Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Range Extender v2 EU (Range Extender v2 EU)

Z-Wave Certification Number: ZC12-21040217


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Hearbeats This parameter is the number minutes between heartbeats. Heartbeats are automatic battery reports on a timer after the last event.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

70 1 70 No No Yes

Value

 

Description

1   This parameter is the number of minutes between heartbeats.

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Application Retries: Number of application level retries attempted for messages either not ACKed or messages encapsulated via supervision get that did not receive a report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 5 No No Yes

Value

 

Description

0   This parameter is the Number of application level retries.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Application Level Retry Base Wait Time Period: The number base seconds used in the calculation for sleeping between retry messages. 

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 60 No No Yes

Value

 

Description

1   This parameter is the number base seconds used in the calculation for sleeping between retry messages. 

Parameter Number

Parameter Size

Parameter Name

Description

4 1 LED Indicator Allows LED indications on the device to be turned on or off

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 2 No No Yes

Value

 

Description

0   This parameter is the LED indications on the device to be turned on or off

Parameter Number

Parameter Size

Parameter Name

Description

5 2 Supervisory Report Timeout The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1500 500 5000 No No Yes

Value

 

Description

500   The number of milliseconds waiting for number of milliseconds waiting for a Supervisory Report response to a Supervisory Get .