Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: ZOE POWER H (HZ06100)

Z-Wave Certification Number: ZC10-20096969


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Parameter no. 1 – Input 1 switch type 0 mono-stable switch type (push button)
  1
(Default)
bi-stable switch type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Parameter no. 10 - Activate / deactivate functions ALL ON/ALL OFF 255
(Default)
ALL ON active, ALL OFF active
  0 ALL ON is not active ALL OFF is not active
  1 ALL ON is not active ALL OFF active
  2 ALL ON active ALL OFF is not active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Parameter no. 11 - Automatic turning off output Q1 after set time 0
(Default)
Auto OFF disabled
  1 to 32525 1second (0.01s) - 32535 seconds (325.35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 2 Parameter no. 110 – Temperature sensor offset settings 32526
(Default)
offset is 0.0C
  1 to 100 From 1 to 100 - value from 0.1 °C to 10.0 °C is added to actual measured temperature.
  1001 to 1100 From 1001 to 1100 - value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Parameter no. 12 - Automatic turning on output Q1 after set time 0
(Default)
Auto ON disabled
  1 to 32535 1second (0.01s) - 32536 seconds (325.35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Parameter no. 120 – Temperature sensor reporting 0
(Default)
Reporting disabled
  1 to 127 0.1°C – 12.7°C, step is 0.1°C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Parameter no. 13 - Automatic turning off output Q2 after set time 0
(Default)
Auto OFF disabled
  1 to 32535 1second (0.01s) - 32535 seconds (325.35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 Parameter no. 14 - Automatic turning on output Q2 after set time 0
(Default)
Auto ON disabled
  1 to 32535 1second (0.01s) - 32535 seconds (325.35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Parameter no. 15 - Automatic turning off / on seconds or milliseconds selection 0
(Default)
seconds selected
  1 milliseconds selected

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Parameter no. 2 – Input 2 switch type 0
(Default)
mono-stable switch type (push button)
  1 bi-stable switch type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Parameter no. 30 - Saving the state of the relays Q1 and Q2 after a power failure 0
(Default)
Zoe Power module saves its state before power failure (it returns to the last position saved before a power failure)
  1 Zoe Power module does not save the state after a power failure, it returns to "off" position

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Parameter no. 40 – Power reporting in Watts on power change for Q1 0 reporting disabled
  1 to 100
(Default)
1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 Parameter no. 41 – Power reporting in Watts on power change for Q2 0 Reporting Disabled
  1 to 100
(Default)
1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Parameter no. 42 – Power reporting in Watts by time interval for Q1 0 reporting disabled
  1 to 32525
(Default)
1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 2 Parameter no. 43 – Power reporting in Watts by time interval for Q2 0 reporting disabled
  1 to 32525
(Default)
1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

63 1 Parameter no. 63 – Output Q1 Switch selection 0
(Default)
When system is turned off the output is 0V (NC).
  1 When system is turned off the output is 230V (NO).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 1 Parameter no. 64 – Output Q2 Switch selection 0
(Default)
When system is turned off the output is 0V (NC).
  1 When system is turned off the output is 230V (NO).