There are over 4401 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Beaming Enable/Disable | Used to enable/disable beaming. If set to 1, FLiR commands will be supported. But the device must be re-included into the network to activate it. 0 - disable 1 - enable | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable | ||||
1 (2) | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Power Status | This value is Readonly. Used to report the power status (USB or Battery powered) 0 - When battery powered, the device will act as RSS. 1 - When USB cable insert, the device will act as LSS. The device must be re-included in the network to change the role type. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | Yes | No | No |
Bit (Value) |
Description |
||||
0 (1) | When battery powered, the device will act as RSS. | ||||
1 (2) | When USB cable insert, the device will act as LSS. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
101 | 1 | Automatic Report Checklist 1 | Checklist 1 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param111. 1 - Battery 16 - UV 32 - Temperature 64 - Humidity 128 - Lux | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
241 | 0 | 241 | No | No | No |
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
102 | 1 | Automatic Report Checklist 2 | Checklist 2 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param112. 1 - Battery 16 - 32 - Temperature 64 - Humidity 128 - Lux | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 241 | No | No | No |
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
103 | 1 | Automatic Report Checklist 3 | Checklist 3 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param113. 1 - Battery 16 - UV 32 - Temperature 64 - Humidity 128 - Lux | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 241 | No | No | No |
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Motion Group Control(Group2) | Set control of other devices on group2 based on motion trigger. 0 - Send BASIC_SET (0xFF) when motion is triggered to associated device Send BASIC_SET (0x00) when motion is untriggered to associated device 1 - Send BASIC_SET (0x00) when motion is triggered Send BASIC_SET (0xFF) when motion is untriggered 2 - Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered. 3 - Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered. 4 - Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered. 5 - Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered. 6 - Send BASIC_SET (value is configured by parameter 12) when motion is triggered to associated devices. Send BASIC_SET (value is configured by parameter 12) when motion is untriggered. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 6 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Send BASIC_SET (0xFF) when motion is triggered to associated device Send BASIC_SET (0x00) when motion is untriggered to associated device | ||||
1 (2) | Send BASIC_SET (0x00) when motion is triggered Send BASIC_SET (0xFF) when motion is untriggered | ||||
2 (4) | Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered. | ||||
3 (8) | Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered. | ||||
4 (16) | Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered. | ||||
5 (32) | Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered. | ||||
6 (64) | Send BASIC_SET (value is configured by parameter 12) when motion is triggered to associated devices. Send BASIC_SET (value is configured by parameter 12) when motion is untriggered. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
111 | 2 | Automatic Checklist 1 Interval Time | Interval time set in seconds to check the checklist1’s items. Multilevel Sensor Report will be sent when timeout. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3600 | 30 | 65535 | No | No | No |
Value |
Description |
||||
30 | Interval time set in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
112 | 2 | Automatic Checklist 2 Interval Time | Interval time set in seconds to check the checklist2’s items. Multilevel Sensor Report will be sent when timeout. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3600 | 30 | 65535 | No | No | No |
Value |
Description |
||||
30 | Interval time set in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
113 | 2 | Automatic Checklist 3 Interval Time | Interval time set in seconds to check the checklist3’s items. Multilevel Sensor Report will be sent when timeout. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3600 | 30 | 65535 | No | No | No |
Value |
Description |
||||
30 | Interval time set in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 2 | Motion Group Value Setting | Set Basic Set value for Group2. The MSB will act as the basic set value when motion trigger. The LSB will act as the basic set value when motion untrigger. E.g. value=0x0A00, then BASIC_SET(0x0A) will be sent when motion trigger, BASIC_SET(0x00) will be sent when motion untrigger. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
65280 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | Set Basic Set value for Group2. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 2 | Motion Group Control Requirement | Set threshold of Light/Lux when devices associated in group2 should be triggered by motion. Associated device only receive BASIC_SET command when light | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
30000 | 0 | 30000 | No | No | No |
Value |
Description |
||||
