There are over 4059 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Parameter 1 | 0 to 127 (Default) |
Value=0 indicates Turn off report , value>=1 indicates to report current PM2.5 value when change > n * 1ug/m3 | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Parameter 2 | 0 to 127 (Default) |
Value=0 indicates Turn off report , value>=1 indicates to report current CO2 value when change > n * 5ppm | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Parameter 3 | 0 to 127 (Default) |
Value=0 indicates Turn off report , value>=1 indicates to report current temperature value when change > n * 0.5℃ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Parameter 4 | 0 to 127 (Default) |
Value=0 indicates Turn off report , value>=1 indicates to report current humidity value when change >n% | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Parameter 5 | 0 to 127 (Default) |
Value=0 indicates Turn off report , value>=1-127*5ppb Report change | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Parameter 6 | 0 to 32767 (Default) |
Value=0 indicates Turn off report , value>=1 indicates to report current Illumination value when change >n*1 Lux | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Parameter 7 | 0 to 127 (Default) |
Value=0 indicates Turn off report , value>=1 indicates to report current Noise value when change >n*1 dB | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Parameter 8 | 0 to 1 (Default) |
Value=0 indicates Turn off report , value=1 indicates report change | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Parameter 9 | 0 to 1 (Default) |
Value=0 indicates Turn off report , value=1 indicates report change | |