TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Parameter no. 1 – Input 1 switch type | 0 | mono-stable switch type (push button) | |
1 (Default) |
bi-stable switch type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Parameter no. 10 - Activate / deactivate functions ALL ON/ALL OFF | 255 (Default) |
ALL ON active, ALL OFF active | |
0 | ALL ON is not active ALL OFF is not active | ||||
1 | ALL ON is not active ALL OFF active | ||||
2 | ALL ON active ALL OFF is not active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Parameter no. 11 - Automatic turning off output Q1 after set time | 0 (Default) |
Auto OFF disabled | |
1 to 32525 | 1second (0.01s) - 32535 seconds (325.35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 2 | Parameter no. 110 – Temperature sensor offset settings | 32526 (Default) |
offset is 0.0C | |
1 to 100 | From 1 to 100 - value from 0.1 °C to 10.0 °C is added to actual measured temperature. | ||||
1001 to 1100 | From 1001 to 1100 - value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Parameter no. 12 - Automatic turning on output Q1 after set time | 0 (Default) |
Auto ON disabled | |
1 to 32535 | 1second (0.01s) - 32536 seconds (325.35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Parameter no. 120 – Temperature sensor reporting | 0 (Default) |
Reporting disabled | |
1 to 127 | 0.1°C – 12.7°C, step is 0.1°C | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | Parameter no. 13 - Automatic turning off output Q2 after set time | 0 (Default) |
Auto OFF disabled | |
1 to 32535 | 1second (0.01s) - 32535 seconds (325.35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | Parameter no. 14 - Automatic turning on output Q2 after set time | 0 (Default) |
Auto ON disabled | |
1 to 32535 | 1second (0.01s) - 32535 seconds (325.35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Parameter no. 15 - Automatic turning off / on seconds or milliseconds selection | 0 (Default) |
seconds selected | |
1 | milliseconds selected | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Parameter no. 2 – Input 2 switch type | 0 (Default) |
mono-stable switch type (push button) | |
1 | bi-stable switch type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Parameter no. 30 - Saving the state of the relays Q1 and Q2 after a power failure | 0 (Default) |
Zoe Power module saves its state before power failure (it returns to the last position saved before a power failure) | |
1 | Zoe Power module does not save the state after a power failure, it returns to "off" position | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Parameter no. 40 – Power reporting in Watts on power change for Q1 | 0 | reporting disabled | |
1 to 100 (Default) |
1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Parameter no. 41 – Power reporting in Watts on power change for Q2 | 0 | Reporting Disabled | |
1 to 100 (Default) |
1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | Parameter no. 42 – Power reporting in Watts by time interval for Q1 | 0 | reporting disabled | |
1 to 32525 (Default) |
1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
43 | 2 | Parameter no. 43 – Power reporting in Watts by time interval for Q2 | 0 | reporting disabled | |
1 to 32525 (Default) |
1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 1 | Parameter no. 63 – Output Q1 Switch selection | 0 (Default) |
When system is turned off the output is 0V (NC). | |
1 | When system is turned off the output is 230V (NO). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
64 | 1 | Parameter no. 64 – Output Q2 Switch selection | 0 (Default) |
When system is turned off the output is 0V (NC). | |
1 | When system is turned off the output is 230V (NO). | ||||