Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: DIMMER 2 400W (DIMMER 2 400W)

Z-Wave Certification Number: ZC10-20076932


Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Wiring type 0
(Default)
unknown
  1 2 Wire With No Neutral
  2 3 Wire With Neutral

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Load type 0
(Default)
unknown
  1 resistive
  2 inductive
  3 capacitive

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Enable/disable over current protection 0 disable
  1
(Default)
enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 Power automatic report absolute threshold, unit is W 0 to 32767
(Default)
When power changes above the absolute threshold, immediately report current power value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Power automatic report percentage threshold, unit is % 0 to 100
(Default)
When power changes above the percentage threshold, immediately report current power value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Saving load state before power failure 0 shutoff load
  1 turn on load
  2
(Default)
save load state before power failure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 4 Power metering automatic report time cycle, unit is second 5 to 2678400
(Default)
Power metering automatic report time cycle, unit is second

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 4 Energy metering automatic report time cycle, unit is second 5 to 2678400
(Default)
Energy metering automatic report time cycle, unit is second

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 4 Voltage metering automatic report time cycle, unit is second 5 to 2678400
(Default)
Voltage metering automatic report time cycle, unit is second

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 4 Current metering automatic report time cycle, unit is second 5 to 2678400
(Default)
Current metering automatic report time cycle, unit is second

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Enable/disable to send the basic report 0 Disable to send Basic report
  1
(Default)
Enable to send Basic report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 1 Setting dimming curve 0
(Default)
linear dimming
  1 logarithmic dimming

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 1 Setting startup brightness of the load 0 to 99
(Default)
Setting startup brightness of the load

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Default fade time 0 Instantly
  1 to 127
(Default)
1 second (0x01) to 127 seconds (0x7F) in 1 second resolution.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Setting minimum brightness value 0 to 50
(Default)
the bigger the value is, the higher the load’s minimum brightness is

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Setting maximum brightness value 0 to 100
(Default)
the maximum brightness value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Choose MOSFET driving type 0
(Default)
trailing edge
  1 leading edge

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 External switch type 0
(Default)
Push button switch
  1 normal on/off switch
  2 3-way switch

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Enable/disable external switch to be added to and removed from a network 0 disable
  1
(Default)
enable