Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Load limit | Ensures that the device does not draw more current than rated. Immunity for power consumption peaks. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
16 | 1 | 16 | No | No | No |
Value |
Description |
||||
1 | 1-16 ampere. Default is 16 (16 ampere) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 2 | Meter report interval | Time interval between consecutive meter reports. Meter reports can also be sent as a result of polling. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
900 | 30 | 32767 | No | No | No |
Value |
Description |
||||
30 | 30 seconds – 32767 seconds. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 2 | Meter report delta value | Meter report delta value | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
75 | 5 | 3600 | No | No | No |
Value |
Description |
||||
5 | 5-3600W. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 2 | Power shutdown actions | Decide how the device should react when the overload/overheating features has turned relay OFF | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 0 | 32767 | No | No | No |
Value |
Description |
||||
0 | Disabled and will not retry. User needs to manually turn on afterwards. If temperature overload is on, device will not turn on until device has cooled down. | ||||
1 | After power shut down (param 1) device will try to turn back ON after delay specified here. (Time in minutes) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Switch Type | Decides what type of switch is connected. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Momentary Switch | ||||
1 | Toggle Switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | S1/Button operation | S1/Button operation | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Button turns load on/off and sends Meter report + Relay status. | ||||
1 | Button sends Meter report + Relay status, load can be only controlled wirelessly | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Scene notifications | Decides if/what scene controller notifications the device sends to gateway. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | Sends scene controller for S2. S1 disabled | ||||
1 | Sends scene controller for S1. S2 disabled | ||||
2 | Sends scene controller for S1 and S2 | ||||
3 | Scene controller deactivated. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Restore Power Level | Relay power level after power is restored from power-outage. When device is from factory/factory reset the first state of the device should be OFF | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Always OFF on restored power | ||||
1 | Always ON on restored power | ||||
2 | Restore last state on restored power (Default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 4 | Automatic Turn off | Time to turn relay OFF after having been turned ON | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 86400 | No | No | No |
Value |
Description |
||||
0 | Auto OFF disabled. | ||||
1 | Auto OFF timeout in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 4 | Automatic Turn on | Time to turn relay ON after having been turned OFF | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 86400 | No | No | No |
Value |
Description |
||||
0 | Auto ON disabled. | ||||
1 | Auto ON timeout in seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Inverted Output | Decides if the relay output should be inverted | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Standard operation | ||||
1 | Inverted Output | ||||