0 | Set threshold of Light/Lux | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 1 | Over Humidity Group Threshold (Group5) | Set threshold of humidity. If measured humidity >= (this value), send BASIC_SET (0xFF) to associated devices through group5. If measured humidity < (this value) send BASIC_SET (0x00) to associated devices through group5. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Set threshold of humidity. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | Under Humidity Group Threshold (Group6) | Set threshold of humidity. If measure humidity (this value) send BASIC_SET (0x00) to associated devices through group6. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
40 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Set threshold of humidity. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 2 | Over Heat Group Threshold (Group3) | Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature >= (this value, Scale is determined by Param64) send BASIC_SET (0xFF) to associated devices. If measured temperature<(this value) send BASIC_SET (0x00) to associated devices. E.g. Value 239 means 23.9 C. Value 750 means 75.0 F. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
239 | -400 | 850 | No | No | No |
From |
To |
Description |
|||
-400 | 850 | Set threshold of temperature | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 2 | Under Heat Group Threshold (Group4) | Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature (this value) send BASIC_SET (0x00) to associated devices. E.g. Value 155 means 15.5 C. Value 600 means 60.0 F. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
155 | -400 | 850 | No | No | No |
From |
To |
Description |
|||
-400 | 850 | Set threshold of temperature | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 2 | Over Light Group Threshold (Group7) | Set threshold of Light/Lux. If measured light/lux >= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux < (this value) send BASIC_SET (0x00) to associated devices. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2000 | 0 | 30000 | No | No | No |
Value |
Description |
||||
0 | Set threshold of Light/Lux. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 2 | Under Light Group Threshold (Group8) | Set threshold of Light/Lux. If measured light/lux (this value) send BASIC_SET (0x00) to associated devices. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
100 | 0 | 30000 | No | No | No |
Value |
Description |
||||
0 | Set threshold of Light/Lux. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 2 | Motion Retrigger Time | Presence re-detection time set in second to allow motion sensor to reset timeout of motion sensor. In this time, the motion sensor can not be triggered again. If this value reach zero, the timeout configuration value set by Param3 will be reset. This setting value must always be less than timeout configuration. 0 - disable 1~3600 - timeout set in seconds | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
30 | 30 | 3600 | No | No | No |
Value |
Description |
||||
30 | timeout set in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | Over UV Group Threshold (Group9) | Set threshold of UV. If measured UV >= (this value) send BASIC_SET (0xFF) to associated devices. If measured UV < (this value) send BASIC_SET (0x00) to associated devices. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
8 | 0 | 11 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Set threshold of UV. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
201 | 2 | Temperature Offset Value | Can add or minus this setting value to calibrate temperature when checked. Scale is defined by Param64. e.g. Value 15 means 1.5C or 1.5F. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -200 | 200 | No | No | No |
From |
To |
Description |
|||
-200 | 200 | Temperature Offset Value | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
202 | 1 | Humidity Offset Value | Can add or minus this setting value to calibrate humidity when checked. Unit: %. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -100 | 100 | No | No | No |
From |
To |
Description |
|||
-100 | 100 | Humidity Offset Value | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
203 | 2 | Lux Offset Value | Can add or minus this setting value to calibrate Lux when checked. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -10000 | 10000 | No | No | No |
From |
To |
Description |
|||
-10000 | 10000 | Lux Offset Value | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
204 | 1 | UV Offset Value | Can add or minus this setting value to calibrate UV when checked. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -10 | 10 | No | No | No |
From |
To |
Description |
|||
-10 | 10 | Offset Value range -10-10. | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
21 | 1 | Under UV Group Threshold (Group10) | Set threshold of UV. If measured UV (this value) send BASIC_SET (0x00 to associated devices.) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 11 | No | No | No |
Value |
Description |
||||
0 | Set threshold of UV. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 2 | Motion Untrigger Time | Timeout configuration set in second for motion sensor to send no trigger status. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 30 | 3600 | No | No | No |
Value |
Description |
||||
30 | timeout set in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
39 | 1 | Low Battery Threshold | Configure low battery report threshold, sends low battery report via notification and battery report when battery level drops under setting. Unit %. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 10 | 90 | No | No | No |
Value |
Description |
||||
10 | Configure low battery report threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Motion Sensitivity | Set the sensitivity of motion sensor. 0 - disable 1- minimum sensitivity 11 - maximum sensitivity | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
