There are over 4242 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Association Capabilities

Model: MultiSensor 7 (ZWA024-A)

Z-Wave Certification Number: ZC12-21080291


Group ID Group Profile Name Profile Maximum Nodes Description Endpoint ID Commands
1 Lifeline 0x0001 5 Lifeline. Device Reset Locally: When factory reset. Notification Report: See Notification Chapter for more information. Sensor Binary Report: See Param5 for more information. Sensor Multilevel Report: When sensors above over limit or below under limit. Battery Report: See Param101. Indicator Report: Issued when the indicator light changed 0
2 Motion 0x7107 5 Basic Set Command will be sent to the associated device when motion trigger or untrigger. The basic set value is determined by Param11, Param12. See Param13 for more information. 0
3 OverHeat 0x3101 5 Basic Set: When the temperature change value is over or under the threshold set by Param16. Scale is determined by Param64. 0
4 UnderHeat 0x3101 5 Basic Set: When the temperature change value is under or over the threshold set by Param17. Scale is determined by Param64. 0
5 OverHumidity 0x3105 5 Basic Set: When the current humidity is over or under the threshold set by Param14 0
6 UnderHumidity 0x3105 5 Basic Set: When the current humidity is under or over the threshold set by Param15 0
7 OverLight 0x3103 5 Basic Set: When the current light/lux is over or under the threshold set by Param18 0
8 UnderLight 0x3103 5 Basic Set: When the current light/lux is under or over the threshold set by Param19. 0
9 OverUV 0x311B 5 Basic Set: When the current UV is over or under the threshold set by Param20 0
10 UnderUV 0x311B 5 Basic Set: When the current UV is under or over the threshold set by Param21 0
11 Temperature 0x3101 5 Sensor Multilevel Report: When sensors above over limit or below under limit. 0