There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Leakage/Moisture alarm | Turn the Leakage Alarm to On or Off | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Leakage/Moisture alarm level | Set the trigger level at which the Leakage Alarm Notification Report will be sent | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 1 | 100 | No | No | No |
From |
To |
Description |
|||
1 | 100 | (1: Almost Dry, 100: Wet) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 1 | Leakage/Moisture reporting period | Select the number of hours between moisture reports. Report values between -100 to 100 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 120 | No | No | No |
From |
To |
Description |
|||
0 | 120 | Hours (Hours between reports). Default: 0 = Off | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | Activate supervision | Activate Supervision command for only important alarm events or all events. *Supervised commands require a confirmation from the gateway when a notification is received | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | Alarm Report (*Only for alarm events e.g. Leakage alarm) | ||||
2 (4) | All Reports | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | LED alarm event reporting | Turn On or Off LED for specific event indications (ex. alarms). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | Wake-Up moisture polling workaround for Fibaro G | Turn On or Off Moisture reporting during polling (applicable only for Fibaro gateway users) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | Yes |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
23 | 1 | Perform leakage/moisture sensor calibration | Should be performed when Drip is mounted correctly and absolutely dry to calibrate the \"zero-level\". A Multilevel Sensor Report with the Moisture value is sent after calibration is performed | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Device resets to this value after performing capacitance calibration and sends a report with value 0 to the gateway (as recommended by Z-Wave Specifications.) | ||||
1 (2) | Perform Calibration | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
24 | 1 | Temperature offset | The offset value is used to calibrate temperature reports in the actual temperature. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -100 | 100 | No | No | No |
From |
To |
Description |
|||
-100 | 100 | [=-10.0 to +10.0 (Degree C)] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
25 | 2 | Temperature reporting period | Select the number of minutes between the temperature reports (15 minutes to 24 hours) (used for parameter 4) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1440 | 15 | 1440 | No | No | No |
Value |
Description |
||||
15 | (minutes between reports) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
26 | 1 | Temperature Delta | A new temperature report is sent when the temperature has changed more than the delta value. Input value converted to one decimal place | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 5 | 100 | No | No | No |
Value |
Description |
||||
5 | [=0.5 to 10.0 (Degree C)], Default: 20 (= 2.0 Degree C) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
27 | 1 | Temperature hysteresis for temperature alarms | Triggers alarm clear reports (see parameters 7 & 8). Input value converted to one decimal place | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 5 | 100 | No | No | Yes |
Value |
Description |
||||
5 | [=0.5 to 10.0 (Degree C)], Default: 20 (= 2.0 Degree C) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Temperature reporting type | Turn On or Off temperature sensor value reporting (does not affect temperature alarms) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On. Reports the actual value when the temperature is changed according to parameter 26 since the last report or at least according to the reporting period set in the config parameter 25. | ||||
2 (4) | On. Reports the actual value periodically based on the config parameter 25. | ||||
3 (8) | On. The average temperature during the period is sent periodically during every wake up interval. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Temperature reporting unit | Select the temperature unit | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Celsius | ||||
1 (2) | Fahrenheit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Temperature alarms | Turn On or Off the temperature alarm | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Bit (Value) |
Description |
||||
0 (1) | Off | ||||
1 (2) | On | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | High temperature alarm level | Select a high temperature alarm level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
40 | -20 | 80 | No | No | No |
From |
To |
Description |
|||
-20 | 80 | (Degree C) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Low temperature alarm level | Select a low temperature alarm level | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | -20 | 60 | No | No | No |
From |
To |
Description |
|||
-20 | 60 | (Degree C) | |||