There are over 4290 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | IN1 Mode | -128 to 127 (Default) |
Values From -128~127 will tell the device to active IN1 Mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | IN2 Low-threshold Voltage Trigger Level | -128 to 127 (Default) |
Low threshold voltage level for trigger on (or trigger off, depending on mode). | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | IN3 Mode | -128 to 127 (Default) |
Values From -128~127 will tell the device to active IN3 Mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | OUT3 relay Trigger ON time | -128 to 127 (Default) |
Relay 3 turn on period | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Group 4 turn on time when triggered by IN3 | -128 to 127 (Default) |
Group 4 turn on period. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | IN3 Hi-threshold Voltage Trigger Level | -128 to 127 (Default) |
High threshold voltage level for trigger on (or trigger off, depending on mode). | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | IN3 Low-threshold Voltage Trigger Level | -128 to 127 (Default) |
Low threshold voltage level for trigger on (or trigger off, depending on mode). | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Auto Report Voltage time | -128 to 127 (Default) |
Periodic auto report for voltage input at IN1~3. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Tamper Mode | 0 to 7 (Default) |
0: No activate relay out; 1: Activate OUT1 Relay when Tamper; 2: Activate OUT2 Relay when Tamper; 3: Activate OUT1 & OUT2 Relay when Tamper; 4: Activate OUT3 Relay when Tamper; 5: Activate OUT1 & OUT3 Relay when Tamper; 6: Activate OUT2 & OUT3 Relay when Tamper; 7: Activate OUT1 & OUT2 & OUT3 Relay when Tamper | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Set ARM/DISARM Input | 0 to 3 (Default) |
0: No ARM/DISARM Input 1: IN 1 is ARM/DISARM Input 2: IN 2 is ARM/DISARM Input 3: IN 3 is ARM/DISARM Input | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | OUT1 relay Trigger ON time | -128 to 127 (Default) |
Relay 1 turn on period | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Group 2 turn on time when triggered by IN1 | -128 to 127 (Default) |
Group 2 turn on period. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | IN1 Hi-threshold Voltage Trigger Level | -128 to 127 (Default) |
High threshold voltage level for trigger on (or trigger off, depending on mode). | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | IN1 Low-threshold Voltage Trigger Level | -128 to 127 (Default) |
Low threshold voltage level for trigger on (or trigger off, depending on mode). | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | IN2 Mode | -128 to 127 (Default) |
Values From -128~127 will tell the device to active IN2 Mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | OUT2 relay Trigger ON time | -128 to 127 (Default) |
Relay 2 turn on period | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Group 3 turn on time when triggered by IN2 | -128 to 127 (Default) |
Group 3 turn on period. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | IN2 Hi-threshold Voltage Trigger Level | -128 to 127 (Default) |
High threshold voltage level for trigger on (or trigger off, depending on mode). | |