There are over 4400 interoperable
Group ID | Group Profile Name | Profile | Maximum Nodes | Description | Endpoint ID | Commands |
---|---|---|---|---|---|---|
1 | Lifeline | 5 | 1. Send Command Class "Device Reset Locally Notification V1" to associated devices of this group to report factory reset information when factory reset the remote control. 2. When remote control battery power value changes, send Command Class "Battery Report V1" to associated devices of this group to report power value information. 3. Short press or press and hold down any button to send scene activation command to the associated devices of this group using Command Class “Central Scene Notification V3” | 0 | ||
2 | Launch 1 | 5 | 1. Short press I1 / O1 button of Group 2 to send ON/OFF command to associated devices of this group using Command Class "Basic Set V2". 2. Press and hold down I1 / O1 button of Group 2 to send light intensity increase/decrease command to associated devices of this group using Command Class "Multilevel V4". 3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20. 4. Press and hold down Scene button S1/S2, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20. | 0 | ||
3 | Launch 2 | 5 | 1. Short press I2 / O2 button of Group 3 to send ON/OFF command to associated devices of this group using Command Class "Basic Set V2". 2. Press and hold down I2 / O2 button of Group 3 to send light intensity increase/decrease command to associated devices of this group using Command Class "Multilevel V4". 3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20. 4. Press and hold down Scene button S1/S2, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20. | 0 | ||
4 | Launch 3 | 5 | 1. Short press I3 / O3 button of Group 4 to send ON/OFF command to associated devices of this group using Command Class "Basic Set V2". 2. Press and hold down I3 / O3 button of Group 4 to send light intensity increase/decrease command to associated devices of this group using Command Class "Multilevel V4". 3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20. 4. Press and hold down Scene button S1/S2, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20. | 0 | ||
5 | Launch 4 | 5 | 1. Short press I4 / O4 button of Group 5 to send ON/OFF command to associated devices of this group using Command Class "Basic Set V2". 2. Press and hold down I4 / O4 button of Group 5 to send light intensity increase/decrease command to associated devices of this group using Command Class "Multilevel V4". 3. Short press Scene button S1/S2, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20. 4. Press and hold down Scene button S1/S2, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20. | 0 |