There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | User Temperature Calibration | -450 to 450 (Default) |
step-size = 10, in steps of 0.1°F | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Temperature Limit - Cool Max | 60 to 95 (Default) |
Cool Max (F) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Temperature Limit - Cool Min | 50 to 75 (Default) |
Cool Min (F) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Temperature Minimum Setpoint Deadband | 200 to 500 (Default) |
step-size = 10 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Enable / Disable Emergency heat option in mode menu | 0 | disable | |
0 to 1 (Default) |
enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | Ambient Temperature Change Step-size | 50 (Default) |
0.5F (0.25C) | |
100 | 1.0F (0.50C) | ||||
150 | 1.5F (0.75C) | ||||
200 | 2.0F (1.00C) | ||||
250 | 2.5F (1.25C) | ||||
300 | 3.0F (1.50C) | ||||
350 | 3.5F (1.75C) | ||||
400 | 4.0F (2.00C) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Regular Ambient Temperature Reporting Interval | 1 to 24 (Default) |
1 - 24 hours | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Regular Operating State Reporting Interval | 1 to 24 (Default) |
1 - 24 hours | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Command Echo | 0 | disable | |
1 (Default) |
enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Temperature Unit (C/F) | 0 | C | |
1 (Default) |
F | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Available Control mode | 0 (Default) |
Heat and Cool, Auto | |
1 | Heat Only | ||||
2 | Cool Only | ||||
3 | Heat and Cool, no Auto | ||||
4 | reserved | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | System Type | 0 (Default) |
Furnace Gas | |
1 | Furnace Electric | ||||
2 | Heat Pump | ||||
3 | Boiler no fan | ||||
4 | reserved | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Reversal valve Type in Heat Pump | 0 (Default) |
O-valve | |
1 | B-valve | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Temperature Limit - Heat Max | 60 to 90 (Default) |
Heat Max (F) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Temperature Limit - Heat Min | 45 to 60 (Default) |
Heat Min (F) | |