11 | 0 | 11 | No | No | No |
Value |
Description |
||||
0 | Disable | ||||
1 | sensitivity range | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
40 | 1 | Threshold Check Enable/Disable | Enable/Disable threshold reporting, check time can be adjusted by Param45. 0 - disable all threshold reports 1 - enable all threshold reports | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | disable all threshold reports | ||||
1 (2) | enable all threshold reports | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
41 | 1 | Temperature Threshold | Threshold = (Value * 0.1) Scale is determined by Param64. 0 = disable. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Threshold = (Value * 0.1) Scale is determined by Param64. 0 = disable. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
42 | 1 | Humidity Threshold | Humidity range = 1% to 50%, 0 = disable. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 50 | No | No | No |
Value |
Description |
||||
0 | Humidity range = 1% to 50%, 0 = disable. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
43 | 2 | Lux Threshold | 0 = disable | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
250 | 0 | 10000 | No | No | No |
Value |
Description |
||||
0 | Lux Threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
44 | 1 | UV Threshold | 0 = disable | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 11 | No | No | No |
Value |
Description |
||||
0 | UV Threshold | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
45 | 2 | Threshold Check Time | Set threshold check time in seconds if threshold is enable via Param40. 1~65535 - When USB powered 60~65535 - When Battery powered | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 1 | 65535 | No | No | No |
Value |
Description |
||||
1 | Set threshold check time in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
46 | 1 | Low Temperature Report | Eable/Disable alarm report for low temperature( | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable | ||||
1 (2) | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
48 | 1 | Sensor Limit Control | This value is bit mask. Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value. 1 - Temperature upper level 2 - Humidity upper level 4 - Lux upper level 8 - UV upper level 16 - Temperature lower level 32 - Humidity lower level 64 - Lux lower level 128 - UV lower level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
49 | 2 | Temperature Upper Limit | Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current measurement) > (Upper Limit), then report sensor. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
280 | -400 | 1000 | No | No | No |
From |
To |
Description |
|||
-400 | 1000 | Set upper limit level for temperature | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Motion Report Type | Set which command class will be sent when motion sensor is triggered or detriggered. 0 - Sends Notification Report 1 - Sends Sensor Binary Report 2 - Sends Notification and Sensor Binary Report | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Sends Notification Report | ||||
1 (2) | Sends Sensor Binary Report | ||||
2 (4) | Sends Notification and Sensor Binary Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
50 | 2 | Temperature Lower Limit | Set lower limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current Measurement) < (Lower limit), then report sensor. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -400 | 1000 | No | No | No |
From |
To |
Description |
|||
-400 | 1000 | Set lower limit level for temperature | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
51 | 1 | Temperature Recover Limit | Temperature recover limit set in scale of 0.1. Scale is determined by Param64. If (Current measurement) = (lower limit + recover limit), then temperature report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 1 | 255 | No | No | No |
Value |
Description |
||||
1 | Temperature recover limit set in scale of 0.1. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
52 | 1 | Humidity Upper Limit | Set humidity upper limit level. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Set humidity upper limit level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
53 | 1 | Humidity Lower Limit | Set humidity lower limit level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
40 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Set humidity lower limit level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
54 | 1 | Humidity Recover Limit | Set humidity recover limit level. Refer to Param 51. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 50 | No | No | No |
Value |
Description |
||||
1 | Set humidity recover limit level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
55 | 2 | Lux Upper Limit | Set lux upper limit level. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1000 | 0 | 30000 | No | No | No |
Value |
Description |
||||
0 | Set lux upper limit level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
56 | 2 | Lux Lower Limit | Set lux lower limit level. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
100 | 0 | 30000 | No | No | No |
Value |
Description |
||||
0 | Set lux lower limit level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
58 | 1 | UV Upper Limit | Set UV upper limit level. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
8 | 1 | 11 | No | No | No |
Value |
Description |
||||
1 | Set UV upper limit level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
