There are over 4401 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Radio Switch Shutter Plus (MTSWIS-101-WL)

Z-Wave Certification Number: ZC10-21027009


Parameter Number

Parameter Size

Parameter Name

Description

1 2 Heartbeat rate A heartbeat notification is sent at this rate

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

60 1 1440 No No No

Value

 

Description

1   Heartbeat rate [min]

Parameter Number

Parameter Size

Parameter Name

Description

2 2 Full distance down drive time Time the blind uses to drive from upper end position to the lower end position.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 30000 Yes No No

Value

 

Description

0   Full distance down drive time [0.01s]

Parameter Number

Parameter Size

Parameter Name

Description

3 2 Full distance up drive time Time the blind uses to drive from lower end position to the upper end position.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 30000 Yes No No

Value

 

Description

0   Full distance up drive time [0.01s]

Parameter Number

Parameter Size

Parameter Name

Description

4 2 Time to move slat between horizontal and vertivcal Time to move slat between horizontal and vertivcal

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

120 0 500 No No No

Value

 

Description

0   Slat move time [0.01s]

Parameter Number

Parameter Size

Parameter Name

Description

5 2 Start position calibration Start a positioning calibration. Used to start to measure time used by blind to move from one end position to the other.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Position calibration is inactive / has ended
1   Start Position calibration / position calibration is active

Parameter Number

Parameter Size

Parameter Name

Description

6 2 Invert outputs Normaly output 1 is used to drive blind upwards and output 2 to drive it downwards. When parameter is set to 1 output 1 drives blind downwards and output 2 upwards.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Normal assignment of outputs
1   Inverted assignment of outputs

Parameter Number

Parameter Size

Parameter Name

Description

7 2 Min off time of outputs When blind should change direction while running, the time defined in this parameter is used between stopping active direction output and starting oposite direction output.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 10 50 No No No

Value

 

Description

10   Minimum off time of one output before turning on other one [0.01s]

Parameter Number

Parameter Size

Parameter Name

Description

8 2 Key assignment local control Digital inputs and Touch add-on may be used to control blinds locally. Different key pairs can be assigned to control blind to move up or down resp.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 6 No No No

Value

 

Description

0   Locol control of blinds disabled
1   Input 1 --> up, input 2 --> down
2   Input 1 --> down, input 2 --> up
3   Touch 2 --> up, touch 4 --> down
4   Touch 3 --> up, touch 5 --> down
5   Touch 2 --> left, touch 3 --> right
6   Touch 4 --> left, touch 5 --> right

Parameter Number

Parameter Size

Parameter Name

Description

9 2 Key hold time to move to end position When key is hold shorter time than parameter value, movement stops, when key is released. If key is hold longer than parameter value, blind moves until reaching end position also when key is released.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 0 50 No No No

Value

 

Description

0   Key hold time to move to end position [0.1s]