There are over 4228 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Q Sensor (ZSE11)

Z-Wave Certification Number: ZC10-21047020


Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Motion Sensitivity 0 disable motion reports
  1 to 8
(Default)
sensitivity levels where 8 is the most sensitive

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Motion Clear Time 10 to 3600
(Default)
seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Basic Set Commands 0 doesn't send basic set commands
  1
(Default)
sends basic set commands

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Basic Set Value 0
(Default)
send 0xFF (ON) when motion is detected and 0x00 (OFF) when motion stops
  1 send 0x00 (OFF) when motion is detected and 0xFF (ON) when motion stops

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 1 Motion Binary Sensor Reports 0 doesn't send binary sensor reports
  1
(Default)
sends binary sensor reports

Parameter Number

Parameter Size

Parameter Name

Parameter Values

172 2 Reporting Frequency 1 to 744
(Default)
hours

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Temperature Scale 1 Celsius
  2
(Default)
Fahrenheit

Parameter Number

Parameter Size

Parameter Name

Parameter Values

182 1 Battery Reporting Threshold 0
(Default)
doesn't report battery based on the reporting threshold
  1 to 99 battery percentage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

183 2 Temperature Reporting Threshold 1 to 144
(Default)
degrees Fahrenheit

Parameter Number

Parameter Size

Parameter Name

Parameter Values

184 1 Humidity Reporting Threshold 0 disable humidity reporting based on environmental changes
  1 to 80
(Default)
percentage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

185 2 Lux Reporting Threshold 0 disable lux reporting based on environmental changes
  1 to 30000
(Default)
lux

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 LED Indicator Mode 0 don’t flash LED when motion is detected
  1
(Default)
flash LED indicator when motion is detected

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 1 Low Battery Alert 10 to 50 battery level percentage