TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: UNIVERSAL RELAY (ZEN17)

Z-Wave Certification Number: ZC12-21030204


Parameter Number

Parameter Size

Parameter Name

Description

1 1 On Off Status After Power Failure Set the on off status for the relays after power failure.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 4 No No No

Value

 

Description

0   ALL relays forced to OFF (regardless of state prior to power outage)
1   ALL relays remember and restore on/off status after power failure (default)
2   ALL relays forced to ON (regardless of state prior to power outage)
3   Relay 1 remembers and restores on/off status after power failure, Relay 2 forced to ON
4   Relay 2 remembers and restores on/off status after power failure, Relay 1 forced to ON.

Parameter Number

Parameter Size

Parameter Name

Description

10 1 Input Trigger for Relay 1 Choose if you’d like the connected input (switch) on S1 C / VC C to trigger the load connected to R1 or if you want to use the input reports for monitoring only and separate the output from the input.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   input trigger disabled
1   input trigger enabled (default)

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Input Trigger for Relay 2 Choose if you’d like the connected input (switch) on S2 C / VC C to trigger the load connected to R2 or if you want to use the input reports for monitoring only and separate the output from the input.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

Value

 

Description

0   input trigger disabled
1   input trigger enabled (default)

Parameter Number

Parameter Size

Parameter Name

Description

15 1 Auto Turn-Off Timer Unit for Relay 1 Choose between seconds, minutes, and hours as the unit for the auto turnoff timer for Relay 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   minutes
1   seconds
2   hours

Parameter Number

Parameter Size

Parameter Name

Description

16 1 Auto Turn-On Timer Unit for Relay 1 Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   minutes
1   seconds
2   hours

Parameter Number

Parameter Size

Parameter Name

Description

17 1 Auto Turn-Off Timer Unit for Relay 2 Choose between seconds, minutes, and hours as the unit for the auto turn off timer for Relay 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   minutes
1   seconds
2   hours

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Auto Turn-On Timer Unit for Relay 2 Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   minutes
1   seconds
2   hours

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Input Type for Relay 1 (S1) Choose the wall switch or input type you want to connect to the S1 C terminals. Press and hold the Z-Wave button for 5 seconds to change to garage mode manually. IMPORTANT: If you set this parameter to value 4-10, you’ll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice!

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 10 No Yes No

Value

 

Description

0   momentary for lights only
1   toggle switch (light on when the switch is toggled up, light off when the switch is toggled down);
2   toggle switch (state changes whenever the switch is toggled)
3   garage door (momentary mode for Z-Wave control)
4   leak alarm (water sensor)
5   heat alarm
6   motion alert
7   open/close alert (door sensor)
8   CO alarm
9   CO2 alarm
10   on/off report (dry contact switch/sensor)

Parameter Number

Parameter Size

Parameter Name

Description

24 1 DC Motor Mode Sync R1 and R2 together to prevent them from being activated at the same time.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   DC motor mode disabled (relays will activate whenever they're triggered)
1   DC motor mode enabled (relay will check the status of the other relay a􀆞er being triggered and will shut the other relay off before activating so that only one of the relays is on at the same time)

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Input Type for Relay 2 (S2) Choose the wall switch or input type you want to connect to the S2 C terminals. Click twice, holding the Z-Wave button for 5 seconds the second time to change to garage mode manually. IMPORTANT: If you set this parameter to value 4-10, you’ll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice!

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 10 No Yes No

Value

 

Description

0   momentary for lights only
1   toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)
2   toggle switch (state changes whenever the switch is toggled)
3   garage door (momentary mode for Z-Wave control)
4   leak alarm (water sensor)
5   heat alarm
6   motion alert
7   open/close alert (door sensor)
8   CO alarm
9   CO2 alarm
10   on/off report (dry contact switch/sensor)

Parameter Number

Parameter Size

Parameter Name

Description

5 1 LED Indicator Control Choose if you want the LED indicator to turn on when any of the relays are on or if all of them are off, or if you want it to remain on or off at all times.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default);
1   LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off;
2   LED indicator is always OFF;
3   LED indicator is always ON

Parameter Number

Parameter Size

Parameter Name

Description

6 4 Auto Turn-Off Timer for Relay 1 Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 15).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   disabled
1   minutes/seconds/hours

Parameter Number

Parameter Size

Parameter Name

Description

7 4 Auto Turn-On Timer for Relay 1 Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 16).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   disabled
1   minutes/seconds/hours

Parameter Number

Parameter Size

Parameter Name

Description

8 4 Auto Turn-Off Timer for Relay 2 Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 17).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   disabled
1   minutes/seconds/hours

Parameter Number

Parameter Size

Parameter Name

Description

9 4 Auto Turn-On Timer for Relay 2 Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 18).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   disabled
1   minutes/seconds/hours