||||
1 (2) | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | Tilt Sensor Functionality | This parameter enables/disables the tilt function. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disabled | ||||
1 (2) | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | Tilt Sensor State | This parameter allows to set in what state is door/window when the tilt is in an OFF state. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | OFF when sensor is vertical | ||||
1 (2) | ON when sensor is vertical | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 1 | 5th Association Group triggers | Parameter defines events which result in sending On/Off commands to devices added to the 2nd Association Group. These commands are sent alternately to switch the devices On and Off. Commands represent the values of BASIC SET command frames. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Switch after Open and Close | ||||
1 | Switch after Open | ||||
2 | Switch after Close | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | Commands sent to 5th Association Group | Command frames sent to devices added to the 5th association group. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | On | ||||
1 | Off | ||||
2 | On and Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 1 | Value of ON command frame sent to 5th Associatio | The value of 0 turns OFF the device, 255 turns it On. In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level. 0-99 or 255 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Value | ||||
255 | Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Dry Contact Operation Mode | Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry contact terminals. 0 - NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN. 1 - NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN. 2 - NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal. 3 - NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN. | ||||
1 | NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN. | ||||
2 | NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal. | ||||
3 | NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
21 | 1 | Tilt sensitivity | You can use this parameter to adjust the tilt sensitivity if the tilt is too low or too high. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 1 | 100 | No | No | No |
Value |
Description |
||||
1 | Tilt Sensitivity | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
255 | 4 | Reset Parameter | 0 – Nothing happens 0x55555555 – Completely factory reset sensor and send device reset locally notification. All other values – Reset all Parameter settings to their default settings. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1431655765 | No | No | No |
Value |
Description |
||||
1 | Reset all Parameter settings to their default settings. | ||||
1431655765 | Completely factory reset sensor and send device reset locally notification. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Sensor State Polarity | This parameter defines the polarity of the magnet sensor. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Closed when Magnet near | ||||
1 (2) | Opened when Magnet near | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Visual LED Indications | This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
7 | 0 | 7 | No | No | No |
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Range Test after double click | Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disabled | ||||
1 (2) | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | 2nd Association Group Trigger | This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Switch after Open and Close | ||||
1 (2) | Switch after Open | ||||
2 (4) | Switch after Close | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Command Sent to Devices of Association Group 2 | This parameter defines which commands is sent to 2nd Association Group | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | On | ||||
1 (2) | Off | ||||
2 (4) | On and Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | BASIC command "On event" value | This is the BASIC command value sent in case of "On" event. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Value | ||||
255 | Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | BASIC command "Off event" value | This is the BASIC command value sent in case of "Off" event. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Value | ||||
255 | Value | ||||