There are over 4290 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Motion Detector (Motion Detector v2)

Z-Wave Certification Number: ZC12-20050057


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Heartbeat Interval This parameter is the number minutes between heartbeats. Heartbeats are automatic battery reports on a timer after the last event.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

70 1 70 No No Yes

Value

 

Description

1   This parameter indicates the time between heartbeats in minutes.

Parameter Number

Parameter Size

Parameter Name

Description

10 1 Lighting Delay Delay used to turn off lights when motion is no longer detected

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 60 No No Yes

Value

 

Description

0   This parameter indicates the Delay used to turn off lights when motion is no longer detected.

Parameter Number

Parameter Size

Parameter Name

Description

11 2 Supervisory Report Timeout The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10000 500 30000 No No Yes

Value

 

Description

500   This parameter indicates the number of milliseconds waiting for a Supervisory Report.

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Application Retriess Number of application level retries attempted for messages either not ACKed or messages encapsulated via supervision get that did not receive a report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 5 No No Yes

Value

 

Description

0   This parameter indicates the Number of application level retries.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Application Level Retry Base Wait Time Period The number base seconds used in the calculation for sleeping between retry messages.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 96 No No Yes

Value

 

Description

1   This parameter indicates the number base seconds used in the calculation for sleeping between retry messages.

Parameter Number

Parameter Size

Parameter Name

Description

4 1 LED Indicator Enable This parameter allows a user, via software, to configure the various LED indications on the device. 0 == Don't show green 1 == Show green after Supervision Report Intrusion (Fault) 2 == Show green after Supervision Report both Intrusion and Intrusion clear

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No Yes

Value

 

Description

0   This parameter allows a user to configure LED indications on the device.

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Runtime Occ Clear Delay Delay time in seconds for occupancy signal to clear

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No Yes

Value

 

Description

0   Delay time in seconds for occupancy signal to clear

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Runtime Intrusion Clear Delay Delay time in seconds for intrusion signal to clear

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No Yes

Value

 

Description

0   Delay time in seconds for intrusion signal to clear

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Runtime Std Clear Delay Standard delay time in seconds

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No Yes

Value

 

Description

0   This parameter is the Standard delay time in seconds

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Motion Detection Mode Adjusts motion sensitivity

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 4 No No Yes

Value

 

Description

0   This parameter adjusts motion sensitivity

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Lighting Enabled Enable or Disable light sensor

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No Yes

Value

 

Description

0   This parameter is used to Enable or Disable light sensor