Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Wiring type | 0 (Default) |
unknown | |
1 | 2 Wire With No Neutral | ||||
2 | 3 Wire With Neutral | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Load type | 0 (Default) |
unknown | |
1 | resistive | ||||
2 | inductive | ||||
3 | capacitive | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Enable/disable over current protection | 0 | disable | |
1 (Default) |
enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | Power automatic report absolute threshold, unit is W | 0 to 32767 (Default) |
When power changes above the absolute threshold, immediately report current power value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Power automatic report percentage threshold, unit is % | 0 to 100 (Default) |
When power changes above the percentage threshold, immediately report current power value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Saving load state before power failure | 0 | shutoff load | |
1 | turn on load | ||||
2 (Default) |
save load state before power failure | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 4 | Power metering automatic report time cycle, unit is second | 5 to 2678400 (Default) |
Power metering automatic report time cycle, unit is second | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 4 | Energy metering automatic report time cycle, unit is second | 5 to 2678400 (Default) |
Energy metering automatic report time cycle, unit is second | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 4 | Voltage metering automatic report time cycle, unit is second | 5 to 2678400 (Default) |
Voltage metering automatic report time cycle, unit is second | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 4 | Current metering automatic report time cycle, unit is second | 5 to 2678400 (Default) |
Current metering automatic report time cycle, unit is second | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Enable/disable to send the basic report | 0 | Disable to send Basic report | |
1 (Default) |
Enable to send Basic report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 1 | Setting dimming curve | 0 (Default) |
linear dimming | |
1 | logarithmic dimming | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 1 | Setting startup brightness of the load | 0 to 99 (Default) |
Setting startup brightness of the load | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Default fade time | 0 | Instantly | |
1 to 127 (Default) |
1 second (0x01) to 127 seconds (0x7F) in 1 second resolution. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Setting minimum brightness value | 0 to 50 (Default) |
the bigger the value is, the higher the load’s minimum brightness is | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Setting maximum brightness value | 0 to 100 (Default) |
the maximum brightness value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Choose MOSFET driving type | 0 (Default) |
trailing edge | |
1 | leading edge | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | External switch type | 0 (Default) |
Push button switch | |
1 | normal on/off switch | ||||
2 | 3-way switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Enable/disable external switch to be added to and removed from a network | 0 | disable | |
1 (Default) |
enable | ||||