There are over 4220 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Universal module with 3 In 3 Out (SA301-1)

Z-Wave Certification Number: ZC10-20056913


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 IN1 Mode 0 to 255
(Default)
Size =1, Default Value = 0x40 Bit 7:Corresponds to values in Config 4, 5 - 0 = Trigger on when voltage under Low-threshold, Trigger off when over Hi-threshold - 1 = Trigger on when voltage over Hi-threshold, Trigger off when under Low-threshold Bit 6:IN1 3.3V pull-high On/Off , 0 = Off, 1 = On Bit 5-4 : Fixed at 0. Bit 3:1 = Activate OUT3 relay when IN1 trigger Bit 2:1 = Activate OUT2 relay when IN1 trigger Bit 1:1 = Activate OUT1 relay when IN1 trigger Bit 0:Fixed at 0.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 IN2 Low-threshold Voltage Trigger Level 0 to 255
(Default)
Size =1 Default Value = 0x0A (IN2 trigger on when under 1000mV)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 IN3 Mode 0 to 255
(Default)
Same as for IN1 Bit 7:Corresponds to values in Config 14, 15

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 OUT3 relay Trigger ON time 0 to 255
(Default)
Size =1, Default Value = 0x05 (500ms) Step of 100ms, ‘0’ = remain on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Group 4 turn on time when triggered by IN3 0 to 255
(Default)
Size =1, Default Value = 0xB4 (Off after 180 secs) Step of 1 sec, ‘0’ = remain on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 IN3 Hi-threshold Voltage Trigger Level 0 to 255
(Default)
Size =1, Default Value = 0x19 (IN3 trigger off when over 2500mV). Step of 100mV.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 IN3 Low-threshold Voltage Trigger Level 0 to 255
(Default)
Size =1 Default Value = 0x0A (IN3 trigger on when under 1000mV)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 1 Auto Report Voltage time 0 to 255
(Default)
Size =1, Default Value = 0x1E (30mins) Step= 1 min.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Tamper Mode 0 to 7
(Default)
Size =1, Default Value = 0x00 Bit 3:1 = Activate OUT3 Relay when Tamper Bit 2:1 = Activate OUT2 Relay when Tamper Bit 1:1 = Activate OUT1 Relay when Tamper

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Set ARM/DISARM Input 0 to 3
(Default)
0: No ARM/DISARM Input 1: IN 1 is ARM/DISARM Input 2: IN 2 is ARM/DISARM Input 3: IN 3 is ARM/DISARM Input

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 OUT1 relay Trigger ON time 0 to 255
(Default)
Size =1, Default Value = 0x05 (500ms) Step of 100ms, ‘0’ = remain on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Group 2 turn on time when triggered by IN1 0 to 255
(Default)
Size =1, Default Value = 0xB4 (Off after 180 secs) Step of 1 sec, ‘0’ = remain on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 IN1 Hi-threshold Voltage Trigger Level 0 to 255
(Default)
Size =1, Default Value = 0x19 (IN1 trigger off when over 2500mV). Step of 100mV.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 IN1 Low-threshold Voltage Trigger Level 0 to 255
(Default)
Size =1 Default Value = 0x0A (IN1 trigger on when under 1000mV)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 IN2 Mode 0 to 255
(Default)
Same as for IN1 Bit 7:Corresponds to values in Config 9, 10

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 OUT2 relay Trigger ON time 0 to 255
(Default)
Size =1, Default Value = 0x05 (500ms) Step of 100ms, ‘0’ = remain on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Group 3 turn on time when triggered by IN2 0 to 255
(Default)
Size =1, Default Value = 0xB4 (Off after 180 secs) Step of 1 sec, ‘0’ = remain on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 IN2 Hi-threshold Voltage Trigger Level 0 to 255
(Default)
Size =1, Default Value = 0x19 (IN2 trigger off when over 2500mV). Step of 100mV.