Z-Wave Products

There are over 4376 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Door / Window Sensor 7 Pro (ZWA012-C)

Z-Wave Certification Number: ZC12-20060075


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Sensor Operation Mode This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Internal Magnet Sensor Used and scene activation enabled
1 (2)   External Terminal Inputs Used and scene activation disabled

Parameter Number

Parameter Size

Parameter Name

Description

10 2 Time Delay of "On" command frame On command is sent after a delay defined in this parameter.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 32400 No No No

Value

 

Description

0   seconds

Parameter Number

Parameter Size

Parameter Name

Description

11 2 Time Delay of "Off" command frame Off command is sent after a delay defined in this parameter.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 32400 No No No

Value

 

Description

0   seconds

Parameter Number

Parameter Size

Parameter Name

Description

12 2 Delay of Tamper Alarm Cancellation Time a tamper alarm is delayed.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 32400 No No No

Value

 

Description

0   seconds

Parameter Number

Parameter Size

Parameter Name

Description

13 1 Reporting Tamper Alarm Cancellation This parameter defines if the alarm cancellation event is reported.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Do not send Report
1 (2)   Send Report

Parameter Number

Parameter Size

Parameter Name

Description

14 1 Central Scene Event Functionality This parameter enables/disables the central scene function.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Disabled
1 (2)   Enabled

Parameter Number

Parameter Size

Parameter Name

Description

15 1 Tilt Sensor Functionality This parameter enables/disables the tilt function.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Disabled
1 (2)   Enabled

Parameter Number

Parameter Size

Parameter Name

Description

16 1 Tilt Sensor State This parameter allows to set in what state is door/window when the tilt is in an OFF state.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   OFF when sensor is vertical
1 (2)   ON when sensor is vertical

Parameter Number

Parameter Size

Parameter Name

Description

17 1 5th Association Group triggers Parameter defines events which result in sending On/Off commands to devices added to the 2nd Association Group. These commands are sent alternately to switch the devices On and Off. Commands represent the values of BASIC SET command frames.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   Switch after Open and Close
1   Switch after Open
2   Switch after Close

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Commands sent to 5th Association Group Command frames sent to devices added to the 5th association group.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   On
1   Off
2   On and Off

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Value of ON command frame sent to 5th Associatio The value of 0 turns OFF the device, 255 turns it On. In case of associating the Dimmer or Roller Shutter module, values 1-99 allow to set an Associated device to a specified level. 0-99 or 255

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

Value

 

Description

0   Value
255   Value

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Dry Contact Operation Mode Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry contact terminals. 0 - NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN. 1 - NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN. 2 - NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal. 3 - NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN.
1   NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN.
2   NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal.
3   NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal.

Parameter Number

Parameter Size

Parameter Name

Description

21 1 Tilt sensitivity You can use this parameter to adjust the tilt sensitivity if the tilt is too low or too high.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 1 100 No No No

Value

 

Description

1   Tilt Sensitivity

Parameter Number

Parameter Size

Parameter Name

Description

255 4 Reset Parameter 0 – Nothing happens 0x55555555 – Completely factory reset sensor and send device reset locally notification. All other values – Reset all Parameter settings to their default settings.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1431655765 No No No

Value

 

Description

1   Reset all Parameter settings to their default settings.
1431655765   Completely factory reset sensor and send device reset locally notification.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Sensor State Polarity This parameter defines the polarity of the magnet sensor.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Closed when Magnet near
1 (2)   Opened when Magnet near

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Visual LED Indications This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

7 0 7 No No No

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Range Test after double click Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Disabled
1 (2)   Enabled

Parameter Number

Parameter Size

Parameter Name

Description

6 1 2nd Association Group Trigger This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   Switch after Open and Close
1 (2)   Switch after Open
2 (4)   Switch after Close

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Command Sent to Devices of Association Group 2 This parameter defines which commands is sent to 2nd Association Group

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Bit (Value)

 

Description

0 (1)   On
1 (2)   Off
2 (4)   On and Off

Parameter Number

Parameter Size

Parameter Name

Description

8 1 BASIC command "On event" value This is the BASIC command value sent in case of "On" event.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

Value

 

Description

0   Value
255   Value

Parameter Number

Parameter Size

Parameter Name

Description

9 1 BASIC command "Off event" value This is the BASIC command value sent in case of "Off" event.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

Value

 

Description

0   Value
255   Value