There are over 4407 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | On/Off Toggle Orientation | Choose if you want to turn the light on or turn the light off when you toggle up the switch. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | Toggle up turns the light on, toggle down turns it off (default) | ||||
1 | Toggle up turns the light off, toggle down turns it on | ||||
2 | Toggle any direction to turn the light on/off (change state) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Enable/Disable Scene Control | Enable or disable scene control functionality for quick double tap triggers. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | scene control disabled (default) | ||||
1 | scene control enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | Smart Bulb Mode Behavior | Set reporting behavior for disabled physical control. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | switch reports on/off status and change LED indicator state even if physical and Z-Wave control is disabled (default). | ||||
1 | switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
16 | 1 | Association Reports | Choose how the switch reports its status back to the hub. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
Value |
Description |
||||
0 | Binary switch report for Z-Wave control, basic set report for toggle (physical) control | ||||
1 | binary switch report for both Z-Wave and toggle control (default) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | LED Indicator | Choose how to use the LED indicator. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 3 | No | No | No |
Value |
Description |
||||
0 | LED indicator is on when switch is off, LED indicator is off when switch is on (default) | ||||
1 | LED indicator is on when switch is on, LED indicator is off when switch is off | ||||
2 | LED indicator is always OFF | ||||
3 | LED indicator is always ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 4 | Auto Turn-Off Timer | Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | timer disabled | ||||
1 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 4 | Auto Turn-On Timer | Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 65535 | No | No | No |
Value |
Description |
||||
0 | timer disabled | ||||
1 | minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | On Off Status After Power Failure | Set the on off status for the switch after power failure. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2 | 0 | 2 | No | No | No |
Value |
Description |
||||
0 | forced to OFF (regardless of state prior to power outage | ||||
1 | forced to ON (regardless of state prior to power outage) | ||||
2 | remembers and restores on/off status after power failure (default) | ||||