Z-Wave Products

There are over 4064 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Scenes Controller (ZEN32)

Z-Wave Certification Number: ZC12-21030205


Parameter Number

Parameter Size

Parameter Name

Description

1 1 LED Indicator mode for relay Choose if you want the LED indicator to turn on when the relay is on or off, or if you want it to remain on or off at all times.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   LED on when relay off, LED off when relay on (default)
1   LED on when relay on, LED off when relay off
2   LED always off
3   LED always on

Parameter Number

Parameter Size

Parameter Name

Description

10 1 LED Indicator color for Button 4 Choose the color of the LED indicator for Button 4.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   white
1   blue
2   green
3   red

Parameter Number

Parameter Size

Parameter Name

Description

11 1 LED Indicator brightness for relay Choose the LED indicator's brightness level for the relay.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Bit (Value)

 

Description

0 (1)   white
1 (2)   medium (60%)
2 (4)   low (30%)

Parameter Number

Parameter Size

Parameter Name

Description

12 1 LED Indicator brightness for Button 1 Choose the LED indicator's brightness level for Button 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   bright (100%)
1   medium (60%)
2   low (30%)

Parameter Number

Parameter Size

Parameter Name

Description

13 1 LED Indicator brightness for Button 2 Choose the LED indicator's brightness level for Button 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   bright (100%)
1   medium (60%)
2   low (30%)

Parameter Number

Parameter Size

Parameter Name

Description

14 1 LED Indicator brightness for Button 3 Choose the LED indicator's brightness level for Button 3.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   bright (100%)
1   medium (60%)
2   low (30%)

Parameter Number

Parameter Size

Parameter Name

Description

15 1 LED Indicator brightness for Button 4 Choose the LED indicator's brightness level for Button 4.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   bright (100%)
1   medium (60%)
2   low (30%)

Parameter Number

Parameter Size

Parameter Name

Description

16 4 Auto Turn-Off Timer for Relay Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   disabled
1   minutes

Parameter Number

Parameter Size

Parameter Name

Description

17 4 Auto Turn-ON Timer for Relay Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   disabled
1   minutes

Parameter Number

Parameter Size

Parameter Name

Description

18 1 State After Power Failure Set the on off status for the switch after power failure.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   remembers and restores on/off status after power failure (default)
1   Relay and buttons forced to off after power failure
2   Relay and buttons forced to on after power failure

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Disable / Enable Control on the Relay Enable or disable paddle on/off control (aka disable the relay). If disabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through buttons.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   Disable local / physical control (from the button), enable Z-Wave control
1   1 – Enable local / physical control (from the button), enable Z-Wave control (default)
2   Disable local / physical control (from the button), disable Z-Wave control

Parameter Number

Parameter Size

Parameter Name

Description

2 1 LED Indicator mode for Button 1 Choose if you want the LED indicator to turn on when Button 1 is on or off, or if you want it to remain on or off at all times.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   LED on when dimmer off, LED off when dimmer on (default)
1   LED on when dimmer on, LED off when dimmer off
2   LED always off
3   LED always on

Parameter Number

Parameter Size

Parameter Name

Description

20 1 Relay Behavior with Disabled Local / Z-Wave Control Set reporting behavior for disabled physical control.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   report on/off status when button is pressed and change LED indicator status if Parameter 19 is set to value 0 or 2
1   DON’T report on/off status when button is pressed and DON’T change LED indicator status if Parameter 19 is set to value 0 or 2 (but the relay will always send central scene command)

Parameter Number

Parameter Size

Parameter Name

Description

3 1 LED Indicator mode for Button 2 Choose if you want the LED indicator to turn on when Button 2 is on or off, or if you want it to remain on or off at all times.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   LED on when dimmer off, LED off when dimmer on (default)
1   LED on when dimmer on, LED off when dimmer off
2   LED always off
3   LED always on

Parameter Number

Parameter Size

Parameter Name

Description

4 1 LED Indicator mode for Button 3 Choose if you want the LED indicator to turn on when Button 3 is on or off, or if you want it to remain on or off at all times.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   LED on when dimmer off, LED off when dimmer on (default)
1   LED on when dimmer on, LED off when dimmer off
2   LED always off
3   LED always on

Parameter Number

Parameter Size

Parameter Name

Description

5 1 LED Indicator mode for Button 4 Choose if you want the LED indicator to turn on when Button 4 is on or off, or if you want it to remain on or off at all times.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   LED on when dimmer off, LED off when dimmer on (default)
1   LED on when dimmer on, LED off when dimmer off
2   LED always off
3   LED always on

Parameter Number

Parameter Size

Parameter Name

Description

6 1 LED Indicator color for relay Choose the color of the LED indicator for the relay.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   white
1   blue
2   green
3   red

Parameter Number

Parameter Size

Parameter Name

Description

7 1 LED Indicator color for Button 1 Choose the color of the LED indicator for Button 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   white
1   blue
2   green
3   red

Parameter Number

Parameter Size

Parameter Name

Description

8 1 LED Indicator color for Button 2 Choose the color of the LED indicator for Button 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   white
1   blue
2   green
3   red

Parameter Number

Parameter Size

Parameter Name

Description

9 1 LED Indicator color for Button 3 Choose the color of the LED indicator for Button 3.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   white
1   blue
2   green
3   red