There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Fan & Light Switch (LZW36)

Z-Wave Certification Number: ZC12-20060074


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Dimming Speed - Light This changes the speed in which the attached light dims up or down. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 100 No No No

Value

 

Description

0   Speed at which light dims up or down (increments)

Parameter Number

Parameter Size

Parameter Name

Description

10 2 Auto Off Timer – Light Automatically turns the light off after this many seconds. When the switch is turned on a timer is started that is the duration of this setting. When the timer expires, the switch is turned off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 32767 No No No

Value

 

Description

0   Disabled
1   Seconds

Parameter Number

Parameter Size

Parameter Name

Description

11 2 Auto Off Timer – Fan Automatically turns the fan off after this many seconds. When the fan is turned on a timer is started that is the duration of this setting. When the timer expires, the fan is turned off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 32767 No No No

Value

 

Description

0   Disabled
1   Seconds

Parameter Number

Parameter Size

Parameter Name

Description

12 1 Default Level (Local) – Light Default level for the dimmer when it is powered on from the local switch. A setting of 0 means that the switch will return to the level that it was on before it was turned off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 99 No No No

Value

 

Description

0   Sets back to light level prior to switch turning off
1   Sets light to a certain default dim level (ie: 1-99%) when powered on

Parameter Number

Parameter Size

Parameter Name

Description

13 1 Default Level (Z-Wave) – Light Default level for the dimmer when it is powered on from a Z-Wave command. A setting of 0 means that the switch will return to the level that it was on before it was turned off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 99 No No No

Value

 

Description

0   Sets back to light level prior to switch turning off - via Z-Wave Command
1   Sets light to a certain default dim level (ie: 1-99%) when powered on - via Z-Wave Command

Parameter Number

Parameter Size

Parameter Name

Description

14 1 Default Level (Local) – Fan Default level for the fan when it is powered on from the local switch. A setting of 0 means that the switch will return to the level that it was on before it was turned off

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 99 No No No

Value

 

Description

0   Sets back to fan level prior to switch turning off
1   Sets fan to a certain default dim level (ie: 1-99%) when powered on

Parameter Number

Parameter Size

Parameter Name

Description

15 1 Default Level (Z-Wave) – Fan Default level for the fan when it is powered on from a Z-Wave command. A setting of 0 means that the switch will return to the level that it was on before it was turned off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 99 No No No

Value

 

Description

0   Sets back to fan level prior to switch turning off - Z-Wave
1   Sets fan to a certain default dim level (ie: 1-99%) when powered on - Z-Wave

Parameter Number

Parameter Size

Parameter Name

Description

16 1 State After Power Restored – Light The state the switch should return to once power is restored after power failure. 0 = off, 1-99 = level, 100=previous

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

100 0 100 No No No

Value

 

Description

0   Off
1   Turns on to a certain percentage (1-99%)
100   Returns to previous state the light was in prior to a power outage

Parameter Number

Parameter Size

Parameter Name

Description

17 1 State After Power Restored – Fan The state the switch should return to once power is restored after power failure. 0 = off, 1-99 = level, 100=previous.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 100 No No No

Value

 

Description

0   Off
1   Turns on to a certain percentage (1-99%)
100   Returns to previous state the fan was in prior to power outage

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Default LED Strip Color – Light This is the color of the Light LED strip represented as part of the HUE color wheel. Since the wheel has 360 values and this parameter only has 255, the following equation can be used to determine the color: value/255 * 350 = Hue color wheel value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

170 0 255 No No No

Value

 

Description

0   Color values

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Default LED Strip Intensity – Light This is the intensity of the LED strip.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 9 No No No

Value

 

Description

0   Intensity of the LED strip

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Dimming Speed (From Switch) - Light This changes the speed in which the attached light dims up or down when controlled from the physical switch. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 0 99 No No No

Value

 

Description

0   Speed at which light dims up and down (from switch)
99   Sync to Parameter 1

Parameter Number

Parameter Size

Parameter Name

Description

20 1 Default LED Strip Color – Fan This is the color of the Fan LED strip represented as part of the HUE color wheel. Since the wheel has 360 values and this parameter only has 255, the following equation can be used to determine the color: value/255 * 350 = Hue color wheel value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

170 0 255 No No No

Value

 

Description

0   Color values

Parameter Number

Parameter Size

Parameter Name

Description

21 1 Default LED Strip Intensity – Fan This is the intensity of the fan LED strip.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 0 9 No No No

Value

 

