Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: ON/OFF SWITCH 700 (ZEN71)

Z-Wave Certification Number: ZC12-21020181


Parameter Number

Parameter Size

Parameter Name

Description

1 1 On/Off Paddle Orientation Choose if you want the upper paddle to turn the light on or turn the light off when tapped.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   Upper paddle turns the light on, lower paddle turns it off (default)
1   Upper paddle turns the light off, lower paddle turns it on
2   Any paddle turns light on/off

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Smart Bulb Mode: Enable/Disable Paddle / Z-Wave Control Enable or disable local on/off control. If enabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   physical paddle control disabled
1   physical paddle control enabled (default)
2   physical paddle and Z-Wave control disabled

Parameter Number

Parameter Size

Parameter Name

Description

12 1 3-Way Switch Type Choose the type of 3-way switch you want to use with this switch in a 3-way set-up.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   regular mechanical 3-way on/off switch, use the connected 3-way switch to turn the light on or off (default)
1   momentary switch, click once to change status (light on or off)

Parameter Number

Parameter Size

Parameter Name

Description

13 1 Smart Bulb Mode Behavior Set reporting behavior for disabled physical control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   switch reports on/off status and change LED indicator state even if physical and Z-Wave control is disabled (default)
1   switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled.

Parameter Number

Parameter Size

Parameter Name

Description

14 1 LED Indicator Color Choose the color of the LED indicator.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

Value

 

Description

0   white
1   blue
2   green
3   red

Parameter Number

Parameter Size

Parameter Name

Description

15 1 LED Indicator Brightness Choose the LED indicator's brightness level.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   bright (100%)
1   medium (60%)
2   low (30%)

Parameter Number

Parameter Size

Parameter Name

Description

16 1 Association Reports Choose how the switch reports its status back to the hub.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   Binary switch report for Z-Wave control, basic set report for paddle control
1   binary switch report for both Z-Wave and paddle control (default)

Parameter Number

Parameter Size

Parameter Name

Description

2 1 LED Indicator Control Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   LED indicator is on when switch is off, LED indicator is off when switch is on (default)
1   LED indicator is on when switch is on, LED indicator is off when switch is off
2   LED indicator is always OFF
3   LED indicator is always ON.

Parameter Number

Parameter Size

Parameter Name

Description

3 4 Auto Turn-Off Timer Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   timer disabled (default);
1   minutes

Parameter Number

Parameter Size

Parameter Name

Description

5 4 Auto Turn-On Timer Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   timer disabled
1   minutes

Parameter Number

Parameter Size

Parameter Name

Description

8 1 On Off Status After Power Failure Set the on off status for the switch after power failure.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   forced to OFF (regardless of state prior to power outage)
1   forced to ON (regardless of state prior to power outage)
2   remembers and restores on/off status after power failure (default)

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Enable/Disable Scene Control Enable or disable scene control functionality for quick double tap triggers.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   scene control disabled (default)
1   scene control enabled