Z-Wave Products

There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Heatit ZM Single Relay 16A (ZM Single Relay 16A)

Z-Wave Certification Number: ZC12-21010159


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Load limit Ensures that the device does not draw more current than rated. Immunity for power consumption peaks.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

16 1 16 No No No

Value

 

Description

1   1-16 ampere. Default is 16 (16 ampere)

Parameter Number

Parameter Size

Parameter Name

Description

10 2 Meter report interval Time interval between consecutive meter reports. Meter reports can also be sent as a result of polling.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

900 30 32767 No No No

Value

 

Description

30   30 seconds – 32767 seconds.

Parameter Number

Parameter Size

Parameter Name

Description

11 2 Meter report delta value Meter report delta value

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

75 5 3600 No No No

Value

 

Description

5   5-3600W.

Parameter Number

Parameter Size

Parameter Name

Description

2 2 Power shutdown actions Decide how the device should react when the overload/overheating features has turned relay OFF

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 0 32767 No No No

Value

 

Description

0   Disabled and will not retry. User needs to manually turn on afterwards. If temperature overload is on, device will not turn on until device has cooled down.
1   After power shut down (param 1) device will try to turn back ON after delay specified here. (Time in minutes)

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Switch Type Decides what type of switch is connected.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Momentary Switch
1   Toggle Switch

Parameter Number

Parameter Size

Parameter Name

Description

4 1 S1/Button operation S1/Button operation

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Button turns load on/off and sends Meter report + Relay status.
1   Button sends Meter report + Relay status, load can be only controlled wirelessly

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Scene notifications Decides if/what scene controller notifications the device sends to gateway.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   Sends scene controller for S2. S1 disabled
1   Sends scene controller for S1. S2 disabled
2   Sends scene controller for S1 and S2
3   Scene controller deactivated.

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Restore Power Level Relay power level after power is restored from power-outage. When device is from factory/factory reset the first state of the device should be OFF

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   Always OFF on restored power
1   Always ON on restored power
2   Restore last state on restored power (Default)

Parameter Number

Parameter Size

Parameter Name

Description

7 4 Automatic Turn off Time to turn relay OFF after having been turned ON

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 86400 No No No

Value

 

Description

0   Auto OFF disabled.
1   Auto OFF timeout in seconds

Parameter Number

Parameter Size

Parameter Name

Description

8 4 Automatic Turn on Time to turn relay ON after having been turned OFF

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 86400 No No No

Value

 

Description

0   Auto ON disabled.
1   Auto ON timeout in seconds

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Inverted Output Decides if the relay output should be inverted

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   Standard operation
1   Inverted Output