Description

0   Intensity of the Fan LED strip

Parameter Number

Parameter Size

Parameter Name

Description

22 1 Default LED Strip Intensity (When OFF) – Light This is the intensity of the Light LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 9 No No No

Value

 

Description

0   Intensity of the Light LED strip (when lights are off)

Parameter Number

Parameter Size

Parameter Name

Description

23 1 Default LED Strip Intensity (When OFF) – Fan This is the intensity of the Fan LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 9 No No No

Value

 

Description

0   Intensity of the Fan LED strip (when fan is off)

Parameter Number

Parameter Size

Parameter Name

Description

24 4 LED Strip Effect – Light This will allow you to add some sweet effects to your LED Bar (i.e.: pulse, chase, solid, etc). Byte 1 = Color, Byte 2 = Brightness Level, Byte 3 = Effect, Byte 4 = Duration. *Please see website for further instructions on how to set this up

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 4294967295 No No No

Value

 

Description

0   Please see website instructions to set this up: https://nathanfiscus.github.io/inovelli-notification-calc/

Parameter Number

Parameter Size

Parameter Name

Description

25 4 LED Strip Effect – Fan This will allow you to add some sweet effects to your LED Bar (i.e.: pulse, chase, solid, etc). Byte 1 = Color, Byte 2 = Brightness Level, Byte 3 = Effect, Byte 4 = Duration. *Please see website for further instructions on how to set this up

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 4294967295 No No No

Value

 

Description

0   Please see website instructions to set this up: https://nathanfiscus.github.io/inovelli-notification-calc/

Parameter Number

Parameter Size

Parameter Name

Description

26 1 Timeout for LED Bar – Light When the LED strip is disabled (Light LED Strip Intensity is set to 0), this setting allows the LED strip to turn on temporarily while being adjusted.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 10 No No No

Value

 

Description

0   Disabled
1   Intensity level

Parameter Number

Parameter Size

Parameter Name

Description

27 1 Name: Timeout for LED Bar – Fan When the LED strip is disabled (Fan LED Strip Intensity is set to 0), this setting allows the LED strip to turn on temporarily while being adjusted.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 10 No No No

Value

 

Description

0   Disabled
1   Intensity Level

Parameter Number

Parameter Size

Parameter Name

Description

28 1 Active Power Reports The power level change that will result in a new power report being sent. The value is a percentage of the previous report. 0 = disabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 0 100 No No No

Value

 

Description

0   Disabled
1   Percentage of the previous report

Parameter Number

Parameter Size

Parameter Name

Description

29 2 Periodic Power & Energy Reports Time period between consecutive power & energy reports being sent (in seconds). The timer is reset after each report is sent

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3600 0 32767 No No No

Value

 

Description

0   Disabled
1   Seconds

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Ramp Rate This changes the speed in which the attached light turns on or off. For example, when a user sends the switch a basicSet(value: 0xFF) or basicSet(value: 0x00), this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 0 99 No No No

Value

 

Description

1   Speed at which the light turns on and off
99   Sync to Parameter 1

Parameter Number

Parameter Size

Parameter Name

Description

30 1 Energy Reports Energy level change which will result in sending a new energy report. Available settings: 1-127 (0.01-1.27 kWh) 0 = disabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 0 100 No No No

Value

 

Description

0   Disabled
1   Percentage of the previous report

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Ramp Rate (From Switch) This changes the speed in which the attached light turns on or off from the physical switch. For example, when a user presses the up or down button, this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 0 99 No No No

Value

 

Description

0   Speed at which the light turns on and off (from switch)
99   Sync to Parameter 1

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Minimum Level – Light The minimum level that the dimmer allows the bulb to be dimmed to. Useful when the user has a bulb that does not turn on at a lower level.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 45 No No No

Value

 

Description

1   Minimum % level the bulb can be dimmed down to

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Maximum Level – Light The maximum level that the dimmer allows the bulb to be dimmed to. Useful when the user has an LED bulb that reaches its maximum level before the dimmer value of 99.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 55 99 No No No

Value

 

Description

55   Maximum % level the bulb can be dimmed up to

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Minimum Level – Fan The minimum level that the dimmer allows the fan to be dimmed to. Useful when the user has a fan that does not turn on at a lower level.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 45 No No No

Value

 

Description

1   Minimum % level the fan can be dimmed down to

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Name: Maximum Level – Fan The maximum level that the dimmer allows the fan to be dimmed to.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 55 99 No No No

Value

 

Description

55   Maximum % level the fan can be dimmed up to

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Invert Switch Inverts the switch (Tap Down = On, Tap Up = Off). 0 = Disabled, 1 = Enabled

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Disabled