Z-Wave Products

There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Module (FGS-214)

Z-Wave Certification Number: ZC10-20086957


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Remember relays state 0 relays remain switched off after restoring power
  1
(Default)
restore remembered state of relays after restoring power
  2 restore remembered state of relays after restoring power, but for toggle switches (parameter 20/21 set to 1) set the same state as the current state of the switches

Parameter Number

Parameter Size

Parameter Name

Parameter Values

150 1 First channel – operating mode 0
(Default)
standard operation
  1 delayed OFF
  2 auto OFF
  3 flashing

Parameter Number

Parameter Size

Parameter Name

Parameter Values

152 1 First channel – reaction to input change in delayed/ auto OFF modes 0
(Default)
cancel mode and set default state
  1 no reaction, mode runs until it ends
  2 reset timer, start counting time from the beginning

Parameter Number

Parameter Size

Parameter Name

Parameter Values

154 2 First channel – time parameter for delayed/auto OFF and flashing modes 0 0.1 seconds
  1 to 32000
(Default)
0.1-3200 seconds, 0.1s step

Parameter Number

Parameter Size

Parameter Name

Parameter Values

156 2 S1 input – Switch ON value sent to 2nd association group 0 turn off
  1 to 99 turn on and set level
  255
(Default)
turn on with last level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

157 2 S1 input – Switch OFF value sent to 2nd association group 0
(Default)
turn off
  1 to 99 turn on and set level
  255 turn on with last level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

158 2 S1 input – Double Click value sent to 2nd association group 0 turn off
  1 to 99
(Default)
turn on and set level
  255 turn on with last level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

162 1 Q/Q1 output type 0
(Default)
Normally Open (relay contacts opened turned off, closed when turned on)
  1 Normally Closed (relay contacts closed turned off, opened when turned on)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 S1 input – switch type 0
(Default)
momentary switch
  1 toggle switch synchronized (contact closed - ON, contact opened - OFF)
  2 toggle switch with memory (device changes status when switch changes status)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 S2 input – switch type 0
(Default)
momentary switch
  1 toggle switch synchronized (contact closed - ON, contact opened - OFF)
  2 toggle switch with memory (device changes status when switch changes status)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Inputs orientation 0
(Default)
default (S1 - 1st channel, S2 - 2nd channel)
  1 reversed (S1 - 2nd channel, S2 - 1st channel)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 4 Alarm configuration - 1st slot 0 to 255
(Default)
[LSB] – action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647 [MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 4 Alarm configuration - 2nd slot 0 to 255 [LSB] – action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647
(Default)
[MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 4 Alarm configuration - 3rd slot 0 to 255 [LSB] – action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647
(Default)
[MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 4 Alarm configuration - 4th slot 0 to 255 [LSB] – action
  255 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647
(Default)
[MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 4 Alarm configuration - 5th slot 0 to 255 [LSB] – action
  256 to 65535 Event/State Parameters
  65536 to 16777215 Notification Status
  16777216 to 2147483647
(Default)
[MSB] – Notification Type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

35 2 Alarm configuration – duration 0 infinite
  1 to 32400
(Default)
(1s-9h, 1s step) – duration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 S1 input – scenes sent 0 no scenes sent
  1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key hold down and key released
  15
(Default)
All active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 S2 input – scenes sent 0 no scenes sent
  1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key hold down and key released
  15
(Default)
All active