Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | On Off Status After Power Failure | Set the on off status for the relays after power failure. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 4 | No | No | No |
Value |
Description |
||||
0 | ALL relays forced to OFF (regardless of state prior to power outage) | ||||
1 | ALL relays remember and restore on/off status after power failure (default) | ||||
2 | ALL relays forced to ON (regardless of state prior to power outage) | ||||
3 | Relay 1 remembers and restores on/off status after power failure, Relay 2 forced to ON | ||||
4 | Relay 2 remembers and restores on/off status after power failure, Relay 1 forced to ON. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Input Trigger for Relay 1 | Choose if you’d like the connected input (switch) on S1 C / VC C to trigger the load connected to R1 or if you want to use the input reports for monitoring only and separate the output from the input. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | input trigger disabled | ||||
1 | input trigger enabled (default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Input Trigger for Relay 2 | Choose if you’d like the connected input (switch) on S2 C / VC C to trigger the load connected to R2 or if you want to use the input reports for monitoring only and separate the output from the input. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | input trigger disabled | ||||
1 | input trigger enabled (default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | Auto Turn-Off Timer Unit for Relay 1 | Choose between seconds, minutes, and hours as the unit for the auto turnoff timer for Relay 1. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | minutes | ||||
1 | seconds | ||||
2 | hours | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | Auto Turn-On Timer Unit for Relay 1 | Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 1. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | minutes | ||||
1 | seconds | ||||
2 | hours | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
17 | 1 | Auto Turn-Off Timer Unit for Relay 2 | Choose between seconds, minutes, and hours as the unit for the auto turn off timer for Relay 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | minutes | ||||
1 | seconds | ||||
2 | hours | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | Auto Turn-On Timer Unit for Relay 2 | Choose between seconds, minutes, and hours as the unit for the auto turn on timer for Relay 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | minutes | ||||
1 | seconds | ||||
2 | hours | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Input Type for Relay 1 (S1) | Choose the wall switch or input type you want to connect to the S1 C terminals. Press and hold the Z-Wave button for 5 seconds to change to garage mode manually. IMPORTANT: If you set this parameter to value 4-10, you’ll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice! | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 10 | No | Yes | No |
Value |
Description |
||||
0 | momentary for lights only | ||||
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); | ||||
2 | toggle switch (state changes whenever the switch is toggled) | ||||
3 | garage door (momentary mode for Z-Wave control) | ||||
4 | leak alarm (water sensor) | ||||
5 | heat alarm | ||||
6 | motion alert | ||||
7 | open/close alert (door sensor) | ||||
8 | CO alarm | ||||
9 | CO2 alarm | ||||
10 | on/off report (dry contact switch/sensor) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
24 | 1 | DC Motor Mode | Sync R1 and R2 together to prevent them from being activated at the same time. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | DC motor mode disabled (relays will activate whenever they're triggered) | ||||
1 | DC motor mode enabled (relay will check the status of the other relay aer being triggered and will shut the other relay off before activating so that only one of the relays is on at the same time) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Input Type for Relay 2 (S2) | Choose the wall switch or input type you want to connect to the S2 C terminals. Click twice, holding the Z-Wave button for 5 seconds the second time to change to garage mode manually. IMPORTANT: If you set this parameter to value 4-10, you’ll need to exclude and re-include the device (without changing any settings) so that a child device is created for the input of your choice! | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 10 | No | Yes | No |
Value |
Description |
||||
0 | momentary for lights only | ||||
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) | ||||
2 | toggle switch (state changes whenever the switch is toggled) | ||||
3 | garage door (momentary mode for Z-Wave control) | ||||
4 | leak alarm (water sensor) | ||||
5 | heat alarm | ||||
6 | motion alert | ||||
7 | open/close alert (door sensor) | ||||
8 | CO alarm | ||||
9 | CO2 alarm | ||||
10 | on/off report (dry contact switch/sensor) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | LED Indicator Control | Choose if you want the LED indicator to turn on when any of the relays are on or if all of them are off, or if you want it to remain on or off at all times. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default); | ||||
1 | LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off; | ||||
2 | LED indicator is always OFF; | ||||
3 | LED indicator is always ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 4 | Auto Turn-Off Timer for Relay 1 | Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 15). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | minutes/seconds/hours | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 4 | Auto Turn-On Timer for Relay 1 | Use this parameter to set the time after which you want the device connected to Relay 1 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 16). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | minutes/seconds/hours | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 4 | Auto Turn-Off Timer for Relay 2 | Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 17). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | minutes/seconds/hours | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 4 | Auto Turn-On Timer for Relay 2 | Use this parameter to set the time after which you want the device connected to Relay 2 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in Par. 18). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | disabled | ||||
1 | minutes/seconds/hours | ||||