Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Luxy Smart Light (ZMNHQD1)

Z-Wave Certification Number: ZC10-20096982


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Parameter no. 1 – Digital input type 0 Push-button
  1
(Default)
ON/OFF toggle switch
  2 Motion sensor
  3 Motion sensor with memory (turned off after certain amount of time defined in parameter 5)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Parameter no. 10 – Auto on timer 0
(Default)
disabled
  30 to 32353 30 – 32535 seconds after which the device turns on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Parameter no. 11 – Auto off timer 0 disabled
  30 to 32535
(Default)
30 – 32535 seconds after which the device turns off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Parameter no. 3 – Turning off alarming 0 only by z-wave command (basic set, switch multilevel set, switch multilevel start/stop level change, sound switch play tone, sound switch configuration, switch color set, switch color start/stop level change, notification report idle)
  1
(Default)
capacitive input or z-wave command (basic set, switch multilevel set, switch multilevel start/stop level change, sound switch play tone, sound switch configuration, switch color set, switch color start/stop level change, notification report idle)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Parameter no. 30 – Restore state on power failure 1
(Default)
enabled (the device will restore state on power failure)
  0 – disabled (the device will not restore state on power failure and will remain off)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Parameter no. 5 – Motion sensor memory timer 0 to 32534
(Default)
0-32534 seconds after which the LED will be turned off.
  32535 never turns off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

50 1 Parameter no. 50 – Beeper enable/disable 0 disabled (the beeper is not active)
  1
(Default)
enabled (the beeper is active)