59 | 1 | UV Lower Limit | Set UV lower limit level. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
4 | 1 | 11 | No | No | No |
Value |
Description |
||||
1 | Set UV lower limit level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Vibration Sensor Enable/Disable | Used to enable/disable vibration sensor. 0 - disable vibration 1~254 - timeout set in minutes to reset vibration status 255 - timeout set in minutes to reset vibration status | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | disable vibration | ||||
1 | timeout set in minutes to reset vibration status | ||||
255 | timeout set in minutes to reset vibration status | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
60 | 1 | UV Recover Limit | Set UV recover limit level. Refer to Param 51. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 5 | No | No | No |
Value |
Description |
||||
1 | Set UV recover limit level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
61 | 1 | Out-of-limit State | This is read only and bit mask. Out of the limit state of sensors. Bit Mask: 0 - within limit 1 - out of limit Value: 1 - Temperature upper level 2 - Humidity upper level 4 - Lux upper level 8 - UV upper level 16 - Temperature lower level 32 - Humidity lower level 64 - Lux lower level 128 - UV lower level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | Yes | No | No |
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
64 | 1 | Temperature Scale | Set the scale for temperature when reports. 0 - Celsius 1 - Fahrenheit | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Celsius | ||||
1 (2) | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
67 | 1 | Lux Recover Limit | Set lux recover limit level. Refer to Param 51. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
100 | 1 | 255 | No | No | No |
Value |
Description |
||||
1 | Set lux recover limit level. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Vibration Intensity Reports | Used to enable/disable vibration intensity reports. If set to 1, vibration intensity will be sent to gateway when triggered. If set to 0, do not report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable | ||||
1 (2) | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
81 | 1 | LED Activity | Allow user to enable/disable LED activity of specific reports sent by sensor. Button press indicator is not affected by this. 0 - disable 1 - enable | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | disable | ||||
1 (2) | enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
82 | 1 | Motion Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of motion sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable | ||||
1 (2) | Red | ||||
2 (4) | Blue | ||||
3 (8) | Green | ||||
4 (16) | Pink | ||||
5 (32) | Cyan | ||||
9 (512) | White | ||||
6 (64) | Purple | ||||
7 (128) | Orange | ||||
8 (256) | Yellow | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
83 | 1 | Temperature Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of temperature sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable. Other value descriptions, please see above description box of this parameter. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
84 | 1 | Humidity Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of humidity sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable. Other value descriptions, please see above description box of this parameter. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
85 | 1 | Lux Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of Lux sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable. Other value descriptions, please see above description box of this parameter. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
86 | 1 | UV Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of UV sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable. Other value descriptions, please see above description box of this parameter. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
87 | 1 | Vibration Sensor Report Indicator | If LED is enabled by Param81, allow user to change the report color of vibration sensor. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable. Other value descriptions, please see above description box of this parameter. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
88 | 1 | Battery Report Indicator | If LED is enabled by Param81, allow user to change the report color of battery. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable. Other value descriptions, please see above description box of this parameter. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
89 | 1 | Wakeup Report Indicator | If LED is enabled by Param81, allow user to change the report color of wakeup. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
8 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable. Other value descriptions, please see above description box of this parameter. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Wakeup CC Timeout | Timeout set in seconds after Wakeup CC is send out before go to sleep. If wakeup no more information received, return to sleep mode immediately. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
15 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Timeout set in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
90 | 1 | Communication Indicator | If LED is enabled by Param81, allow user to change indicator color when receiving communication from gateway or other devices. 0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 9 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Disable. Other value descriptions, please see above description box of this parameter. | ||||