TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Volume | Set Volume Level to high (1), low (2), or silent (3). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 1 | 3 | No | No | No |
From |
To |
Description |
|||
1 | 3 | Volume | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | One Touch Locking | Set One Touch Locking feature to enable or disable. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
255 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | One Touch Locking | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Privacy Button | Set Privacy Button feature to enable or disable. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Privacy Button | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Lock Status LED | Set Lock Status LED feature to enable or disable. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Lock Status LED | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Auto Relock | Set Auto Relock feature to enable or disable. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 255 | No | No | No |
Value |
Description |
||||
0 | Auto Relock | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Relock Time | Adjust the time your lock will auto relock. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
30 | 0 | 127 | No | No | No |
From |
To |
Description |
|||
0 | 127 | Relock Time | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Wrong Code Entry Limit | Adjust the limit for wrong code entries allowed by your lock. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 0 | 5 | No | No | No |
From |
To |
Description |
|||
0 | 5 | Wrong Code Entry Limit | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Language | Set the language to English (1), Spanish (2), or French (3). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 3 | No | No | No |
From |
To |
Description |
|||
1 | 3 | Language | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Shut Down Time | Adjust the time your lock is shutdown after reaching its wrong code entry limit. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 0 | 127 | No | No | No |
From |
To |
Description |
|||
0 | 127 | Shut Down Time | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Operating Mode | Set the Operating Mode to normal mode(0), vacation mode(1) or privacy mode(2). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
From |
To |
Description |
|||
0 | 2 | Operating Mode | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Reset to Factory Resets | Lock will execute Reset To Factory when parameter is set. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 1 | No | No | No |
From |
To |
Description |
|||
1 | 1 | Reset to Factory Resets | |||