Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | IN1 Mode | 0 to 255 (Default) |
Size =1, Default Value = 0x40 Bit 7:Corresponds to values in Config 4, 5 - 0 = Trigger on when voltage under Low-threshold, Trigger off when over Hi-threshold - 1 = Trigger on when voltage over Hi-threshold, Trigger off when under Low-threshold Bit 6:IN1 3.3V pull-high On/Off , 0 = Off, 1 = On Bit 5-4 : Fixed at 0. Bit 3:1 = Activate OUT3 relay when IN1 trigger Bit 2:1 = Activate OUT2 relay when IN1 trigger Bit 1:1 = Activate OUT1 relay when IN1 trigger Bit 0:Fixed at 0. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | IN2 Low-threshold Voltage Trigger Level | 0 to 255 (Default) |
Size =1 Default Value = 0x0A (IN2 trigger on when under 1000mV) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | IN3 Mode | 0 to 255 (Default) |
Same as for IN1 Bit 7:Corresponds to values in Config 14, 15 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | OUT3 relay Trigger ON time | 0 to 255 (Default) |
Size =1, Default Value = 0x05 (500ms) Step of 100ms, ‘0’ = remain on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Group 4 turn on time when triggered by IN3 | 0 to 255 (Default) |
Size =1, Default Value = 0xB4 (Off after 180 secs) Step of 1 sec, ‘0’ = remain on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | IN3 Hi-threshold Voltage Trigger Level | 0 to 255 (Default) |
Size =1, Default Value = 0x19 (IN3 trigger off when over 2500mV). Step of 100mV. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | IN3 Low-threshold Voltage Trigger Level | 0 to 255 (Default) |
Size =1 Default Value = 0x0A (IN3 trigger on when under 1000mV) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Auto Report Voltage time | 0 to 255 (Default) |
Size =1, Default Value = 0x1E (30mins) Step= 1 min. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Tamper Mode | 0 to 7 (Default) |
Size =1, Default Value = 0x00 Bit 3:1 = Activate OUT3 Relay when Tamper Bit 2:1 = Activate OUT2 Relay when Tamper Bit 1:1 = Activate OUT1 Relay when Tamper | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Set ARM/DISARM Input | 0 to 3 (Default) |
0: No ARM/DISARM Input 1: IN 1 is ARM/DISARM Input 2: IN 2 is ARM/DISARM Input 3: IN 3 is ARM/DISARM Input | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | OUT1 relay Trigger ON time | 0 to 255 (Default) |
Size =1, Default Value = 0x05 (500ms) Step of 100ms, ‘0’ = remain on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Group 2 turn on time when triggered by IN1 | 0 to 255 (Default) |
Size =1, Default Value = 0xB4 (Off after 180 secs) Step of 1 sec, ‘0’ = remain on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | IN1 Hi-threshold Voltage Trigger Level | 0 to 255 (Default) |
Size =1, Default Value = 0x19 (IN1 trigger off when over 2500mV). Step of 100mV. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | IN1 Low-threshold Voltage Trigger Level | 0 to 255 (Default) |
Size =1 Default Value = 0x0A (IN1 trigger on when under 1000mV) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | IN2 Mode | 0 to 255 (Default) |
Same as for IN1 Bit 7:Corresponds to values in Config 9, 10 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | OUT2 relay Trigger ON time | 0 to 255 (Default) |
Size =1, Default Value = 0x05 (500ms) Step of 100ms, ‘0’ = remain on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Group 3 turn on time when triggered by IN2 | 0 to 255 (Default) |
Size =1, Default Value = 0xB4 (Off after 180 secs) Step of 1 sec, ‘0’ = remain on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | IN2 Hi-threshold Voltage Trigger Level | 0 to 255 (Default) |
Size =1, Default Value = 0x19 (IN2 trigger off when over 2500mV). Step of 100mV. | |