Z-Wave Products

There are over 4347 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: AërQ - Temperature & Humidity Sensor (ZWA009-C)

Z-Wave Certification Number: ZC12-20080086


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Minimum Temperature change to report This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 0 100 No No No

Value

 

Description

0   disabled
1   1/10 degree

Parameter Number

Parameter Size

Parameter Name

Description

10 1 High Temperature Trigger BASIC Set Command Value This defines what BASIC command shall be sent out into association group 2

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

Value

 

Description

0   Value

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Low Humidity Trigger BASIC Set Command Value This defines what BASIC command shall be sent out into association group 5

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

Value

 

Description

0   Value

Parameter Number

Parameter Size

Parameter Name

Description

12 1 High Humidity Trigger BASIC Set Command Value This defines what BASIC command shall be sent out into association group 4

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 255 No No No

Value

 

Description

0   Value

Parameter Number

Parameter Size

Parameter Name

Description

13 1 Offset value for Mould danger notification This value allows to increase the humidity threshold for mold danger notification by max 10%

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 10 No No No

Value

 

Description

0   %

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Minimum humidity change to report This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be active.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 20 No No No

Value

 

Description

0   disabled
1   %

Parameter Number

Parameter Size

Parameter Name

Description

255 4 Reset parameter This parameter helps reset configuration parameters and the device to factory defaults.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1431655765 No No No

Value

 

Description

1   Reset all Parameter settings to their default settings.
1431655765   Completely factory reset sensor and send device reset locally notification.

Parameter Number

Parameter Size

Parameter Name

Description

4 2 Temperature and Humidity Periodic Reports This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

43200 0 65535 No No No

Value

 

Description

0   disabled
900   seconds

Parameter Number

Parameter Size

Parameter Name

Description

5 2 Temperature Upper Watermark value This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1000 No No No

Value

 

Description

0   disabled
1   1/10 degree

Parameter Number

Parameter Size

Parameter Name

Description

6 2 Temperature Lower Watermark value This parameter defines a temperature. If the measured temperature drops below this watermark a BASIC command is sent into Association Group 3

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1000 No No No

From

 

To

Description

0   0 disabled
200   1000 1/10 degree

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Humidity Upper Watermark value This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 90 No No No

Value

 

Description

0   disabled
1   %

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Humidity Lower Watermark value This parameter defines a relative humidity. If the measured temperature drops below this relative humidity a BASIC command is sent into Association Group 5

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 90 No No No

Value

 

Description

0   disabled
1   %

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Low Temperature Trigger BASIC Set Command Value This defines what BASIC command shall be sent out into association group 3

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

255 0 255 No No No

Value

 

Description

0   Values