Z-Wave Products

There are over 4059 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: 9 in 1 MULTI-SENSOR (A8-9)

Z-Wave Certification Number: ZC10-20096971


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Parameter 1 0 to 127
(Default)
Value=0 indicates Turn off report , value>=1 indicates to report current PM2.5 value when change > n * 1ug/m3

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Parameter 2 0 to 127
(Default)
Value=0 indicates Turn off report , value>=1 indicates to report current CO2 value when change > n * 5ppm

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Parameter 3 0 to 127
(Default)
Value=0 indicates Turn off report , value>=1 indicates to report current temperature value when change > n * 0.5℃

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Parameter 4 0 to 127
(Default)
Value=0 indicates Turn off report , value>=1 indicates to report current humidity value when change >n%

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Parameter 5 0 to 127
(Default)
Value=0 indicates Turn off report , value>=1-127*5ppb Report change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Parameter 6 0 to 32767
(Default)
Value=0 indicates Turn off report , value>=1 indicates to report current Illumination value when change >n*1 Lux

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Parameter 7 0 to 127
(Default)
Value=0 indicates Turn off report , value>=1 indicates to report current Noise value when change >n*1 dB

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Parameter 8 0 to 1
(Default)
Value=0 indicates Turn off report , value=1 indicates report change

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Parameter 9 0 to 1
(Default)
Value=0 indicates Turn off report , value=1 indicates report change