Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Ring Keypad v2 (Keypad v2)

Z-Wave Certification Number: ZC12-20050056


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Heartbeat Interval This parameter is the number minutes between heartbeats. Heartbeats are automatic battery reports on a timer after the last event.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

70 1 70 No No Yes

Value

 

Description

1   This parameter is the interval between heartbeats in minutes.

Parameter Number

Parameter Size

Parameter Name

Description

10 1 Button Press Display Timeout Timeout in seconds when any button is pressed, but a sequence is not completed and buttons are no longer being pressed

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 30 No No Yes

Value

 

Description

0   This parameter is the Timeout in seconds when any button is pressed.

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Status Change Display Timeout Timeout in seconds when indicator command is received from the hub to change status

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 30 No No Yes

Value

 

Description

1   This parameter is the Timeout in seconds when indicator command is received from the hub to change status

Parameter Number

Parameter Size

Parameter Name

Description

12 1 Security Mode Brightness Adjusts the brightness of the security mode buttons

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

100 0 100 No No Yes

Value

 

Description

0   This parameter adjusts the brightness of the security mode buttons

Parameter Number

Parameter Size

Parameter Name

Description

13 1 Key Backlight Brightness Adjusts the brightness of the keypad backlight. Used for Key Backlight LEDs only

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

100 0 100 No No Yes

Value

 

Description

0   This parameter adjusts the brightness of the keypad backlight. Used for Key Backlight LEDs only

Parameter Number

Parameter Size

Parameter Name

Description

14 1 Ambient Light Sensor Level Light threshold where keypad will stop backlighting if higher than

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 0 100 No No Yes

Value

 

Description

0   This parameter is the light threshold where keypad will stop backlighting if higher than

Parameter Number

Parameter Size

Parameter Name

Description

15 1 Proximity On/OFF Turn On and Off the Proximity Detection.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No Yes

Value

 

Description

0   This parameter is the Turn On and Off the Proximity Detection.

Parameter Number

Parameter Size

Parameter Name

Description

16 1 Ramp Time Config Ramp time in units of ten milliseconds each to turn the LEDs on/off. Applies to all LEDs on the keypad

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 0 255 No No Yes

Value

 

Description

0   This parameter is the ramp time to turn the LEDs on/off in milliseconds.

Parameter Number

Parameter Size

Parameter Name

Description

17 1 Low Battery Threshold The percentage level at which the display would turn on the yellow battery indicator (whenever the display is on).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

30 0 100 No No Yes

Value

 

Description

0   This parameter is the percentage level at which the display would turn on.

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Languages Set Sets the language on the keypad

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 31 No No Yes

Value

 

Description

0   This parameter sets the language on the keypad

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Warn Battery Threshold The percentage level at which the display would turn on the red battery indicator (whenever the display is on).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 0 100 No No Yes

Value

 

Description

0   This parameter is the percentage level at which the display would turn on the red battery indicator.

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Application Retries Number of application level retries attempted for messages either not ACKed or messages encapsulated via supervision get that did not receive a report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 5 No No Yes

Value

 

Description

0   This parameter is the number of application level retries attempted for messages

Parameter Number

Parameter Size

Parameter Name

Description

20 1 System Security Mode Blink Duration Configurable ON time for the blink for config #22 which allows us to modify the time for the LED to be active when set to blink on a period per config 22.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 1 60 No No Yes

Value

 

Description

1   This parameter is the Configurable ON time for the blink.

Parameter Number

Parameter Size

Parameter Name

Description

21 2 Supervision Report Timeout The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10000 500 30000 No No Yes

Value

 

Description

500   This parameter is the number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry.

Parameter Number

Parameter Size

Parameter Name

Description

22 2 System Security Mode Display System Security Mode Display: (Always, Sometimes, Never). 601 = Always On 1 - 600 = periodic interval 0 = Always Off, except when there's activit

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 601 No No Yes

Value

 

Description

0   This parameter is the System Security Mode Display options.

Parameter Number

Parameter Size

Parameter Name

Description

23 4 Languages Supported Returns bitmask of languages supported. Bits set to 1 indicate that the language is supported

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

37 0 4294967295 Yes No Yes

Parameter Number

Parameter Size

Parameter Name

Description

24 1 Calibrate Speaker When set to 1, calibrates the speaker

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No Yes

Value

 

Description

0   This parameter is the Speaker calibration value.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Application Level Retry Base Wait Time Period The number base seconds used in the calculation for sleeping between retry messages.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 60 No No Yes

Value

 

Description

1   This parameter is the Base seconds used in the calculation for sleeping between retry messages.

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Announcement Audio Volume Announce audio volume adjustment

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

7 0 10 No No Yes

Value

 

Description

0   This parameter is the Announce audio volume adjustment

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Key Tone Volume Key Tone Volume adjustment

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 0 10 No No Yes

Value

 

Description

0   This parameter is the Key Tone Volume adjustment

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Siren Volume Siren Volume adjustment

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 0 10 No No Yes

Value

 

Description

0   This parameter is the Siren Volume adjustment

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Long press emergency duration (seconds) This parameter allows a user to configure the duration in seconds for the hold time required to capture a long press . This includes Emergency Buttons + Mode Buttons (Police, Fire, Medical, Disarmed, Home, Away)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 2 5 No No Yes

Value

 

Description

2   This parameter is the special key long press duration - hold time required to capture a long press in seconds.

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Long press number pad duration (seconds) This parameter allows a user to configure the duration in seconds for the hold time required to capture a long press . This includes Number Pad + Check & X (0-9, Check, X)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 2 5 No No Yes

Value

 

Description

2   This parameter is the hold time required to capture a long press in seconds.

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Proximity Display Timeout Timeout in seconds when proximity is detected and no input is received

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 30 No No Yes

Value

 

Description

0   This parameter is the Timeout in seconds when proximity is detected and no input is received