There are over 4290 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Heartbeat Interval | This parameter is the number minutes between heartbeats. Heartbeats are automatic battery reports on a timer after the last event. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
70 | 1 | 70 | No | No | Yes |
Value |
Description |
||||
1 | This parameter indicates the time between heartbeats in minutes. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Lighting Delay | Delay used to turn off lights when motion is no longer detected | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 60 | No | No | Yes |
Value |
Description |
||||
0 | This parameter indicates the Delay used to turn off lights when motion is no longer detected. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 2 | Supervisory Report Timeout | The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10000 | 500 | 30000 | No | No | Yes |
Value |
Description |
||||
500 | This parameter indicates the number of milliseconds waiting for a Supervisory Report. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Application Retriess | Number of application level retries attempted for messages either not ACKed or messages encapsulated via supervision get that did not receive a report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 5 | No | No | Yes |
Value |
Description |
||||
0 | This parameter indicates the Number of application level retries. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Application Level Retry Base Wait Time Period | The number base seconds used in the calculation for sleeping between retry messages. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 96 | No | No | Yes |
Value |
Description |
||||
1 | This parameter indicates the number base seconds used in the calculation for sleeping between retry messages. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | LED Indicator Enable | This parameter allows a user, via software, to configure the various LED indications on the device. 0 == Don't show green 1 == Show green after Supervision Report Intrusion (Fault) 2 == Show green after Supervision Report both Intrusion and Intrusion clear | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | Yes |
Value |
Description |
||||
0 | This parameter allows a user to configure LED indications on the device. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Runtime Occ Clear Delay | Delay time in seconds for occupancy signal to clear | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | Delay time in seconds for occupancy signal to clear | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Runtime Intrusion Clear Delay | Delay time in seconds for intrusion signal to clear | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | Delay time in seconds for intrusion signal to clear | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Runtime Std Clear Delay | Standard delay time in seconds | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | Yes |
Value |
Description |
||||
0 | This parameter is the Standard delay time in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Motion Detection Mode | Adjusts motion sensitivity | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 0 | 4 | No | No | Yes |
Value |
Description |
||||
0 | This parameter adjusts motion sensitivity | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Lighting Enabled | Enable or Disable light sensor | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | Yes |
Value |
Description |
||||
0 | This parameter is used to Enable or Disable light sensor | ||||