TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | State After Power Restored | 0 (Default) |
Off | |
1 | On | ||||
2 | Returns to level before Power Outage | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Notification when Load status change | 0 | The function is disabled | |
1 (Default) |
Send Switch Multilevel Report . | ||||
2 | Send Switch Multilevel Report only when Load status is not changed by Z-WAVE Command | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Default dimming speed | 0 | instantly | |
1 | fast | ||||
100 | slow | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Enable or Disable external switch to pair network | 0 | Disable | |
1 (Default) |
Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Setting dimming way | 0 (Default) |
Linear dimming | |
1 | Logarithmic dimming | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Setting default brightness when turn on the dimmer from off status. | 0 (Default) |
the default brightness is 1% | |
1 to 99 | Default brightness percentage (where 99% = 100% brightness) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Setting delay time when turn off | 0 (Default) |
the light turns off immediately | |
1 to 60 | Amount of time in seconds after which the light turns off | ||||