There are over 4228 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Minimum Temperature change to report | This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | 1/10 degree | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | High Temperature Trigger BASIC Set Command Value | This defines what BASIC command shall be sent out into association group 2 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Low Humidity Trigger BASIC Set Command Value | This defines what BASIC command shall be sent out into association group 5 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | High Humidity Trigger BASIC Set Command Value | This defines what BASIC command shall be sent out into association group 4 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Offset value for Mould danger notification | This value allows to increase the humidity threshold for mold danger notification by max 10% | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 10 | No | No | No |
Value |
Description |
||||
0 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Minimum humidity change to report | This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be active. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 20 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
255 | 4 | Reset parameter | This parameter helps reset configuration parameters and the device to factory defaults. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1431655765 | No | No | No |
Value |
Description |
||||
1 | Reset all Parameter settings to their default settings. | ||||
1431655765 | Completely factory reset sensor and send device reset locally notification. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 2 | Temperature and Humidity Periodic Reports | This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
43200 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
900 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 2 | Temperature Upper Watermark value | This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1000 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | 1/10 degree | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 2 | Temperature Lower Watermark value | This parameter defines a temperature. If the measured temperature drops below this watermark a BASIC command is sent into Association Group 3 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1000 | No | No | No |
From |
To |
Description |
|||
0 | 0 | disabled | |||
200 | 1000 | 1/10 degree | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Humidity Upper Watermark value | This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 90 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Humidity Lower Watermark value | This parameter defines a relative humidity. If the measured temperature drops below this relative humidity a BASIC command is sent into Association Group 5 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 90 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Low Temperature Trigger BASIC Set Command Value | This defines what BASIC command shall be sent out into association group 3 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Values | ||||