Z-Wave Products

There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Flood/Freeze Sensor (52247/ZW6309)

Z-Wave Certification Number: ZC12-20100126


Parameter Number

Parameter Size

Parameter Name

Description

19 2 Alternate Exclusion Alternative way to perform Exclusion

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No Yes No

From

 

To

Description

0   0 Press button once when prompted to remove device
1   1 Press the button three times quickly when prompted to remove device

Parameter Number

Parameter Size

Parameter Name

Description

21 2 Reverse Wet/Dry Detection Detection Mode(1:Wet 2:Dry)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 2 No Yes No

From

 

To

Description

1   1 Normal Detection (water detected)
2   2 Reverse Detection (Dry Detected)

Parameter Number

Parameter Size

Parameter Name

Description

22 2 Temp Report Freq.(Battery) Set Temp Report Freq.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

60 5 1440 No Yes No

From

 

To

Description

5   59 5... 59 minutes
60   60 Hourly
360   360 6 hours
720   720 12 hours
1440   1440 Daily

Parameter Number

Parameter Size

Parameter Name

Description

23 2 Battery Report Freq. Set Battery Report Freq.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1440 5 1440 No Yes No

From

 

To

Description

5   60 5... 60 minutes
360   360 Hourly
720   720 12 hours
1440   1440 Daily

Parameter Number

Parameter Size

Parameter Name

Description

50 2 Low Temp Alert Level Set Low Temp Level

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

33 -4 122 No Yes No

From

 

To

Description

-4   122 Low Temp

Parameter Number

Parameter Size

Parameter Name

Description

51 2 High Temp Alert Level Set High Temp Level

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

104 -4 122 No Yes No

From

 

To

Description

-4   122 High temp

Parameter Number

Parameter Size

Parameter Name

Description

52 2 Temp Report Freq.(USB) Set Temp Report Freq.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

60 5 360 No Yes No

From

 

To

Description

5   360 5... 360 Minutes - Sent every 5 minutes, up to 6 hours
60   60 Hourly

Parameter Number

Parameter Size

Parameter Name

Description

53 2 LED/Buzzer action during Tamper Event Set Tamper Indication 0 = no LED, no beep (Default) 1 = Red LED Flash 5x, no beep 2 = Red LED cont flash, no beep 3 = no LED, cont beep 4 = Red LED cont flash, cont beep

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 4 No Yes No

From

 

To

Description

0   0 No LED, No Beep
1   1 Red LED Flash 5x, no beep
2   2 Red LED continuous flash, no beep
3   3 No LED, continuous beep
4   4 Red LED continuous flash, continuous beep