Z-Wave Products

There are over 4386 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Custos Ball Valve Servo (BVSZWE)

Z-Wave Certification Number: ZC12-21020179


Parameter Number

Parameter Size

Parameter Name

Description

17 1 Inverse Water Valve Report Inverses Switch Binary Report when Water Valve = 0x00 “Valve doesn’t let the water run through in Notification and real physical status.”

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Disable: 0x00 = does not let water run through, 0xFF = let water run through. Based on Configuration CC setting 0x12 & 0x13
1 (2)   Enable: 0x00 = let water run through, 0xFF = does not let water run through Based on Configuration CC setting 0x12 & 0x13

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Association Group 2 SET Value Configure Association Group 2 Basic Set value when Binary Switch Report = 0xFF *(Related to Configuration setting 0x11)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Basic Set (Send nothing)
1 (2)   Basic ON (0xFF)
2 (4)   Basic OFF (0x00)

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Association Group 2 SET Value Configure Association Group 2 Basic Set value when Binary Switch Report = 0x00 *(Related to Configuration setting 0x11)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Basic Set (Send nothing)
1 (2)   Basic ON (0xFF)
2 (4)   Basic OFF (0x00)

Parameter Number

Parameter Size

Parameter Name

Description

33 1 Temperature Report Unit Configure Temperature Unit report. The default Unit is depended on Regional Frequency Setting. (By default, US=°F and EU=°C)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Auto Temperature Report
1 (2)   Report Celsius °C unit
2 (4)   Report Fahrenheit °F unit

Parameter Number

Parameter Size

Parameter Name

Description

34 2 Temperature Threshold Change Configure Temperature threshold changed and send auto report

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

260 0 511 No No No

Value

 

Description

0   Higher Byte set to x0 represents Celsius °C unit
256   Higher Byte set to x1 represents Fahrenheit °F unit

Parameter Number

Parameter Size

Parameter Name

Description

35 2 Temperature Report Offset Configure Temperature Offset degree; Higher byte 0x = Positive degree and 1x= Negative degree.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

256 0 4607 No No No

Value

 

Description

0   0x0000 ~ 0x00FF, (0 ~ +255); Higher Byte 00 = Positive Celsius “+°C” e.g. 0x0002 = +2°C
256   0x0100 ~ 0x01FF, (0 ~ +255); Higher Byte 01 = Positive Fahrenheit “+°F” e.g. 0x010A = +10°F
4096   0x1000 ~ 0x10FF, (-0 ~ -255); Higher Byte 10 = Negative Celsius “-°C” e.g. 0x0002 = -2°C
4352   0x1100 ~ 0x11FF, (-0 ~ -255); Higher Byte 10 = Negative Fahrenheit “-°F” e.g. 0x110A = -10°F

Parameter Number

Parameter Size

Parameter Name

Description

36 2 Overheat Trigger Value Configure Overheat report trigger value. “Higher byte 0x00 represents Celsius °C unit, 0x01 represents Fahrenheit °F unit

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

360 0 511 No No No

Value

 

Description

0   From 0°C to 255°C
256   From 0°F to 255°F

Parameter Number

Parameter Size

Parameter Name

Description

37 2 Overheat Recover value Configure Overheat Recover report value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

342 0 511 No No No

Value

 

Description

0   From 0°C to 255°C
256   From 0°F to 255°F

Parameter Number

Parameter Size

Parameter Name

Description

38 1 Association Group 4 Overheat Trigger Configure Overheat Trigger Value in Association Group 4

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Basic Set (Send nothing)
1 (2)   Send Basic ON (0xFF)
2 (4)   Send Basic OFF (0x00)

Parameter Number

Parameter Size

Parameter Name

Description

39 1 Association Group 4 Overheat Cancel Configure Overheat Cancellation SET value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Basic Set (Send Nothing)
1 (2)   Send Basic ON (0x0FF)
2 (4)   Send Basic OFF (0x00)

