There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | LCD invert | 0 (Default) |
Normal orientation | |
1 | LCD content inverted | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | LCD Timeout | 0 (Default) |
LCD always on | |
5 to 30 | LCD timeout in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Backlight | 0 | Backlight disabled | |
1 (Default) |
Backlight enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Battery report | 0 | Battery reporting disabled | |
1 (Default) |
Battery reporting enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Measured temperature report | 0 | Reporting disabled | |
1 to 50 (Default) |
Reporting Delta in 1/10 Celcius | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Valve percentage report | 0 (Default) |
Reporting disabled | |
1 to 100 | Reporting Delta in percent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Window open detection | 0 | Detection disabled | |
1 to 3 (Default) |
Sensitivity level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Measured temperature offset | -128 | Temperature is supplied externaly | |
-50 to 50 (Default) |
Offset in 1/10 Celcius | ||||