TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Select Button reports | Configure reports sent when pressing buttons: 0 - Send Central Scene Command only 1 - Send Group Association Command only 2 - Send Central Scene and Group Association Commands | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Send Central Scene Command only | ||||
1 (2) | Send Group Association Command only | ||||
2 (4) | Send Central Scene and Group Association Commands | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Enable LED | 0 disable,1 enable | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disabled (does not turn off factory reset/learn mode blinking etc) | ||||
1 (2) | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Active Button rockers | If there is issue where, single button accidently presses other buttons, customer can turn of different button groups. Not needed if plasic design already prevents this. 1 = Buttongroup 3 is used (when sigle rocker is used) 2 = Buttongroup 2 & 4 is used (when double rocker is used) 3 = Buttongroup 2, 3 & 4 is used (when triple rocker is used) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 1 | 3 | No | No | No |
Bit (Value) |
Description |
||||
1 (2) | Buttongroup 3 is used (when sigle rocker is used) | ||||
2 (4) | Buttongroup 2 & 4 is used (when double rocker is used) | ||||
3 (8) | Buttongroup 2, 3 & 4 is used (when triple rocker is used) | ||||