Z-Wave Products

There are over 4053 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Chime+Siren (ISZW7-ECO)

Z-Wave Certification Number: ZC12-20100128


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Default Sound Map Basic Set of 0xFF to play the sound number set here. e.g. a 1 is Siren and a 5 is a Chime.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 100 No No No

Value

 

Description

1   Different types of sounds

Parameter Number

Parameter Size

Parameter Name

Description

2 4 Heartbeat Notification Timing Seconds between automatic battery reports.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3600 120 86400 No No Yes

Value

 

Description

120   Seconds between automatic battery reports.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Supervision Encapsulation Encapsulate Unsolicited Notifications in Supervision Get requests. 0: Disabled 1: Enabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No Yes

Bit (Value)

 

Description

0 (1)   disabled
1 (2)   enabled

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Sound Volume Sound volume as a percentage for non-emergency sounds (See Configuration Parameter #6). 1 to 100, whereas 0 is Mute, and 255 is Restore last volume before Mute.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 0 100 No No No

Value

 

Description

0   Sound volume as a percentage for non-emergency sounds

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Sounds Available Number of sounds available to play.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

30 0 255 Yes No No

Value

 

Description

0   Number of sounds available to play.

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Emergency Sound Volume Adjustable Enable Intrusion/Smoke/CO siren volume adjustable and mutable. 0 is Disabled (default). 1 is Enabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No Yes

Bit (Value)

 

Description

0 (1)   disabled alarm type sounds volume adjustments
1 (2)   enable alarm type sounds volume adjustments