Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Locally Button function | 0 (Default) |
Up Button ON,Down Button OFF | |
1 | Up Button OFF,Down Button ON | ||||
2 | Up Button ON/OFF,Down Button ON/OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Multilevel minimum value can be set(The minimum luminance value of the dimming)(Local Button) | 0 to 99 (Default) |
The minimum luminance value of the dimming | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Multilevel maxmum value can be set(The maxmum luminance value of the dimming)(Local Button) | 0 to 99 (Default) |
the maxmum luminance value of the dimming | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | quickly press UPPER paddle 2 times | 0 (Default) |
Turn ON to 99 | |
1 | turn on to the value relate with parameter 11 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Double Tap Behavior | 0 (Default) |
enable double tap to full brightness | |
1 | disable double tap to full brightness,single tap to last brightness level | ||||
2 | disable double tap to full brightness,single tap always to full brightness | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Enable or Disable local control | 0 | disable | |
1 (Default) |
enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Status LED Configuration | 0 (Default) |
Output and the LED are in the different state | |
1 | Output and the LED are in the same state | ||||
2 | Always OFF | ||||
3 | Always ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Enable Auto Turn-Off Time | 0 (Default) |
disable | |
1 | enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 4 | Count Down Configuration | 1 to 65535 (Default) |
Auto Turn-Off this Timer | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Auto Turn-On Timer | 0 (Default) |
disable | |
1 | enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 4 | Auto Turn-On Timer | 1 to 65535 (Default) |
Auto Turn-On this Timer | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Association Setting Parameter | 0 | None | |
1 | Local | ||||
2 | 3-way | ||||
3 | 3-way&Local | ||||
4 | Z-Wave Hub | ||||
5 | Z-Wave hub&Local | ||||
6 | Z-Wave hub&3-way | ||||
7 | Z-Wave hub&Local&3-way | ||||
8 | Timer | ||||
9 | Timer&Local | ||||
10 | Timer&3-way | ||||
11 | Timer&3-way&Local | ||||
12 | Timer&Z-Wave hub | ||||
13 | Timer&Z-Wave hub&Local | ||||
14 | Timer&Z-Wave hub&3-way | ||||
15 (Default) |
All | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Restores state after power failure | 0 | Output OFF | |
1 | Output ON | ||||
2 (Default) |
The state before a power outage | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Dimmer Speed Parameter (Local Button) | 1 to 99 (Default) |
from 0x63 to 0x00 or from 0x00 to 0x63 need Value s | |