Z-Wave Products

There are over 4376 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Dimmer Switch (MS11ZS)

Z-Wave Certification Number: ZC12-21040209


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Locally Button function Parameter=1,Size=1,Value=0 Up Button: On Down Button: Off Value=1 Up Button: Off Down Button: On Value=2 Up Button: On/Off Down Button: On/Off Default = 0

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 2 No No No

Value

 

Description

0   Up Button ON,Down Button OFF
1   Up Button OFF,Down Button ON
2   Up Button ON/OFF,Down Button ON/OFF

Parameter Number

Parameter Size

Parameter Name

Description

10 1 Multilevel minimum value can be set Multilevel minimum value can be set(Local Button)> this should apply to both for local or Z-Wave operation Parameter=10,Size=1,Value=0 disable Value=1 . . Value=99 Default = 1

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 99 No No No

Value

 

Description

0   Multilevel minimum value

Parameter Number

Parameter Size

Parameter Name

Description

11 1 Multilevel maximum value can be set Multilevel maximum value can be set(Local Button)> this should apply to both for local or Z-Wave operation Parameter=11,Size=1,Value=0 disable Value=1 . . Value=100 - NOT ACCEPTED BY HUB Default = 99

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

99 0 100 No No No

Value

 

Description

0   Multilevel maximum value can be set

Parameter Number

Parameter Size

Parameter Name

Description

12 1 Double Tap Behavior Double Tap Behavior: when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness (Local Button) Parameter=12,Size=1, Value = 0 enable double tap to full brightness (99) Value = 1 custom value set in parameter 18   Value = 2 enable double tap to maximum brightness (turn on to the value relate with parameter 11)   Value = 3 disable double tap to full brightness Default = 0

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   enable double tap to full brightness (99)
1   custom value set in parameter 18
2   enable double tap to maximum brightness (turn on to the value relate with parameter 11)
3   disable double tap to full brightness,

Parameter Number

Parameter Size

Parameter Name

Description

15 1 Enable or Disable local / Z-Wave control Enable or Disable local / Z-Wave control Parameter=15,Size=1,Value=0 disable (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status and on/off/multilevel status when paddle is pressed) Value=1 enable (normal operation like now) Value = 2 disable local and Z-Wave control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave control is disabled Default = 1

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   disable (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave and it will change LED indicator status and on/off/multilevel status when paddle is pressed)
1   enable (normal operation like now)
2   disable local and Z-Wave control (LED and on/off status will still change if paddle pressed) >> make sure that status is still reported and LED indicator changes when Z-Wave control is disabled

Parameter Number

Parameter Size

Parameter Name

Description

16 1 dimmer speed dimmer speed (only for local press & hold): amount of seconds it takes to go from 0 to 100% brightness when pressing and holding the paddle Parameter=16,Size=1, Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s . . Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s Default = 5

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 99 No No No

Value

 

Description

1   from 0x63 to 0x00 or from 0x00 to 0x63 need this value

Parameter Number

Parameter Size

Parameter Name

Description

18 1 Custom brightness level Custom brightness level - in this parameter define default brightness level the switch will turn on to from main switch or regular switch in 3-way when pressed upper paddle once. Parameter: 18 Size: 1 byte dec Values 0-99 0 - last brightness level 1-99 custom brightness level default = 0

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 99 No No No

Value

 

Description

0   last brightness level
1   Custom brightness level

Parameter Number

Parameter Size

Parameter Name

Description

19 1 3-way switch type 3-way switch type Parameter=19,Size=1,Value=0 toggle switch(device changes status when switch changes status,it can only turn on or turn off lamp,it can’t dimmer)(default); Value = 1 toggle switch(press 1x change device status;quickly press 2x the result depend on Par11/Par12; quickly Press 3x it trigger dimmer in loop(dimmer up/dimmer down ) Value=2 momentary switch (press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down ) Value=3 momentary switch (press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down – BUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) >> This value is missing, please add to setting Notice: when the value=1,or value=2,the switch can’t respond immediately,because it need to recognize multiple press.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   toggle switch(device changes status when switch changes status)
1   toggle switch(press 1x change device status;quickly press 2x the result depend on Par11/Par12; quickly Press 3x it trigger dimmer in loop(dimmer up/dimmer down )
2   momentary switch (press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down )
3   momentary switch (press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down – BUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) >> This value is missing, please add to setting

Parameter Number

Parameter Size

Parameter Name

Description

2 1 LED Indicator Parameter=2,Size=1,Value=0 On when Off and Off when On Value=1 On when On and Off when Off Value=2 Always Off Value=3 Always On Default =0

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   On when Off and Off when On
1   On when On and Off when Off
2   Always OFF
3   Always ON

