Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Parameter no. 1 – Relay contact type | 0 (Default) |
NO (normally open) output type | |
1 | NC (normally close) output type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Parameter no. 10. – auto on timer | 0 (Default) |
disabled | |
30 to 32525 | 30 – 32535 seconds after which the device turns on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Parameter no. 11. – auto off timer | 0 | disabled | |
30 to 32525 (Default) |
30 – 32535 seconds after which the device turns off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Parameter no. 12. – auto on timer relay | 0 | disabled | |
30 to 32525 (Default) |
30 – 32535 seconds after which the device turns on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | Parameter no. 13. – auto off timer relay | 0 | disabled | |
30 to 32525 (Default) |
30 – 32535 seconds after which the device turns off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Parameter no 3. – turning off alarming | 0 | only by z-wave command (basic set, switch multilevel set, switch multilevel start/stop level change, switch color set, switch color start/stop level change, notification report idle) | |
1 (Default) |
capacitive input (up, down, left, right) or z-wave command (basic set, switch multilevel set, switch multilevel start/stop level change, , switch color set, switch color start/stop level change, notification report idle) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Parameter no. 30. – restore state on power failure | 1 (Default) |
enabled (the device will restore state on power failure) | |
0 | disabled (the device will not restore state on power failure and will remain off) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 1 | Parameter no. 31. – restore relay state on power failure | 1 (Default) |
enabled (the device will restore state on power failure) | |
0 | disabled (the device will not restore state on power failure and will remain off) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 2 | Parameter no. 40 – Watt Power Consumption Reporting Threshold for Load | 0 | Power consumption reporting disabled | |
1 to 100 (Default) |
= 1 % - 100 % Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1 % (the lowest value possible). NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported, REGARDLESS of percentage set in this parameter. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | Parameter no. 42 – Watt Power Consumption Reporting Time Threshold for Load | 0 (Default) |
Power consumption reporting disabled | |
30 to 32525 | 30 - 32535 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Parameter no. 60 – Lock touch for relay only | 0 (Default) |
disabled | |
1 | enabled (the user can switch ON/OFF the connected light or any other connected load by touching ANY button. Other functionalities (lighting mode, scenes, dimming and full white, inclusion/exclusion and reset) are unavailable until function disabled). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
70 | 2 | Parameter no. 70 - Overload safety switch | 0 | function not active | |
1 to 2300 (Default) |
1 W – 2300 W | ||||