19 | 2 | Alternate Exclusion | Alternative way to perform Exclusion | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | Yes | No |
From |
To |
Description |
|||
0 | 0 | Press button once when prompted to remove device | |||
1 | 1 | Press the button three times quickly when prompted to remove device | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
21 | 2 | Reverse Wet/Dry Detection | Detection Mode(1:Wet 2:Dry) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 2 | No | Yes | No |
From |
To |
Description |
|||
1 | 1 | Normal Detection (water detected) | |||
2 | 2 | Reverse Detection (Dry Detected) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
22 | 2 | Temp Report Freq.(Battery) | Set Temp Report Freq. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 5 | 1440 | No | Yes | No |
From |
To |
Description |
|||
5 | 59 | 5... 59 minutes | |||
60 | 60 | Hourly | |||
360 | 360 | 6 hours | |||
720 | 720 | 12 hours | |||
1440 | 1440 | Daily | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
23 | 2 | Battery Report Freq. | Set Battery Report Freq. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1440 | 5 | 1440 | No | Yes | No |
From |
To |
Description |
|||
5 | 60 | 5... 60 minutes | |||
360 | 360 | Hourly | |||
720 | 720 | 12 hours | |||
1440 | 1440 | Daily | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
50 | 2 | Low Temp Alert Level | Set Low Temp Level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
33 | -4 | 122 | No | Yes | No |
From |
To |
Description |
|||
-4 | 122 | Low Temp | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
51 | 2 | High Temp Alert Level | Set High Temp Level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
104 | -4 | 122 | No | Yes | No |
From |
To |
Description |
|||
-4 | 122 | High temp | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
52 | 2 | Temp Report Freq.(USB) | Set Temp Report Freq. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 5 | 360 | No | Yes | No |
From |
To |
Description |
|||
5 | 360 | 5... 360 Minutes - Sent every 5 minutes, up to 6 hours | |||
60 | 60 | Hourly | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
53 | 2 | LED/Buzzer action during Tamper Event | Set Tamper Indication 0 = no LED, no beep (Default) 1 = Red LED Flash 5x, no beep 2 = Red LED cont flash, no beep 3 = no LED, cont beep 4 = Red LED cont flash, cont beep | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 4 | No | Yes | No |
From |
To |
Description |
|||
0 | 0 | No LED, No Beep | |||
1 | 1 | Red LED Flash 5x, no beep | |||
2 | 2 | Red LED continuous flash, no beep | |||
3 | 3 | No LED, continuous beep | |||