There are over 4400 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 2 | Time Delay of "Off" command frame | Off command is sent after a delay defined in this parameter. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | No |
Value |
Description |
||||
0 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 2 | Delay of Tamper Alarm Cancellation | Time a tamper alarm is delayed. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | No |
Value |
Description |
||||
0 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Reporting Tamper Alarm Cancellation | This parameter defines if the alarm cancellation event is reported. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Do not send Report | ||||
1 (2) | Send Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | Minimum Temperature change to report | This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 18, may still be active. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Disabled | ||||
1 | 1/10 degree | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 1 | Minimum humidity change to report | This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 18, may still be active. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 20 | No | No | No |
Value |
Description |
||||
0 | Disabled | ||||
1 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 2 | Temperature and Humidity Periodic Reports | This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 16 and 17, may still be active. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
43200 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | Disabled | ||||
900 | Seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
255 | 4 | Reset Parameter | This parameter helps reset configuration parameters and the device to factory defaults 1 - 1431655764 (0x55555554) - Reset all Parameter settings to their default settings. 1431655765 - Completely factory reset sensor and send device reset locally notification. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1431655765 | No | No | No |
Value |
Description |
||||
1 | Reset all Parameter settings to their default settings. | ||||
1431655765 | Completely factory reset sensor and send device reset locally notification. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Visual LED Indications | This parameter defines when LEDs will indicate events. Disabling all indications may extend battery life. Value 0 means - No Indications. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
7 | 0 | 7 | No | No | No |
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Range Test after double click | Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disabled | ||||
1 (2) | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | 2nd Association Group Trigger | This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Switch after Water Leakage Start and Stop | ||||
1 (2) | Switch after Water Leakage Start and Stop | ||||
2 (4) | Switch after Water Leakage Start and Stop | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Command Sent to Devices of Association Group 2 | This parameter defines which commands is sent to 2nd Association Group | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | On | ||||
1 (2) | Off | ||||
2 (4) | On and Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | BASIC command "On event" value | This is the BASIC command value sent in case of "On" event. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Value | ||||
255 | Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | BASIC command "Off event" value | This is the BASIC command value sent in case of "Off" event. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Value | ||||
255 | Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 2 | Time Delay of "On" command frame | On command is sent after a delay defined in this parameter. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 32400 | No | No | No |
Value |
Description |
||||
0 | seconds | ||||