Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart On/Off Switch (MS10ZS)

Z-Wave Certification Number: ZC12-21040212


Parameter Number

Parameter Size

Parameter Name

Description

1 1 KeyFunction Parameter=1,Size=1, Value=0 Up Button: On Down Button: Off Value=1 Up Button: Off Down Button: On Value=2 Up Button: On/Off Down Button: On/Off

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   Up Button ON,Down Button OFF
1   Up Button OFF,Down Button ON
2   Up Button ON/OFF,Down Button ON/OFF

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Enable or Disable OutPut control Parameter=11,Size=1,Value=0 disable local button and External Switch control enable Z-Wave control Value=1 enable local button and External Switch control enable Z-Wave control Value = 2 disable local button and External Switch control

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   disable local button and External Switch control
1   enable local button and External Switch control enable Z-Wave control
2   disable local button and External Switch control

Parameter Number

Parameter Size

Parameter Name

Description

12 1 external switch type Parameter=12, Size=1, Value=0 toggle switch(device changes status when switch changes status)(default); Value=1 momentary switch

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   toggle switch (device changes status when switch changes status)
1   momentary switch

Parameter Number

Parameter Size

Parameter Name

Description

13 1 Behavior when Output control disabled Parameter 13 Size=1,Value=0 report on/off status and change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). Value=1 DON’t report on/off status or change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). Default = 0

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   report on/off status and change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled)
1   DON’t report on/off status or change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).

Parameter Number

Parameter Size

Parameter Name

Description

14 1 LED Indicator Color Parameter=14,Size=1, Value=0 White Value=1 Blue Value=2 Green Value=3 Red

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

Value

 

Description

0   White
1   Blue
2   Green
3   Red

Parameter Number

Parameter Size

Parameter Name

Description

15 1 LED Indicator Brightness Parameter=15,Size=1, Value=0 Bright (100%) Value=1 Medium (60%) Value=2 Low (30%)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   Bright (100%)
1   Medium (60%)
2   Low (30%)

Parameter Number

Parameter Size

Parameter Name

Description

16 1 Association reports Parameter=16,Size=1 Values: 0 – Z-Wave control:Binary switch report Manual control: Basic set report 1 – Z-Wave control:Binary switch report Manual control:  Binary switch report

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   Z-Wave control:Binary switch report Manual control: Basic set report
1   Z-Wave control:Binary switch report Manual control:  Binary switch report

Parameter Number

Parameter Size

Parameter Name

Description

2 1 LED Indicator Parameter=2,Size=1 Value=0 On when Off and Off when On Value=1 On when On and Off when Off Value=2 Always Off Value=3 Always On

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   On when Off and Off when On
1   On when On and Off when Off
2   Always OFF
3   Always ON

Parameter Number

Parameter Size

Parameter Name

Description

3 4 Auto Turn-Off Timer Parameter=3,Size=4, Value=0 timer disabled (default);  Values: 1 – 65535 (minutes); 

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   timer disabled
1   Auto Turn-Off Timer

Parameter Number

Parameter Size

Parameter Name

Description

5 4 Auto Turn-On Timer Parameter=5,Size=1, Value=0 timer disabled (default);  Values: 1 – 65535 (minutes); 

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   timer disabled
1   timer disabled

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Restores state after power failure Parameter=8,Size=1, Value=0 output off Value=1 output on Value=2 out put the state after power

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   output off
1   Output ON
2   out put the state after power

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Enable or Disable Scene Parameter=9,Size=1, Value=0 disable Value=1 enable

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   disable
1   enable