Z-Wave Products

There are over 3957 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Contact Sensor v2 EU (Contact Sensor v2 EU)

Z-Wave Certification Number: ZC12-21040216


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Heartbeat Interval Heartbeats are automatic battery reports on a timer after the last event.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

70 1 70 No No Yes

Value

 

Description

1   This parameter is the number of minutes between heartbeats.

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Application Retriess Number of application level retries attempted for messages either not ACKed or messages encapsulated via supervision get that did not receive a report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 5 No No Yes

Value

 

Description

0   This parameter is the number of application level retries.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Application Level Retry Base Wait Time Period The number base seconds used in the calculation for sleeping between retry messages.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 96 No No Yes

Value

 

Description

1   This parameter is the number base seconds used in the calculation for sleeping between retry messages.

Parameter Number

Parameter Size

Parameter Name

Description

4 1 LED Indicator Enable This parameter allows a user, via software, to configure the various LED indications on the device. 0 == Don't show green 1 == Show green after Supervision Report Intrusion (Fault) 2 == Show green after Supervision Report both Intrusion and Intrusion clear

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No Yes

Value

 

Description

0   This parameter is used to configure the various LED indications on the device.

Parameter Number

Parameter Size

Parameter Name

Description

5 2 One Shot Timer Writing to this parameter prompts the sensor to send a wakeup notification one time after this parameter's number of seconds. After which it is reset back to 0.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 5 65535 No No Yes

Value

 

Description

5   This parameter prompts the sensor to send a wakeup notification.

Parameter Number

Parameter Size

Parameter Name

Description

6 2 Supervisory Report Timeout The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1500 500 5000 No No Yes

Value

 

Description

500   This parameter is the number of milliseconds waiting for a Supervisory Report response to a Supervisory Get.