Parameter Number

Parameter Size

Parameter Name

Description

20 1 Association reports Association reports Parameter=20,Size=1 Values: 0 – Z-Wave control:Multilevel report (without each level,just final level) Manual control (short press): Basic report(without each level,just final level) Manual control(long press & relay enable): Basic report(without each level,just final level) Manual control(long press & relay disable): Multilevel report (each level will be reported) 1 – Z-Wave control:Multilevel report (without each level,just final level) Manual control (short press): Basic report (without each level,just final level) Manual control(long press & relay enable OR disable): Basic report (without each level,just final level) 2 – Z-Wave control:Multilevel report (without each level, just final level) Manual control (short press): Multilevel report (without each level, just final level) Manual control (long press & relay enable): Multilevel report (without each level, just final level) Manual control (long press & relay disable): Multilevel report (each level will be reported) default = 2

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   Z-Wave control:Multilevel report (without each level,just final level) Manual control (short press): Basic report(without each level,just final level) Manual control(long press & relay enable): Basic report(without each level,just final level) Manual control(long press & relay disable): Multilevel report (each level will be reported)
1   Z-Wave control:Multilevel report (without each level,just final level) Manual control (short press): Basic report (without each level,just final level) Manual control(long press & relay enable OR disable): Basic report (without each level,just final level)
2   Z-Wave control:Multilevel report (without each level, just final level) Manual control (short press): Multilevel report (without each level, just final level) Manual control (long press & relay enable): Multilevel report (without each level, just final level) Manual control (long press & relay disable): Multilevel report (each level will be reported)

Parameter Number

Parameter Size

Parameter Name

Description

21 1 Disabled Relay Behavior Disabled Relay Behavior Parameter=21,Size=1 Value=0 report on/off and multilevel status when paddle is pressed and change LED indicator status and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20. Value=1 DON’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). Default = 0

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

Value

 

Description

0   report on/off and multilevel status when paddle is pressed and change LED indicator status and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20.
1   DON’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled).

Parameter Number

Parameter Size

Parameter Name

Description

22 1 Night Mode Brightness Level Night Mode Brightness Level Set the level of brightness the dimmer will turn on to when off and lower paddle held DOWN for 2 seconds. Parameter=22,Size=1 Values: 0- disable function; 1-99 % Default:: 20

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 0 99 No No No

Value

 

Description

0   Night Mode Brightness Level

Parameter Number

Parameter Size

Parameter Name

Description

23 1 LED Indicator Color LED Indicator Color Parameter=23,Size=1,Value=0 White Value=1 Blue Value=2 Green Value=3 Red Default = 1

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

Value

 

Description

0   White
1   Blue
2   Green
3   Red

Parameter Number

Parameter Size

Parameter Name

Description

24 1 LED Indicator Brightness LED Indicator Brightness Parameter=24,Size=1,Value=0 Bright (100%) Value=1 Medium (60%) Value=2 Low (30%) Default =1

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No No

Value

 

Description

0   Bright (100%)
1   Medium (60%)
2   Low (30%)

Parameter Number

Parameter Size

Parameter Name

Description

25 1 Single Tap Behavior Single Tap Behavior: when switch is off and press UPPER paddle 1 time, switch turns on to x brightness (Local Button) Parameter=25,Size=1, Value = 0 last brightness level   Value = 1 custom value set in parameter 18   Value = 2 maximum brightness set in parameter 11 Value = 3 full 100% brightness Default = 0

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 3 No No No

Value

 

Description

0   last brightness level
1   custom value set in parameter 18
2   maximum brightness set in parameter 11
3   full 100% brightness

Parameter Number

Parameter Size

Parameter Name

Description

3 4 Auto Turn-Off Timer Auto Turn-Off Timer--- Values: 0 – 65535 (minutes)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   Auto Turn-Off Timer

Parameter Number

Parameter Size

Parameter Name

Description

5 4 Auto Turn-On Timer Auto Turn-On Timer

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 65535 No No No

Value

 

Description

0   Auto Turn-On this Timer

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Restores state after power failure Restores state after power failure Parameter=8,Size=1,Value=0 output off Value=1 output on Value=2 out put the state after power Default =2

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2 0 2 No No No

Value

 

Description

0   Output OFF
1   Output ON
2   out put the state after power

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Ramp rate Ramp rate(Local Button + Z-Wave)> change to local and Z-Wave like in the latest ZEN30 firmware, also applies to any multilevel changes (so there should be soft transition between 20 and 80% brightness if changed from the hub for example) Parameter=9,Size=1, Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s . . Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s Default = 1

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 99 No No No

Value

 

Description

1   from 0x63 to 0x00 or from 0x00 to 0x63 need this value