Group ID | Group Profile Name | Profile | Maximum Nodes | Description | Endpoint ID | Commands |
---|---|---|---|---|---|---|
1 | Lifeline | 0x0001 | 5 | Device Reset Locally: When factory reset. Notification Report: See Notification Chapter for more information. Sensor Binary Report: See Param5 for more information. Sensor Multilevel Report: When sensors above over limit or below under limit. Battery Report: See Param101. Indicator Report: Issued when the indicator light changed | 0 | |
2 | Motion | 0x7107 | 5 | Basic Set Command will be sent to the associated device when motion trigger or untrigger. The basic set value is determined by Param11, Param12. See Param13 for more information. | 0 | |
3 | OverHeat | 0x3101 | 5 | Basic Set: When the temperature change value is over or under the threshold set by Param16. Scale is determined by Param64. | 0 | |
4 | UnderHeat | 0x3101 | 5 | Basic Set: When the temperature change value is under or over the threshold set by Param17. Scale is determined by Param64. | 0 | |
5 | OverHumidity | 0x3105 | 5 | Basic Set: When the current humidity is over or under the threshold set by Param14 | 0 | |
6 | UnderHumidity | 0x3105 | 5 | Basic Set: When the current humidity is under or over the threshold set by Param15 | 0 | |
7 | OverLight | 0x3103 | 5 | Basic Set: When the current light/lux is over or under the threshold set by Param18 | 0 | |
8 | UnderLight | 0x3103 | 5 | Basic Set: When the current light/lux is under or over the threshold set by Param19. | 0 | |
9 | OverUV | 0x311B | 5 | Basic Set: When the current UV is over or under the threshold set by Param20 | 0 | |
10 | UnderUV | 0x311B | 5 | Basic Set: When the current UV is under or over the threshold set by Param21 | 0 | |
11 | Temperature | 0x3101 | 5 | Sensor Multilevel Report: When sensors above over limit or below under limit. | 0 |