Parameter Number

Parameter Size

Parameter Name

Description

40 2 Freeze Trigger Value Configure Freeze Trigger Report value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

288 0 511 No No No

Value

 

Description

0   From 0°C to 255°C
256   From 0°F to 255°F

Parameter Number

Parameter Size

Parameter Name

Description

41 2 Freeze Recover Value Configure Freeze Recover Report Value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

292 0 511 No No No

Value

 

Description

0   From 0°C to 255°C
256   From 0°F to 255°F

Parameter Number

Parameter Size

Parameter Name

Description

42 1 Freeze Detection Valve Control Enable / Disable Valve Control during Freeze when Water Leak is detected “Detected by built-in temperature sensor. Refer to Configuration CC parameter 0x28 (41) & 0x29 (42)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Ignore / Allowed to control Water Valve during Freeze detection
1 (2)   Forbidden to control Water Valve during Freeze detection

Parameter Number

Parameter Size

Parameter Name

Description

43 1 Association Group 5 Freeze Trigger Configure Association Group 5 Freeze Detection Trigger Basic Set value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Basic Set (Send nothing)
1 (2)   Basic Set ON (0xFF)
2 (4)   Basic Set OFF (0x00)

Parameter Number

Parameter Size

Parameter Name

Description

44 1 Association Group 5 Freeze Cancel Configure Association Group 5 Freeze Detection Cancellation Basic Set value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Basic Set (Send nothing)
1 (2)   Basic Set ON (0xFF)
2 (4)   Basic Set OFF (0x00)

Parameter Number

Parameter Size

Parameter Name

Description

49 1 Association Group 3 Water Leak Trigger Configure Association Group 3 Water Leak Trigger Basic Set value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Basic Set (Send nothing)
1 (2)   Basic Set ON (0xFF)
2 (4)   Basic Set OFF (0x00)

Parameter Number

Parameter Size

Parameter Name

Description

50 1 Association Group 3 Water Leak Cancel Configure Association Group Water Leak Cancellation Basic Set value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Bit (Value)

 

Description

0 (1)   Disable Basic Set (Send nothing)
1 (2)   Basic Set ON (0xFF)
2 (4)   Basic Set OFF (0x00)

Parameter Number

Parameter Size

Parameter Name

Description

51 1 Water Leak Detection Valve Control Disable / Enable Valve Control when Water Leak detected

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Disable to control Water Valve when Water Leak is detected
1 (2)   Enable to control Water Valve when Water Leak is detected

Parameter Number

Parameter Size

Parameter Name

Description

65 1 Buzzer Enable / Disable Built-in Buzzer Sound

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Disable Buzzer
1 (2)   Enable Buzzer

Parameter Number

Parameter Size

Parameter Name

Description

66 1 LED Brightness Level Configure Built-in LED Brightness Level

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

80 0 99 No No No

Value

 

Description

0   Set Brightness Level from 0% ~ 99%

Parameter Number

Parameter Size

Parameter Name

Description

67 1 Touch Keylock Protection Disable / Enable Touch Keylock Protection

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Bit (Value)

 

Description

0 (1)   Disable Keylock Protection
1 (2)   Enable Keylock Protection

Parameter Number

Parameter Size

Parameter Name

Description

81 1 Notification Report Configure Notification Report in Association Group 1 Lifeline “Set Bit to 0 = Disable, Set Bit to 1 = Enable” Default value 0x0D (13) Only available values as below xxxx xxx0 = Disable to report valve Open / Close status xxxx xxx1 = Enable to report valve Open / Close status (Default) xxxx xx0x = Disable Overheat Detection (Default) xxxx xx1x = Enable Overheat Detection xxxx x0xx = Disable Freeze (Underheat) Detection xxxx x1xx = Enable Freeze (Underheat) Detection (Default) xxxx 0xxx = Disable Water Leak Detection xxxx 1xxx = Enable Water Leak Detection (Default)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

13 0 15 No No No