There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Strips Guard 700 (11 01 026)

Z-Wave Certification Number: ZC12-20080091


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Notification type Select the notification type for the door and window open or close events.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   Binary sensor report + Notification report (Access Control)
1 (2)   Notification report (Access Control)
2 (4)   Notification report (Home Security)

Parameter Number

Parameter Size

Parameter Name

Description

15 1 Activate supervision Activate Supervision command for only important alarm events or all events. Supervised commands require a confirmation from the gateway when a notification is received.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   Events sent with S2 Encapsulation only
1 (2)   Only Door Open Alarm Report (Events sent with S2 and supervision encapsulation)
2 (4)   Unsolicited reports (Door Open/Close, Tamper clear, Wake-up notification and Battery Report events sent with S2 and supervision encapsulation)

Parameter Number

Parameter Size

Parameter Name

Description

16 2 Supervision report wait time Only used if parameter 22 is set to 1 (High security). The number of milliseconds to wait for a Supervision response when a Supervised message is sent.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10000 500 30000 No No Yes

Value

 

Description

500   (ms)

Parameter Number

Parameter Size

Parameter Name

Description

17 1 No. of failed event retries Only used if parameter 22 is set to 1 (High security). Number of retries when a confirmation is not received.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 5 No No Yes

Value

 

Description

0   0 = No retry, 1 - 5 = Number of retries when a confirmation is not received.

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Failed Event Retry Interval Only used if parameter 22 is set to 1 (High security). The minimum number of seconds between retries.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 1 60 No No Yes

Value

 

Description

1   Min = 1 second, Max = 60 seconds

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Heartbeat interval Only used if parameter 22 is set to 1 (High security). Number of minutes between periodic battery reports (Heartbeats).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

70 5 70 No No Yes

Value

 

Description

5   (mins) - Accepts multiples of 5 mins. - Any arbitary value in between 5 and 70 will be rounded up to a multiple of 5

Parameter Number

Parameter Size

Parameter Name

Description

2 1 LED indication Turn On or Off LED for specific event indications (ex. alarms).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

0 (1)   Turns off LED for door open events
1 (2)   On

Parameter Number

Parameter Size

Parameter Name

Description

22 1 Security Level Select the level of security.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No Yes

Bit (Value)

 

Description

0 (1)   : Standard (Forces parameter behaviour as follows: #16=1000, #17=Sensative standard**, #18=0, #19=Off, #21=Off ** Retries with an incrementally longer period until reconnected
1 (2)   : High Security (Enables parameters 16-19, 21)