Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Close Interval | Used for auto calibration. Sets interval endpoint detection. Smaller interval will make the blinds close tighter. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
22 | 15 | 30 | No | No | No |
Value |
Description |
||||
15 | Smaller interval will make the blinds close tighter | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Reverse Direction | Used to reverse the direction of the blinds. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Forward Direction - 0% = Closed Down | ||||
1 | Reverse Direction - 0% = Closed Up | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Disable Report | Used to disable Z-Wave Report. This is useful for systems that poll iblinds immediately after sending a position command. Disable if this an immediate report is causing iblinds motor to function improperly. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Enable Device Reset Locally | ||||
1 | Disable Device Reset Locally | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Default ON Value | Used to set the default ON Level when manual push button is pushed- Default value for ON = 50% (0x32) , change this value if you wish to set the push button ON value to a different preset value. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | Set the default On Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Reserved | Reserved for Manufactuer | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Reserved for Manufactuer | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Speed | Used to set the default blind Speed. 0= No Delay. The Larger the number the slower the speed. Note: Duration Value >0 will always override the speed parameter | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | The larger the value the slower the speed | ||||