There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Z-Wave Secondary Keypad (M/N: KP01)

Z-Wave Certification Number: ZC12-21030206


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Motion Detector Whether or not motion detector is enabled. 1: Enabled (default) / 0: Disabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

1 (2)   Enabling motion detector
0 (1)   disable motion detector

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Sound Enable beeper feedback. 1: Enabled (default) / 0: Disabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

1 (2)   enable sound/buzzer
0 (1)   disable sound/buzzer

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Down-Cast Light Enable the down-cast light. 1: Enabled (default) / 0: Disabled.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Bit (Value)

 

Description

1 (2)   enable down-cast lighting
0 (1)   disable down-cast lighting

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Application-Level Retries Number of attempts on top of the stack-level retries to try to reach the controller/hub with Z-Wave messages.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 10 No No Yes

Value

 

Description

0   how many retries device does to reach controller/hub

Parameter Number

Parameter Size

Parameter Name

Description

5 2 Battery-Poll Timer Amount of time in minutes between timed battery checks.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

70 5 1440 No No Yes

Value

 

Description

5   the amount of time in minute between timed battery checks.