There are over 4376 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 2 | Motion Alarm Retrigger Duration | The duration in seconds that the motion alarm would not be sent since last motion alarm reported. The motion alarm report is enabled only when the duration timer has expired. Range: 10~3600; Default: 240; value = 10 disable motion alarm report. Any valid value that great than 10 enable motion alarm report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
240 | 10 | 3600 | Yes | No | No |
Value |
Description |
||||
10 | Disable motion alarm report | ||||
11 | Enable motion alarm report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Night Light ON Duration | Range: 0~1. Value = 0 Night Light ON for 10 seconds (default). Value = 1 Night Light ON for 30 seconds. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | Yes | No | Yes |
Value |
Description |
||||
0 | Night Light ON for 10 seconds | ||||
1 | Night Light ON for 30 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 1 | Night Light ON based on ambient light level meas | Range: 0~1. Value = 0 Night Light ON only when sense detects total darkness (default). Value = 1 Night Light ON only when a small amount of light is detected. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | Yes | No | Yes |
Value |
Description |
||||
0 | Night Light ON only when sense detects total darkness (default) | ||||
1 | Night Light ON only when a small amount of light is detected | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Enable Tamper Alarm Report | This parameter setting is used to enable/disable the device cover removed Tamper Alarm report. Range: 0~1. Value = 0 - disable the Tamper Alarm report. Value = 1 - enable the Tamper Alarm report. (default) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | Yes | No | Yes |
Value |
Description |
||||
0 | Disable the Tamper Alarm report | ||||
1 | Enable the Tamper Alarm report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Walk Test Mode Duration | This parameter setting is used to set the time out for Walk Test Mode. Range: 0~3. Value = 0 - disable Walk Test Mode; Value = 1 - 10 minutes; Value = 2 = 30 minutes (default); Value = 3 - 60 minutes. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 3 | Yes | No | Yes |
Value |
Description |
||||
0 | Disable Walk Test Mode | ||||
1 | Walk Test Mode 10 minutes | ||||
2 | Walk Test Mode 30 minutes (default) | ||||
3 | Walk Test Mode 60 minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Motion Alarm Retrigger Modes | This option will select how the motion alarm retrigger duration timer (CPN#1) to be reset. Range: 0~1. Value = 0, in this mode, the motion alarm retrigger duration timer (CPN#1) will be reset to zero once the motion event is detected. Hence, the motion alarm retrigger duration timer will start recounting which extends the retrigger duration. This mode will extend the battery life and reduce unnecessary motion alarm reports (default). Value = 1, in this mode, the motion alarm retrigger duration timer (CPN#1) would not be reset once the motion event has detected. The motion alarm reports will be enabled to send once the motion alarm retrigger duration timer has expired. In this mode, it will report the motion alarm event with greater fidelity. This setting might be used where the device will be used for automation tasks. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | Yes | No | Yes |
Value |
Description |
||||
0 | Motion alarm retrigger duration timer (CPN#1) will be reset to zero once the motion event is detected | ||||
1 | Motion alarm retrigger duration timer (CPN#1) would not be reset once the motion event has detected | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 2 | Motion Clear Duration | The period of time in seconds to send motion clear report after motion alarm has reported in Security Mode. Range: 0~3600; Default: 10; value = 0 disable motion clear report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 0 | 3600 | Yes | No | No |
Value |
Description |
||||
0 | Disable motion clear report | ||||
1 | Enable motion clear report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Low battery setting | Report battery low warning message when battery level reaches this value (percentage). Range: 10~50 (10%~50%) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 10 | 50 | Yes | No | No |
Value |
Description |
||||
10 | Low warning message when battery level reaches this value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Battery Scheduled Report Interval | The battery level scheduled report interval time is based on every 30 minutes per kick. The value N related to the time in minutes is N x 30 minutes. Range: 0~120. Default: 12 (12x30 =360 minutes). Value = 0 Disable Battery level scheduled report Battery level scheduled report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
12 | 0 | 120 | Yes | No | Yes |
Value |
Description |
||||
0 | Disable Battery level scheduled report | ||||
1 | N x 30 minute battery level scheduled report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Luminance Change threshold | This parameter determines the change in Lux of light intensity level resulting in sending luminance report. Range: 0~60 (Lux). Default: 50. Value = 0 Disable luminance value scanning, no report. Note: The luminance value is scanned every 5 seconds. A luminance report will be sent if a change over the set threshold value is detected. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 0 | 60 | Yes | No | Yes |
Value |
Description |
||||
0 | Disable luminance value scanning, no report | ||||
1 | Lux luminance value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Temperature Change threshold | This parameter determines the change in temperature value resulting in sending temperature value report. Range: 0~80 (10 = 1.0 °C or °F; 20 = 2.0 °C). Value > 0 and <10 set as 10. Default: 10. Value = 0 Disable temperature value scanning, no report. Note: The temperature value is scanned every 5 minutes. A temperature report will be sent if a change over the set threshold valueis detected. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 0 | 80 | No | No | Yes |
Value |
Description |
||||
0 | No report sent | ||||
11 | Temperature range from 1-80°C | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Temperature Scheduled report interval | The temperature value report interval time is based on 30 minutes per kick. The value N related to the time in minutes is N x 30 minutes. Range: 0~120. Default: 6 (6x30 =180 minutes). Value = 0 Disable temperature scheduled report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 0 | 120 | Yes | No | Yes |
Value |
Description |
||||
0 | Disable temperature scheduled report | ||||
1 | N x 30 minutes temperature scheduled report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Temperature Scale Setting | Option to select the temperature scale type reported in Celsius or Fahrenheit. Range: 0~1. Value = 0 Celsius (C): Value = 1 Fahrenheit (F). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | Yes | No | No |
Value |
Description |
||||
0 | Celsius | ||||
1 | Fahrenheit | ||||