There are over 3000 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z-Wave standard. Browse our Product Finder to see what Z-Wave can do for you.

Z-Wave Configuration Capabilities

Model: WALLI CONTROLLER (FGWCEU-201)

Z-Wave Certification Number: ZC12-20060078


Parameter Number

Parameter Size

Parameter Name

Description

13 1 LED frame – brightness This parameter allows to adjust the LED frame brightness.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

100 0 100 No No Yes

Value

 

Description

0   LED disabled
1   1-100% brightness

Parameter Number

Parameter Size

Parameter Name

Description

150 2 LED ring – first button This parameter defines the colour of first button indicator (upper part of the LED ring) for indications using Indicator CC.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 8 No No Yes

Value

 

Description

0   LED disabled
1   White
2   Red
3   Green
4   Blue
5   Yellow
6   Cyan
7   Magenta
8   LAPD (blinking red-white-blue)

Parameter Number

Parameter Size

Parameter Name

Description

151 2 LED ring – second button This parameter defines the colour of second button indicator (lower part of the LED ring) for indications using Indicator CC.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 8 No No Yes

Value

 

Description

1   White
2   Red
3   Green
4   Blue
5   Yellow
6   Cyan
7   Magenta
8   LAPD (blinking red-white-blue)
0   LED disabled

Parameter Number

Parameter Size

Parameter Name

Description

152 2 1st button - double click value This parameter defines value of Basic Set or Multilevel Set frame (depending on selected mode) sent to associated devices after double click. This parameter is not relevant for Scene Controller Mode.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 0 255 No No No

Value

 

Description

0   value of Basic Set
255   Multilevel Set frame

Parameter Number

Parameter Size

Parameter Name

Description

153 2 2nd button - double click value This parameter defines value of Basic Set or Multilevel Set frame (depending on selected mode) sent to associated devices after double click. This parameter is not relevant for Scene Controller Mode.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 0 255 No No Yes

Value

 

Description

0   value of Basic Set
255   Multilevel Set frame

Parameter Number

Parameter Size

Parameter Name

Description

20 1 Operation mode This parameter defines operation of the device. Choose the mode depending on the type of the device you want to control remotely

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 6 No No Yes

Value

 

Description

0   scene controller mode
1   double button mode
2   3-position single button mode
3   switch controller mode
4   dimmer controller mode
5   roller shutter / gate controller mode (step-by-step)
6   venetian blinds controller mode (step-by-step)