Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | KeyFunction | Parameter=1,Size=1, Value=0 Up Button: On Down Button: Off Value=1 Up Button: Off Down Button: On Value=2 Up Button: On/Off Down Button: On/Off | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Up Button ON,Down Button OFF | ||||
1 | Up Button OFF,Down Button ON | ||||
2 | Up Button ON/OFF,Down Button ON/OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Enable or Disable OutPut control | Parameter=11,Size=1,Value=0 disable local button and External Switch control enable Z-Wave control Value=1 enable local button and External Switch control enable Z-Wave control Value = 2 disable local button and External Switch control | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | disable local button and External Switch control | ||||
1 | enable local button and External Switch control enable Z-Wave control | ||||
2 | disable local button and External Switch control | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | external switch type | Parameter=12, Size=1, Value=0 toggle switch(device changes status when switch changes status)(default); Value=1 momentary switch | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | toggle switch (device changes status when switch changes status) | ||||
1 | momentary switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Behavior when Output control disabled | Parameter 13 Size=1,Value=0 report on/off status and change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). Value=1 DON’t report on/off status or change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). Default = 0 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | report on/off status and change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled) | ||||
1 | DON’t report on/off status or change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 1 | LED Indicator Color | Parameter=14,Size=1, Value=0 White Value=1 Blue Value=2 Green Value=3 Red | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | White | ||||
1 | Blue | ||||
2 | Green | ||||
3 | Red | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | LED Indicator Brightness | Parameter=15,Size=1, Value=0 Bright (100%) Value=1 Medium (60%) Value=2 Low (30%) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Bright (100%) | ||||
1 | Medium (60%) | ||||
2 | Low (30%) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | Association reports | Parameter=16,Size=1 Values: 0 – Z-Wave control:Binary switch report Manual control: Basic set report 1 – Z-Wave control:Binary switch report Manual control: Binary switch report | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Z-Wave control:Binary switch report Manual control: Basic set report | ||||
1 | Z-Wave control:Binary switch report Manual control: Binary switch report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | LED Indicator | Parameter=2,Size=1 Value=0 On when Off and Off when On Value=1 On when On and Off when Off Value=2 Always Off Value=3 Always On | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | On when Off and Off when On | ||||
1 | On when On and Off when Off | ||||
2 | Always OFF | ||||
3 | Always ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 4 | Auto Turn-Off Timer | Parameter=3,Size=4, Value=0 timer disabled (default); Values: 1 – 65535 (minutes); | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | timer disabled | ||||
1 | Auto Turn-Off Timer | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 4 | Auto Turn-On Timer | Parameter=5,Size=1, Value=0 timer disabled (default); Values: 1 – 65535 (minutes); | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | timer disabled | ||||
1 | timer disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Restores state after power failure | Parameter=8,Size=1, Value=0 output off Value=1 output on Value=2 out put the state after power | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | output off | ||||
1 | Output ON | ||||
2 | out put the state after power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Enable or Disable Scene | Parameter=9,Size=1, Value=0 disable Value=1 enable | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | disable | ||||
1 | enable | ||||