There are over 4376 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Locally Button function | Parameter=1,Size=1,Value=0 Up Button: On Down Button: Off Value=1 Up Button: Off Down Button: On Value=2 Up Button: On/Off Down Button: On/Off Default = 0 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Up Button ON,Down Button OFF | ||||
1 | Up Button OFF,Down Button ON | ||||
2 | Up Button ON/OFF,Down Button ON/OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Multilevel minimum value can be set | Multilevel minimum value can be set(Local Button)> this should apply to both for local or Z-Wave operation Parameter=10,Size=1,Value=0 disable Value=1 . . Value=99 Default = 1 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | Multilevel minimum value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Multilevel maximum value can be set | Multilevel maximum value can be set(Local Button)> this should apply to both for local or Z-Wave operation Parameter=11,Size=1,Value=0 disable Value=1 . . Value=100 - NOT ACCEPTED BY HUB Default = 99 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
99 | 0 | 100 | No | No | No |
Value |
Description |
||||
0 | Multilevel maximum value can be set | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Double Tap Behavior | Double Tap Behavior: when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness (Local Button) Parameter=12,Size=1, Value = 0 enable double tap to full brightness (99) Value = 1 custom value set in parameter 18 Value = 2 enable double tap to maximum brightness (turn on to the value relate with parameter 11) Value = 3 disable double tap to full brightness Default = 0 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | enable double tap to full brightness (99) | ||||
1 | custom value set in parameter 18 | ||||
2 | enable double tap to maximum brightness (turn on to the value relate with parameter 11) | ||||
3 | disable double tap to full brightness, | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
15 | 1 | Enable or Disable local / Z-Wave control | Enable or Disable local / Z-Wave control Parameter=15,Size=1,Value=0 disable (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status and on/off/multilevel status when paddle is pressed) Value=1 enable (normal operation like now) Value = 2 disable local and Z-Wave control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave control is disabled Default = 1 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | disable (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status and on/off/multilevel status when paddle is pressed) | ||||
1 | enable (normal operation like now) | ||||
2 | disable local and Z-Wave control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave control is disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | dimmer speed | dimmer speed (only for local press & hold): amount of seconds it takes to go from 0 to 100% brightness when pressing and holding the paddle Parameter=16,Size=1, Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s . . Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s Default = 5 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 99 | No | No | No |
Value |
Description |
||||
1 | from 0x63 to 0x00 or from 0x00 to 0x63 need this value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
18 | 1 | Custom brightness level | Custom brightness level - in this parameter define default brightness level the switch will turn on to from main switch or regular switch in 3-way when pressed upper paddle once. Parameter: 18 Size: 1 byte dec Values 0-99 0 - last brightness level 1-99 custom brightness level default = 0 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | last brightness level | ||||
1 | Custom brightness level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
19 | 1 | 3-way switch type | 3-way switch type Parameter=19,Size=1,Value=0 toggle switch(device changes status when switch changes status,it can only turn on or turn off lamp,it can’t dimmer)(default); Value = 1 toggle switch(press 1x change device status;quickly press 2x the result depend on Par11/Par12; quickly Press 3x it trigger dimmer in loop(dimmer up/dimmer down ) Value=2 momentary switch (press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down ) Value=3 momentary switch (press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down – BUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) >> This value is missing, please add to setting Notice: when the value=1,or value=2,the switch can’t respond immediately,because it need to recognize multiple press. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | toggle switch(device changes status when switch changes status) | ||||
1 | toggle switch(press 1x change device status;quickly press 2x the result depend on Par11/Par12; quickly Press 3x it trigger dimmer in loop(dimmer up/dimmer down ) | ||||
2 | momentary switch (press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down ) | ||||
3 | momentary switch (press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down – BUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) >> This value is missing, please add to setting | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | LED Indicator | Parameter=2,Size=1,Value=0 On when Off and Off when On Value=1 On when On and Off when Off Value=2 Always Off Value=3 Always On Default =0 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | On when Off and Off when On | ||||
1 | On when On and Off when Off | ||||
2 | Always OFF | ||||
3 | Always ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
20 | 1 | Association reports | Association reports Parameter=20,Size=1 Values: 0 – Z-Wave control:Multilevel report (without each level,just final level) Manual control (short press): Basic report(without each level,just final level) Manual control(long press & relay enable): Basic report(without each level,just final level) Manual control(long press & relay disable): Multilevel report (each level will be reported) 1 – Z-Wave control:Multilevel report (without each level,just final level) Manual control (short press): Basic report (without each level,just final level) Manual control(long press & relay enable OR disable): Basic report (without each level,just final level) 2 – Z-Wave control:Multilevel report (without each level, just final level) Manual control (short press): Multilevel report (without each level, just final level) Manual control (long press & relay enable): Multilevel report (without each level, just final level) Manual control (long press & relay disable): Multilevel report (each level will be reported) default = 2 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Z-Wave control:Multilevel report (without each level,just final level) Manual control (short press): Basic report(without each level,just final level) Manual control(long press & relay enable): Basic report(without each level,just final level) Manual control(long press & relay disable): Multilevel report (each level will be reported) | ||||
1 | Z-Wave control:Multilevel report (without each level,just final level) Manual control (short press): Basic report (without each level,just final level) Manual control(long press & relay enable OR disable): Basic report (without each level,just final level) | ||||
2 | Z-Wave control:Multilevel report (without each level, just final level) Manual control (short press): Multilevel report (without each level, just final level) Manual control (long press & relay enable): Multilevel report (without each level, just final level) Manual control (long press & relay disable): Multilevel report (each level will be reported) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
21 | 1 | Disabled Relay Behavior | Disabled Relay Behavior Parameter=21,Size=1 Value=0 report on/off and multilevel status when paddle is pressed and change LED indicator status and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20. Value=1 DON’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). Default = 0 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | report on/off and multilevel status when paddle is pressed and change LED indicator status and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20. | ||||
1 | DON’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
22 | 1 | Night Mode Brightness Level | Night Mode Brightness Level Set the level of brightness the dimmer will turn on to when off and lower paddle held DOWN for 2 seconds. Parameter=22,Size=1 Values: 0- disable function; 1-99 % Default:: 20 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
20 | 0 | 99 | No | No | No |
Value |
Description |
||||
0 | Night Mode Brightness Level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
23 | 1 | LED Indicator Color | LED Indicator Color Parameter=23,Size=1,Value=0 White Value=1 Blue Value=2 Green Value=3 Red Default = 1 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | White | ||||
1 | Blue | ||||
2 | Green | ||||
3 | Red | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
24 | 1 | LED Indicator Brightness | LED Indicator Brightness Parameter=24,Size=1,Value=0 Bright (100%) Value=1 Medium (60%) Value=2 Low (30%) Default =1 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Bright (100%) | ||||
1 | Medium (60%) | ||||
2 | Low (30%) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
25 | 1 | Single Tap Behavior | Single Tap Behavior: when switch is off and press UPPER paddle 1 time, switch turns on to x brightness (Local Button) Parameter=25,Size=1, Value = 0 last brightness level Value = 1 custom value set in parameter 18 Value = 2 maximum brightness set in parameter 11 Value = 3 full 100% brightness Default = 0 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | last brightness level | ||||
1 | custom value set in parameter 18 | ||||
2 | maximum brightness set in parameter 11 | ||||
3 | full 100% brightness | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 4 | Auto Turn-Off Timer | Auto Turn-Off Timer--- Values: 0 – 65535 (minutes) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | Auto Turn-Off Timer | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 4 | Auto Turn-On Timer | Auto Turn-On Timer | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | Auto Turn-On this Timer | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Restores state after power failure | Restores state after power failure Parameter=8,Size=1,Value=0 output off Value=1 output on Value=2 out put the state after power Default =2 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Output OFF | ||||
1 | Output ON | ||||
2 | out put the state after power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Ramp rate | Ramp rate(Local Button + Z-Wave)> change to local and Z-Wave like in the latest ZEN30 firmware, also applies to any multilevel changes (so there should be soft transition between 20 and 80% brightness if changed from the hub for example) Parameter=9,Size=1, Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s . . Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s Default = 1 | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 99 | No | No | No |
Value |
Description |
||||
1 | from 0x63 to 0x00 or from 0x00 to 0x63 need this value | ||||